Overview

SIEMENS SINAMICS TM15

6SL3055-0AA00-3FA0 SINAMICS TM15 Terminal Module

Add 24 individually configurable digital inputs or outputs to a drive system through DRIVE-CLiQ, with three isolated groups and local status LEDs.

At a Glance

Brand Siemens
Model 6SL3055-0AA00-3FA0
Product Type Digital I/O expansion module
Core Function Expand drive-system field signals
Application DRIVE-CLiQ drive and motion-control systems

Configurable direction

Each of the 24 channels is parameterized separately as a digital input or output.

DRIVE-CLiQ connection

Two sockets integrate the terminal module into the drive communication topology.

Cabinet installation

The housing mounts on a TH35 rail and provides plug-in screw terminals.

Product Overview

6SL3055-0AA00-3FA0 expands the digital signal connections of a SINAMICS drive system. Its 24 bidirectional channels are electrically isolated in three groups of eight, allowing the required mix of machine inputs and actuator outputs to be defined in parameters.

Two DRIVE-CLiQ sockets connect the terminal module to the drive system, while per-channel LEDs display the logical signal state and a multicolor module LED indicates operating status.

Ordering focus: Plan the channel directions and the group load currents, and order the DRIVE-CLiQ cable separately for this article.
Key Functions

Allocate the required mix of digital signals

Every channel can be assigned independently as DI or DO, providing a configurable terminal interface for the machine.

Connect to the drive communication chain

Two DRIVE-CLiQ sockets support module integration and onward connection within the permitted drive topology.

Observe field states during commissioning

Twenty-four green channel LEDs and a multicolor module-status LED help locate active signals and module conditions.

Official Specifications
Channel Configuration 24 bidirectional digital channels, individually parameterizable as DI or DO
Electrical Grouping 3 isolated groups of 8 channels
DRIVE-CLiQ Sockets 2
Electronics Supply Voltage 24 V DC; permitted range 20.4 to 28.8 V DC
Electronics Current Consumption 0.15 A without DRIVE-CLiQ or digital-output loads
Maximum Power Dissipation 3 W
Digital Input Voltage Range −30 to +30 V DC
Input Logic Levels LOW: −30 to +5 V; HIGH: 15 to 30 V
Typical Hardware Input Delays 50 µs rising; 100 µs falling
Digital Output Rating 24 V DC; maximum 0.5 A per channel
Group Output-Current Limits 4 A at 40 °C; 3 A at 50 °C; 2 A at 60 °C
Maximum Field-Signal Cable Length 30 m
Signal Terminal Connection Plug-in screw terminals; maximum conductor cross-section 1.5 mm²
Supply Conductor and Fuse Limits Maximum conductor cross-section 2.5 mm²; maximum fuse protection 20 A
Protective-Conductor Connection M4 screw
Ambient Operating Temperature 0 to 60 °C up to 2000 m altitude
Permitted Relative Humidity 5 to 95%, without condensation
Dimensions 50 × 150 × 111 mm (W × H × D)
Frequently Asked Questions

Can I mix digital inputs and outputs freely on 6SL3055-0AA00-3FA0?

Yes, each of the 24 channels can be parameterized independently as a digital input or output.

Does 6SL3055-0AA00-3FA0 support DRIVE-CLiQ connection for mobile equipment?

No, this article is supplied without a DRIVE-CLiQ cable.

How should I load an output group of 6SL3055-0AA00-3FA0 at 50 °C?

Limit the total current of that group to 3 A while keeping each output within its 0.5 A rating.

What happens to an open digital input on 6SL3055-0AA00-3FA0?

An open digital input is interpreted as a LOW signal.

Can I extend the field-signal cables from 6SL3055-0AA00-3FA0 beyond 30 m?

No, the maximum permitted digital I/O cable length is 30 m.

How do I mount 6SL3055-0AA00-3FA0 inside the control cabinet?

Snap the module onto a TH35 standard mounting rail and connect the protective conductor to the M4 housing connection.

Can the cable-shield clamp on 6SL3055-0AA00-3FA0 also provide strain relief?

No, the shield connection terminal must not be used as a strain-relief mechanism.

Compatibility & Ordering Notes
Before ordering 6SL3055-0AA00-3FA0: Select the DRIVE-CLiQ cable, 24 V supply wiring and signal terminals for the planned topology, then calculate the output current in each group at the cabinet operating temperature.

Compatibility Checklist for 6SL3055-0AA00-3FA0

  • Match the configured DI and DO directions to the field wiring.
  • Keep all output-group currents within the temperature-dependent limits.
  • Connect the protective conductor and provide separate signal-cable strain relief.
  • Include the DRIVE-CLiQ cable and any unused-port blanking plugs in the accessory plan.
Hot Selling Models
116237 H44NP
1N4007/RL
35N 1040400000
E20748 FT-11-EPA-M4/F2X0.5/FH/2M
CDQSB25-10D
FKS-44-423
ABB LX460 1SFN075710R1000
R060030800
DR 10190000
2DOR 8 312225
051-303-203
CAD50BL 040696
6SL3055-0AA00-4BA0
VMPA2FBEMG4
M22-R*1K-* 263371

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.