Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7412 2xg00 0ab0 simatic s7 400 cpu 412 2-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S7-400 6ES7412-2XG00-0AB0 CPU 412-2

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-400

6ES7412-2XG00-0AB0 CPU 412-2 Central Processing Unit

Siemens 6ES7412-2XG00-0AB0 is a SIMATIC S7-400 CPU 412-2 central processing unit with separate 72 KB code and 72 KB data work-memory areas. It provides one integrated MPI/PROFIBUS DP interface and one additional integrated PROFIBUS DP interface for controller, engineering and distributed-I/O communication. This XG00 hardware generation is specified with firmware V3.1 and engineering from STEP 7 V5.2. Later CPU 412-2 order numbers such as XG04, XJ05 and XK07 belong to different firmware and performance generations, so replacement requires a project, memory-card, communication and rack-power review rather than suffix substitution.

At a Glance

Brand Siemens
Model 6ES7412-2XG00-0AB0
Product Type Modular Programmable Logic Controller CPU
Core Function Executes the automation program and coordinates central and distributed process I/O
Application or Compatible Series SIMATIC S7-400 automation systems

Exact CPU Generation

Match the complete XG00 suffix and firmware V3.1 because later CPU 412-2 revisions have different order numbers and resources.

Project and Memory Baseline

Archive the STEP 7 project and record the installed FLASH or RAM memory card before removing the CPU.

Network and Rack Check

Record both interface roles, PROFIBUS addresses, baud rates, slave configuration and S7-400 rack power loading.

Product Overview

Siemens 6ES7412-2XG00-0AB0 is a SIMATIC S7-400 CPU 412-2 central processing unit with separate 72 KB code and 72 KB data work-memory areas. It provides one integrated MPI/PROFIBUS DP interface and one additional integrated PROFIBUS DP interface for controller, engineering and distributed-I/O communication. This XG00 hardware generation is specified with firmware V3.1 and engineering from STEP 7 V5.2. Later CPU 412-2 order numbers such as XG04, XJ05 and XK07 belong to different firmware and performance generations, so replacement requires a project, memory-card, communication and rack-power review rather than suffix substitution.

Combines an MPI/DP port with a second dedicated DP port, both using isolated RS485 physical layers. Provides independent 72 KB work-memory areas for code and data plus integrated RAM load memory. Executes bit, word and fixed-point operations from 0.2 microseconds and floating-point operations from 0.6 microseconds.

Ordering focus: Confirm the complete XG00 suffix, CPU firmware, STEP 7 project version, installed memory-card type and capacity, rack power reserve, X1 MPI/DP role, X2 DP role, bus addresses and connected stations before ordering.

Key Functions

Dual Integrated PROFIBUS Interfaces

Combines an MPI/DP port with a second dedicated DP port, both using isolated RS485 physical layers.

Separated Program and Data Memory

Provides independent 72 KB work-memory areas for code and data plus integrated RAM load memory.

Deterministic S7-400 Processing

Executes bit, word and fixed-point operations from 0.2 microseconds and floating-point operations from 0.6 microseconds.

Official Specifications

Firmware Version V3.1
Engineering Software STEP 7 V5.2 or higher
Integrated Work Memory 72 KB for code and 72 KB for data
Integrated Load Memory 256 KB RAM
Memory Card Expansion Up to 64 MB FLASH or up to 64 MB RAM
Bit, Word and Fixed-Point Operation Time Minimum 0.2 microseconds
Floating-Point Operation Time Minimum 0.6 microseconds
Available S7 Counters and Timers 256 counters and 256 timers
Total I/O Address Area 4 KB inputs and 4 KB outputs
Configurable Process Image Up to 4 KB inputs and 4 KB outputs; preset 128 bytes each
Partial Process Images Maximum 8
Maximum Consistent Data 244 bytes
Digital Channel Capacity 32768 inputs and 32768 outputs
Analog Channel Capacity 2048 inputs and 2048 outputs
Integrated Communication Ports One MPI/DP and one PROFIBUS DP interface; isolated RS485; up to 12 Mbit/s
S7 Connection Resources 16 across integrated interfaces and communication processors
Backplane Current at 5 V DC Typically 1.5 A; maximum 1.6 A
Power Loss Typically 7.5 W
Mounting Size and Slot Requirement 25 x 290 x 219 mm; one S7-400 slot
Approximate Weight 0.72 kg

Frequently Asked Questions

Which STEP 7 version should I use for 6ES7412-2XG00-0AB0?

Use STEP 7 V5.2 or a later release that still supports this CPU generation and firmware.

How much work memory is available in 6ES7412-2XG00-0AB0?

The CPU provides 72 KB for code and a separate 72 KB area for data.

Which network interfaces are built into 6ES7412-2XG00-0AB0?

The first isolated RS485 interface can operate as MPI or PROFIBUS DP, while the second isolated RS485 interface is for PROFIBUS DP.

Can I replace 6ES7412-2XG00-0AB0 directly with an XG04, XJ05 or XK07 CPU?

No, treat each later suffix as a different hardware and firmware generation and validate the project, memory card, interfaces and supported functions before migration.

Which memory card capacity can I use with 6ES7412-2XG00-0AB0?

The load memory can be expanded with a FLASH or RAM memory card up to 64 MB.

What rack-power values should I check for 6ES7412-2XG00-0AB0?

Allow for approximately 1.5 A and no more than 1.6 A from the 5 V S7-400 backplane, with typical power loss of 7.5 W.

What should I save before replacing 6ES7412-2XG00-0AB0?

Save the complete STEP 7 project and record the firmware, memory-card type, rack slot, interface modes, bus addresses, transmission rates and connected DP stations.

Compatibility & Ordering Notes

Before ordering 6ES7412-2XG00-0AB0: Confirm the complete XG00 suffix, CPU firmware, STEP 7 project version, installed memory-card type and capacity, rack power reserve, X1 MPI/DP role, X2 DP role, bus addresses and connected stations before ordering.

Compatibility Checklist

  • Use the CPU only in a compatible SIMATIC S7-400 rack with a suitable system power supply.
  • Engineer the exact XG00 hardware generation from STEP 7 V5.2 or a later release that retains support for it.
  • Match the installed CPU firmware because Siemens communication-processor compatibility tables distinguish V3.0, V3.1 and V3.1.3 states.
  • Preserve the X1 MPI/DP and X2 PROFIBUS DP operating modes, addresses and transmission rates.
  • Keep each PROFIBUS segment at or below the 12 Mbit/s interface limit.
  • Confirm the FLASH or RAM memory-card type and do not exceed 64 MB.
  • Check the 5 V backplane current budget against the typical 1.5 A and maximum 1.6 A CPU demand.
  • Verify every attached communication processor against the exact CPU firmware using the applicable Siemens compatibility table.
  • Do not transfer performance or memory values from the XG04, XJ05 or XK07 successors to this XG00 execution.
  • Restore and test the archived project, DP configuration and process-image assignments before returning the system to service.
Hot Selling Models
Allen-Bradley 1492-CB1G010
WAGO 750-603
LR-QS4-D-7-Micro
1059660000
Allen-Bradley 1734-OB4E
DA11 026464
ABB S202 B6 2CDS252001R0065
1200660376 884031K05M010
AMGFIM-0EX 2082530000
Siemens 3RV2411-1JA10
SDSE-1 0608830143
EMT6
V1U2.2
41.52.9.110.0010
9901461007

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.