Siemens 6SE6420-2AB11-2AA1 MICROMASTER 420 0.12 kW Frequency Inverter
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Match the single-phase line supply and three-phase motor circuit to the drive ratings.
- Keep the continuous motor current within the 0.9 A high-overload rating.
- Provide the required overload recovery interval for repetitive duty.
- Install the fan-cooled IP20 FSA unit in an appropriately protected space.
6SE6420-2AB11-2AA1 MICROMASTER 420 0.12 kW Frequency Inverter
A 0.12 kW high-overload inverter with single-phase input, three-phase motor output and a compact frame-size A housing.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE6420-2AB11-2AA1 |
| Product Type | Compact variable-speed drive |
| Core Function | Adjust AC motor speed |
| Application | Low-power three-phase motor circuits |
Single-phase power conversion
The drive accepts a 200–240 V single-phase line input with ±10% tolerance and provides a three-phase motor output.
Low-power overload duty
The high-overload rating is 0.12 kW with a 0.9 A rated output and a 150% current capability for 60 seconds in the specified cycle.
Flexible command and feedback
One analog input, one analog output, three digital inputs and one relay output support compact machine control.
Product Overview
6SE6420-2AB11-2AA1 converts a single-phase line supply into a controlled three-phase motor output for a 0.12 kW high-overload application.
A 0.9 A rated output and 16 kHz pulse frequency distinguish this variant, while the onboard I/O allows discrete and analog integration.
Key Functions
Single-phase power conversion
The drive accepts a 200–240 V single-phase line input with ±10% tolerance and provides a three-phase motor output.
Low-power overload duty
The high-overload rating is 0.12 kW with a 0.9 A rated output and a 150% current capability for 60 seconds in the specified cycle.
Flexible command and feedback
One analog input, one analog output, three digital inputs and one relay output support compact machine control.
Official Specifications
| Line input | 1 AC, 200–240 V ±10% |
|---|---|
| Line frequency | 47–63 Hz |
| Rated input current, HO | 1.80 A |
| Output phases and rated voltage | 3 AC; 240 V |
| Rated motor power, HO | 0.12 kW / 0.16 hp |
| Rated output current, HO | 0.90 A |
| Overload sequence | 150% current for 60 s, then 100% for 240 s per 300 s cycle |
| Pulse frequency | 16 kHz |
| Digital command connections | 3 digital inputs |
| Relay signaling | 1 relay output |
| Analog channels | 1 input and 1 output |
| Operating ambient, HO | −10 to +50 °C |
| Storage and transport ambient | −40 to +70 °C |
| Cooling | Fan |
| Enclosure and frame size | IP20 / UL open type; FSA |
| Motor terminal conductor capacity | 2.50 mm² |
| Physical dimensions | 73 × 173 × 149 mm |
| Net weight | 1.00 kg |
Frequently Asked Questions
Does 6SE6420-2AB11-2AA1 require a three-phase mains connection?
It accepts a single-phase 200–240 V supply with a ±10% tolerance.
Can 6SE6420-2AB11-2AA1 supply a three-phase motor from that single-phase input?
The inverter provides a three-phase output with a rated voltage of 240 V.
Is 6SE6420-2AB11-2AA1 sized for a 1 A motor under its rated high-overload duty?
Its rated high-overload output current is 0.9 A.
Which pulse frequency does 6SE6420-2AB11-2AA1 use?
The specified pulse frequency is 16 kHz.
Can I return a discrete status signal from 6SE6420-2AB11-2AA1 to a PLC?
One relay output is available for discrete signaling.
How much panel space should I allow for the body of 6SE6420-2AB11-2AA1?
The drive body measures 73 mm wide, 173 mm high and 149 mm deep.
What recovery interval follows a 60-second overload on 6SE6420-2AB11-2AA1?
The overload cycle requires a further 240 seconds at 100% current after the 60-second 150% interval.