Siemens 6SL3162-2MA00-0AC0 SINAMICS Booksize C/D Motor Power Connector
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Match the 3 to 30 A Booksize C/D motor-module connection rather than another connector size.
- Use two identical connector variants on a Double Motor Module.
- For the S220 cable assembly, use the specified fine-stranded range, 12 ±0.5 mm strip length and 0.5 to 0.6 Nm terminal torque.
- Keep the motor-phase, protective-earth and brake conductor assignments distinct.
6SL3162-2MA00-0AC0 SINAMICS Booksize C/D Motor Power Connector
The screw-terminal motor plug for Booksize C/D Motor Modules, with connections for motor phases, protective earth and the holding brake.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3162-2MA00-0AC0 |
| Product Type | Motor-cable connection plug |
| Core Function | Connect motor power and holding-brake conductors |
| Application | SINAMICS Booksize C/D Motor Modules |
Screw-terminal version
The MA connector uses screw terminals rather than the MB push-in version.
Motor and brake wiring
U2, V2, W2, protective earth, BR+ and BR− are connected through the plug.
Assembly control
Conductor preparation, ferrules and terminal torque determine the cable assembly.
Product Overview
6SL3162-2MA00-0AC0 provides the screw-terminal power connection for SINAMICS Booksize C/D Motor Modules in the 3 to 30 A class.
The connector accepts the motor phase conductors, protective conductor and holding-brake conductors. The same exact connector article is also specified in the S220 Booksize cable-assembly arrangement.
Key Functions
Connect motor phases and brake
The plug terminates U2, V2 and W2 together with the protective conductor and BR+/BR− holding-brake conductors.
Clamp the prepared conductors
The screw terminals accept the specified fine-stranded conductors and require a tightening torque of 0.5 to 0.6 Nm in the S220 assembly.
Maintain connector consistency
Double Motor Modules require two identical connector variants, using either screw-terminal plugs or push-in plugs throughout.
Official Specifications
| Terminal Technology | Screw terminals |
|---|---|
| Motor Phase Connections | U2, V2 and W2 |
| Holding-Brake Connections | BR+ and BR− |
| Protective Conductor Connection | Included in the motor plug |
| Fine-Stranded Conductor Range, S220 Assembly | 0.75 to 6 mm² (AWG 19 to 10) |
| Terminal Tightening Torque, S220 Assembly | 0.5 to 0.6 Nm |
| Core Strip Length, S220 Assembly | 12 ±0.5 mm |
| Maximum Crimped Ferrule Dimensions | 3.6 × 3.2 mm |
Frequently Asked Questions
Is 6SL3162-2MA00-0AC0 the screw-terminal or push-in connector?
This article is the screw-terminal version, while 6SL3162-2MB00-0AC0 is the push-in version.
Can I mix 6SL3162-2MA00-0AC0 with a push-in plug on one Double Motor Module?
No, a Double Motor Module requires two identical connector variants.
Which motor-cable conductors connect through 6SL3162-2MA00-0AC0?
The plug connects U2, V2, W2, the protective conductor and the BR+/BR− holding-brake conductors.
What terminal torque applies to 6SL3162-2MA00-0AC0 in the S220 cable assembly?
Tighten the conductor terminals to 0.5 to 0.6 Nm.
How much insulation should I remove from each core for 6SL3162-2MA00-0AC0 in the S220 assembly?
The specified core strip length is 12 mm with a tolerance of ±0.5 mm.
Can I fabricate a 10 mm² motor cable using 6SL3162-2MA00-0AC0 in the S220 arrangement?
No, that arrangement requires preassembled MOTION-CONNECT power cables for 10 mm² conductors.
What size limit applies to a crimped ferrule inserted in 6SL3162-2MA00-0AC0?
The crimped ferrule must not exceed 3.6 × 3.2 mm.