Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6gk5612 0ba00 2aa3 scalance s612 industrial security module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6GK5612-0BA00-2AA3 SCALANCE S612 Industrial Security Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SCALANCE S

6GK5612-0BA00-2AA3 SCALANCE S612 Industrial Security Module

A two-port industrial security module with stateful firewall inspection, IPsec connections and optional removable configuration storage.

At a Glance

Brand Siemens
Model 6GK5612-0BA00-2AA3
Product Type Industrial network security appliance
Core Function Separating automation networks and protecting communication
Application Internal and external industrial Ethernet networks

Network separation

Dedicated internal and external RJ45 connections define the protected network boundary.

VPN and packet inspection

IPsec connectivity and stateful inspection provide the configured communication protection.

Configuration and operating diagnostics

SCT configuration, optional C-PLUG storage and multiple log facilities support maintenance.

Product Overview

6GK5612-0BA00-2AA3 separates an automation network from an external Ethernet connection.

Stateful inspection, IPsec communication and configurable routing and address translation support the network arrangement, with logging and a signaling contact for operating diagnostics.

Ordering focus: Match the internal and external network topology, bridge or routing mode, VPN capacity and redundant DC supply arrangement.
Key Functions

Network separation

Dedicated internal and external RJ45 connections define the protected network boundary.

VPN and packet inspection

IPsec connectivity and stateful inspection provide the configured communication protection.

Configuration and operating diagnostics

SCT configuration, optional C-PLUG storage and multiple log facilities support maintenance.

Official Specifications
Ethernet connections One internal and one external RJ45 port
Link rates 10 or 100 Mbit/s
Firewall type Stateful inspection
VPN protocol IPsec
Maximum VPN connections 64
Protected network size in bridge mode Maximum 32 internal nodes; this node limit does not apply in routing mode
VPN authentication Preshared key or X.509v3 certificates
Address services Static IP routing, NAT/NAPT and internal-network DHCP server
Supply voltage 24 V DC nominal; permissible range 20.4–28.8 V
Maximum supply current 0.25 A
Rated power loss 3.84 W
Supply connections Four-pole terminal block with redundant voltage input
Input fuse Non-replaceable F 3 A / 32 V melting fuse
Signaling contact Two-pole terminal block; 24 V DC, maximum 0.1 A
Removable configuration medium Optional C-PLUG
Diagnostic logging SysLog, packet-filter log, audit log and system log
Time functions NTP and battery-backed hardware real-time clock
Operating environment 0–60 °C; maximum 95% RH at 25 °C without condensation
Storage and enclosure protection −40 to +80 °C; IP30
Dimensions and net mass 60 × 125 × 124 mm; 0.78 kg
Frequently Asked Questions

Does the 32-node figure for 6GK5612-0BA00-2AA3 also limit a routed internal network?

The 32-node limit applies only in bridge mode and does not apply in routing mode.

Does 6GK5612-0BA00-2AA3 have separate connectors for the protected and external networks?

One RJ45 port serves the internal network and one serves the external network.

Can 6GK5612-0BA00-2AA3 accept a redundant DC power source?

A redundant voltage-supply connection is provided.

Can the input fuse inside 6GK5612-0BA00-2AA3 be replaced as an ordinary maintenance item?

The specified input melting fuse is non-replaceable.

Can I use removable configuration storage with 6GK5612-0BA00-2AA3?

The module supports an optional C-PLUG.

Which configuration tool is supplied for 6GK5612-0BA00-2AA3?

The Security Configuration Tool is included for configuration.

Can the DHCP server in 6GK5612-0BA00-2AA3 serve its internal network?

The DHCP server function is provided for the internal network.

Compatibility & Ordering Notes
Before ordering 6GK5612-0BA00-2AA3: Match the internal and external network topology, bridge or routing mode, VPN capacity and redundant DC supply arrangement.

Before installation

  • Assign the internal and external ports according to the planned protected-network boundary.
  • Select bridge or routing mode with the applicable internal-node limit.
  • Configure the required IPsec authentication, packet filtering and address-translation functions in SCT.
  • Use the specified DC supply arrangement and the required mounting and environmental conditions.
Hot Selling Models
3TF4022-0AM0
MBS EASK 61.4 600/5A
2717016
DWMA-400-1-0-000
3TH8280-0A
3RT1026-1BB40
DIM50
CXM2015
440K-C21088
EMF2111IB 00409551
YA35B051
WD150
KDIMCM8SUB92.5
TB-P2/20273743 QP-0110-0075-0551/698521
T275 900670

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.