Overview
- Confirm the controller is a compatible SIMATIC S7-300 or C7-300 station.
- Record the installed hardware release and firmware version before exchanging the module.
- Preserve the PROFIBUS address, transmission rate and DP master or DP device role.
- Verify DP_SEND, DP_RECV and any SEND/RECEIVE blocks used by the CPU program.
- Use STEP 7 V5.1 SP2 or a compatible later release with the required hardware catalog entry.
- Provide the external 24 V DC supply and check available backplane current.
- Do not download changed bus parameters through the same PROFIBUS connection being reconfigured.
Siemens · SIMATIC NET CP 300
6GK7342-5DA02-0XE0 CP 342-5 PROFIBUS Communication Processor
Siemens identifies this CP 342-5 as the S7-300 communication processor with an electrical RS485 PROFIBUS interface. The module supports DP master or DP device operation together with S5-compatible SEND/RECEIVE, PG/OP and S7 communication services configured in STEP 7.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GK7342-5DA02-0XE0 |
| Product Type | PROFIBUS Communication Processor |
| Core Function | Offloads network communication between an S7-300 CPU and a PROFIBUS fieldbus |
| Application or Compatible Series | SIMATIC S7-300 and C7-300 controller stations |
Firmware and Project Match
Record the installed hardware release, firmware version, STEP 7 configuration and communication-block versions before replacement.
Bus Configuration
Preserve the PROFIBUS address, baud rate, DP operating role, connected stations and termination arrangement.
CPU Interface
Verify the S7-300 rack slot, 24 V field supply, backplane loading and DP_SEND or DP_RECV program interface.
Product Overview
Siemens identifies this CP 342-5 as the S7-300 communication processor with an electrical RS485 PROFIBUS interface. The module supports DP master or DP device operation together with S5-compatible SEND/RECEIVE, PG/OP and S7 communication services configured in STEP 7.
The processor can operate as a DP master or DP device on an electrical RS485 PROFIBUS network. It supports programming-device, operator-panel, S7 and S5-compatible FDL communication paths. The module executes the PROFIBUS exchange while DP_SEND and DP_RECV coordinate cyclic data with the S7-300 CPU.
Key Functions
PROFIBUS DP Operation
The processor can operate as a DP master or DP device on an electrical RS485 PROFIBUS network.
PLC Communication Services
It supports programming-device, operator-panel, S7 and S5-compatible FDL communication paths.
CPU-Independent Bus Handling
The module executes the PROFIBUS exchange while DP_SEND and DP_RECV coordinate cyclic data with the S7-300 CPU.
Official Specifications
| Supported Transmission Rates | 9.6, 19.2, 45.45, 93.75 and 187.5 kbit/s; 500 kbit/s; 1.5, 3, 6 and 12 Mbit/s |
|---|---|
| PROFIBUS Connection | 1 x 9-pin D-sub socket using RS485 |
| Power Connection | 1 x 4-pole terminal block |
| Supply Voltages | 5 V DC from the backplane bus and external 24 V DC with +20% / -15% tolerance |
| Typical Current Consumption | 0.15 A from the 5 V backplane bus and 0.25 A from the external 24 V supply |
| Power Dissipation | 5 W |
| Operating Temperature | 0 to +60 deg C |
| Storage and Transport Temperature | -40 to +70 deg C |
| Humidity and Protection | 95% maximum at 25 deg C without condensation; IP20 |
| Module Physical Data | Single-width S7-300 compact module; 40 x 125 x 120 mm; 0.3 kg; S7-300 rail mounting |
| Maximum Modules per CPU | 4 |
| Open-Communication Connections | 16 maximum through SEND/RECEIVE blocks |
| Open-Communication Payload | 240 bytes maximum user data per connection |
| DP Master Capacity | DPV0 with up to 124 usable DP slaves |
| DP Master Total Address Space | 2160 bytes of inputs and 2160 bytes of outputs |
| Per-Slave DP Address Space | 244 bytes of inputs, 244 bytes of outputs and 240 bytes of diagnostic data |
| DP Device Capacity | DPV0 with 240 bytes of inputs and 240 bytes of outputs; DPV1 not available |
| S7 Communication Connections | 16 maximum |
| Multi-Protocol Active Connections | 32 maximum without DP or 28 maximum with DP |
| Required Configuration Software | STEP 7 V5.1 SP2 or higher |
Frequently Asked Questions
Which STEP 7 release can configure 6GK7342-5DA02-0XE0?
Use STEP 7 V5.1 SP2 or a later compatible release for project engineering.
Where can I install 6GK7342-5DA02-0XE0 in an S7-300 rack?
The processor can occupy one of the standard I/O positions from slot 4 through slot 11.
Which PROFIBUS rates can 6GK7342-5DA02-0XE0 use?
The electrical interface supports the standard rates from 9.6 kbit/s through 12 Mbit/s.
Which blocks exchange DP data with the CPU through 6GK7342-5DA02-0XE0?
Use DP_SEND and DP_RECV to transfer the process data between the communication processor and the CPU.
Can 6GK7342-5DA02-0XE0 be used for PROFIBUS FMS communication?
The processor supports PROFIBUS DP and FDL services but not PROFIBUS FMS.
What power connections are required for 6GK7342-5DA02-0XE0?
Provide 24 V DC to the external supply terminals while the module also draws current from the S7-300 backplane bus.
What should I preserve when replacing 6GK7342-5DA02-0XE0 with a later CP 342-5?
Preserve the project configuration, communication-block interface, firmware-dependent behavior, bus parameters and stored configuration strategy.