Siemens SIMATIC PCS 7 ET 200PA SMART AO 8x12 Bit 6ES7650-8BK60-0AA0
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SIMATIC PCS 7 ET 200PA SMART
6ES7650-8BK60-0AA0 SIMATIC PCS 7 ET 200PA SMART AO 8x12 Bit Analog Output Module
The Siemens ET 200PA SMART AO 8x12 Bit module provides eight isolated analog outputs for voltage or current control signals in process automation systems.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7650-8BK60-0AA0 |
| Product Type | Eight-channel isolated analog output module |
| Core Function | Generates configurable voltage or current signals for eight process output channels, including HART current operation |
| Application or Compatible Series | ET 200PA SMART distributed I/O stations equipped with an IM 650-8PH interface module |
Exact Identification
Match the complete article number and the AO 8x12 Bit designation before replacing an installed module.
Signal Configuration
Confirm every channel range, load type and two-wire or four-wire field connection before commissioning.
Station Compatibility
Use the module in an ET 200PA SMART station with the required IM 650-8PH interface module.
Product Overview
The Siemens ET 200PA SMART AO 8x12 Bit module provides eight isolated analog outputs for voltage or current control signals in process automation systems.
Eight channels in one group can be assigned to the specified voltage or current ranges for process actuators. Current outputs are HART-compliant, while configurable diagnostics and diagnostic interrupts support maintenance. The module provides galvanic isolation from the backplane and load supply with selectable redundancy for current outputs.
Key Functions
Eight Configurable Outputs
Eight channels in one group can be assigned to the specified voltage or current ranges for process actuators.
HART and Diagnostics
Current outputs are HART-compliant, while configurable diagnostics and diagnostic interrupts support maintenance.
Process-Ready Electrical Design
The module provides galvanic isolation from the backplane and load supply with selectable redundancy for current outputs.
Official Specifications
| Output Channels | 8 channels in one group |
|---|---|
| Current Output Ranges | 0 to 20 mA; 4 to 20 mA; ±20 mA |
| Voltage Output Ranges | 1 to 5 V; 0 to 10 V; ±10 V |
| Digital Resolution | 12 bit; 11 bit plus sign for bipolar ranges and selected unipolar ranges |
| HART Operation | HART-compliant on current outputs |
| Maximum Conversion Time per Channel | 0.8 ms |
| Rated Load Voltage | 24 V DC with reverse-polarity protection |
| Maximum Backplane Current | 100 mA |
| Maximum L+ Supply Current | 340 mA |
| Typical Power Loss | 6.0 W |
| Maximum Shielded Cable Length | 200 m |
| Voltage Output Load | Minimum 1 kΩ; maximum capacitive load 1 µF |
| Current Output Load | Maximum 500 Ω; maximum inductive load 10 mH |
| Maximum Voltage Short-Circuit Current | 25 mA |
| Maximum Current No-Load Voltage | 18 V |
| Isolation Test Voltage | 500 V DC |
| Redundant Operation | Available for current output with identical modules |
| Front Connector | 40-pole; four-wire voltage and two-wire current connections |
| Dimensions (W × H × D) | 40 × 125 × 117 mm |
| Approximate Weight | 272 g |
Frequently Asked Questions
Which station interface is required for 6ES7650-8BK60-0AA0?
Install it in an ET 200PA SMART station that uses the IM 650-8PH interface module.
Can 6ES7650-8BK60-0AA0 provide both voltage and current outputs?
Each channel can be configured for one of the specified voltage or current ranges.
Does 6ES7650-8BK60-0AA0 support HART devices?
HART communication is available when a channel is operated as a current output.
How should loads be checked before connecting 6ES7650-8BK60-0AA0?
Verify that resistance, capacitance and inductance remain within the limits for the selected output type.
Can 6ES7650-8BK60-0AA0 be used in a redundant output arrangement?
Redundant operation is available for current outputs when two identical modules are configured together.
What wiring format applies to 6ES7650-8BK60-0AA0?
Use the 40-pole front connector with four-wire voltage connections or two-wire current connections as required.
What should be restored after replacing 6ES7650-8BK60-0AA0?
Restore the channel ranges, diagnostics, HART settings, addresses and field wiring assignments before returning the station to service.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm the installed station is an ET 200PA SMART system with an IM 650-8PH interface module.
- Match every field load to the configured voltage or current range and permitted electrical limits.
- Restore the original channel parameters, diagnostics, addresses and HART settings before process commissioning.