Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6gk7443 5dx05 0xe0 simatic net cp 443 5 extended profibus communication processor-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC NET CP 443-5 Extended PROFIBUS Communication Processor 6GK7443-5DX05-0XE0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMATIC NET S7-400

6GK7443-5DX05-0XE0 SIMATIC NET CP 443-5 Extended PROFIBUS Communication Processor

The CP 443-5 Extended is a SIMATIC NET communication processor for connecting an S7-400 station to PROFIBUS DP with additional S7, PG/OP and S5-compatible services.

At a Glance

Brand Siemens
Model 6GK7443-5DX05-0XE0
Product Type CP 443-5 Extended PROFIBUS communication processor
Core Function Connects an S7-400 controller to PROFIBUS DP and industrial communication services
Application or Compatible Series SIMATIC S7-400 systems requiring DP master, S7, PG/OP or S5-compatible communication

Exact Identification

Match 6GK7443-5DX05-0XE0 character by character and confirm the complete SIMATIC NET CP 443-5 Extended PROFIBUS Communication Processor designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The CP 443-5 Extended is a SIMATIC NET communication processor for connecting an S7-400 station to PROFIBUS DP with additional S7, PG/OP and S5-compatible services.

The processor supports DPV1 communication with as many as 125 distributed slaves. S7 communication, PG/OP functions and S5-compatible open communication can operate through the same module. Supported PROFIBUS transmission rates extend from 9.6 kbit/s to 12 Mbit/s.

Ordering focus: confirm the complete CP article number, S7-400 rack compatibility, PROFIBUS address and rate, DP slave configuration and programmed communication services.

Key Functions

PROFIBUS DP Master Operation

The processor supports DPV1 communication with as many as 125 distributed slaves.

Multiple Communication Services

S7 communication, PG/OP functions and S5-compatible open communication can operate through the same module.

Wide Bus-Speed Range

Supported PROFIBUS transmission rates extend from 9.6 kbit/s to 12 Mbit/s.

Official Specifications
PROFIBUS Transmission Rates 9.6 kbit/s to 12 Mbit/s
PROFIBUS Connector 9-pin D-sub, RS485
PROFIBUS Profile DPV1
Maximum DP Slaves 125
Total DP Input Area 4096 bytes
Total DP Output Area 4096 bytes
Input Data per DP Slave 244 bytes maximum
Output Data per DP Slave 244 bytes maximum
Maximum S7 Connections 48
Open-Communication Connections 32
Open-Communication Data per Connection 240 bytes
Backplane Supply 5 V DC, ±5%
Typical Current Consumption 0.6 A
Typical Power Loss 3 W
Operating Temperature 0 to 60 °C
Storage and Transport Temperature -40 to 70 °C
Maximum Relative Humidity 95%
Degree of Protection IP20
Dimensions 25 × 290 × 210 mm
Approximate Weight 0.65 kg

Frequently Asked Questions

How many PROFIBUS slaves can 6GK7443-5DX05-0XE0 control?

A configured DP master system can include as many as 125 slaves.

Which PROFIBUS connector is used by 6GK7443-5DX05-0XE0?

The bus interface uses a 9-pin D-sub connector with an RS485 physical layer.

What PROFIBUS speeds are supported by 6GK7443-5DX05-0XE0?

The interface supports standard rates from 9.6 kbit/s through 12 Mbit/s.

Can 6GK7443-5DX05-0XE0 carry S7 and PG/OP communication?

Yes, it supports S7 communication and programming-device or operator-panel services.

Does 6GK7443-5DX05-0XE0 support DPV1 functions?

Yes, the communication processor supports the DPV1 profile.

What environmental protection does 6GK7443-5DX05-0XE0 provide?

The module is rated IP20 and must be installed in the appropriate protected enclosure.

What should be preserved before replacing 6GK7443-5DX05-0XE0?

Save the STEP 7 project, bus address, transmission rate, slave configuration and configured communication connections.

Compatibility & Ordering Notes
Before ordering 6GK7443-5DX05-0XE0: confirm the complete CP article number, S7-400 rack compatibility, PROFIBUS address and rate, DP slave configuration and programmed communication services.

Compatibility Checklist

  • Use the communication processor in a compatible SIMATIC S7-400 central rack.
  • Match the PROFIBUS cable, connector, address and transmission rate to the installed network.
  • Restore the complete hardware and communication configuration from the verified STEP 7 project.

Hot Selling Models
Z00-1.6
09320
3TF4222-0B
6ES7368-3BB01-0AA
P1-25 SP1-025
ABB 1SDA066311R1
700-321-1BH02
6ES5420-7LA11
ABB AL9-30-01
ABB 1SVR405651R1000
PKZM0-6.3 NHI11-PKZ0
5SY62 MCB C10 5SY6210-7
5SY4206-7 5SY42 5ST3010 5ST301.AS
5SY62 MCB C6 5SY6206-7
5SY6213-6MCBB13

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.