Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7422 1ff00 0aa0 sm 422 8 do 120 230 v ac 5 a-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7422-1FF00-0AA0 SM 422 8 DO 120/230 V AC 5 A

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC S7-400 AC output modules

6ES7422-1FF00-0AA0 SM 422 8 DO 120/230 V AC 5 A

An eight-channel AC output module with individually isolated 5 A outputs, channel fuses and status indication.

At a Glance

Brand Siemens
Model 6ES7422-1FF00-0AA0
Product Type AC actuator output electronics
Core Function Switch isolated load circuits
Application S7-400 automation racks

Individual channel isolation

Each output is isolated from the other channels and from the backplane bus.

AC load switching

A 10 mA to 5 A permitted on-state load range supports AC actuators within the specified switching-frequency limits.

Serviceable output protection

Each output is protected by an 8 A, 250 V fuse and has a green status LED.

Product Overview

6ES7422-1FF00-0AA0 switches eight 120/230 V AC load circuits in an S7-400 rack, with electrical isolation in groups of one channel.

Each output has an 8 A fuse, while separate INTF and EXTF indicators distinguish an internal fuse fault from missing load voltage.

Ordering focus: Select the eight-channel 5 A version and check AC load voltage, minimum load current and the module total-current limit.
Key Functions

Individual channel isolation

Each output is isolated from the other channels and from the backplane bus.

AC load switching

A 10 mA to 5 A permitted on-state load range supports AC actuators within the specified switching-frequency limits.

Serviceable output protection

Each output is protected by an 8 A, 250 V fuse and has a green status LED.

Official Specifications
Output channel count 8, isolated in groups of 1
Rated load voltage 120/230 V AC
Permitted load voltage and frequency 79–264 V AC; 47–63 Hz
On-state output current 10 mA–5 A per channel
Maximum off-state residual current 3.5 mA
Maximum combined output current 24 A up to 40 °C; 16 A up to 60 °C without fan, 20 A with fan
Maximum output delay 1 AC cycle for each switching direction with resistive load
Maximum lamp load 100 W
Maximum switching frequency Resistive: 10 Hz; inductive: 0.5 Hz; lamp: 1 Hz
Maximum actuator cable length 600 m unshielded; 1,000 m shielded
Maximum backplane current at 5 V 250 mA
Typical module power loss 16 W
Permitted potential difference between groups 500 V AC
Insulation strength 4,000 V AC
Output short-circuit protection 8 A, 250 V fuse per output
Fault indication INTF red for fuse failure; EXTF red for missing load voltage
Channel indication Green LED per output
Parallel output connection Permitted for redundant control of the same load
Dimensions 25 × 290 × 210 mm
Approximate mass 800 g
Frequently Asked Questions

Can I switch separate AC load circuits with 6ES7422-1FF00-0AA0?

The eight outputs are individually isolated in groups of one channel.

Will a 5 mA indicator operate within the load range of 6ES7422-1FF00-0AA0?

The permitted on-state current begins at 10 mA.

What should I inspect when the INTF LED lights on 6ES7422-1FF00-0AA0?

The red INTF indication identifies an output fuse failure.

Why is the EXTF indicator lit on 6ES7422-1FF00-0AA0?

The red EXTF indication signals that load voltage is missing.

Can I connect two outputs of 6ES7422-1FF00-0AA0 redundantly?

Redundant parallel control is possible when both outputs are connected to the same load.

Can all outputs of 6ES7422-1FF00-0AA0 carry 5 A continuously at 60 °C?

The combined output current at 60 °C is limited to 16 A without a fan module or 20 A with one.

What must I remove before changing an output fuse in 6ES7422-1FF00-0AA0?

Remove the front connector before changing a fuse.

Compatibility & Ordering Notes
Before ordering 6ES7422-1FF00-0AA0: Select the eight-channel 5 A version and check AC load voltage, minimum load current and the module total-current limit.

Before installation

  • Use AC loads within 79–264 V and 47–63 Hz.
  • Observe the 10 mA minimum load and the ambient-dependent combined-current limit.
  • Use the specified quick-response 8 A replacement fuse.
  • Remove the front connector before fuse replacement and retain the individual channel wiring.
Hot Selling Models
MOD31X01808006
8TX-NF 2891022
MOD1/1X778-028 TDM1.2-100-300-W1
LSNG-100 031745
64E/32A 6FC3984-3RA
3NA3805
8045647 8I/OM12-5P3T
P1M-2NK/24V
O2D220 02DIRPKG/K
1710250000
3UF7010-1AB00-0
6ES5741-0AB1
M122053002
P1MO
7000-12221-6340500

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop