Overview

Siemens · SIMATIC S7-300 / ET 200M Ex I/O

6ES7331-7SF00-0AB0 SM 331 Ex Analog Input Module

Siemens 6ES7331-7SF00-0AB0 is an isolated SM 331 analog input module for temperature measurements originating in hazardous areas, with configuration for eight thermocouples or four supported resistance thermometers.

At a Glance

Brand Siemens
Model 6ES7331-7SF00-0AB0
Product Type SM 331 Ex Analog Input Module
Core Function Acquires intrinsically safe temperature signals with channel diagnostics
Application or Compatible Series SIMATIC S7-300 and ET 200M Ex I/O stations

Sensor Selection

Match every configured input to the required thermocouple or resistance-thermometer characteristic before wiring the hazardous-area circuit.

Conversion Setup

Select integration time, resolution and interference-frequency rejection as one coordinated measurement setting.

Intrinsic-Safety Check

Calculate the connected circuit against the module limits for voltage, current, power, capacitance and inductance before commissioning.

Product Overview

Siemens 6ES7331-7SF00-0AB0 is an isolated SM 331 analog input module for temperature measurements originating in hazardous areas, with configuration for eight thermocouples or four supported resistance thermometers.

The module processes up to eight thermocouple signals or four supported resistance-temperature measurements. Four integration-time and resolution combinations balance conversion speed against interference rejection. Readable diagnostics identify overrange, broken sensor conductors and signal-cable short circuits.

Ordering focus: confirm the exact article number, approved S7-300 or ET 200M Ex configuration, 20-pole front connector, sensor characteristic, integration setting, shielding and complete intrinsic-safety loop calculation.

Key Functions

Multi-Sensor Temperature Acquisition

The module processes up to eight thermocouple signals or four supported resistance-temperature measurements.

Selectable Measurement Performance

Four integration-time and resolution combinations balance conversion speed against interference rejection.

Channel-Oriented Fault Detection

Readable diagnostics identify overrange, broken sensor conductors and signal-cable short circuits.

Official Specifications

Rated Load Voltage 24 V DC
Backplane-Bus Current at 5 V DC 120 mA maximum
Typical Power Loss 0.6 W
Input Configuration 8 thermocouple inputs or 4 resistance-thermometer inputs
Voltage Measuring Ranges ±25 mV, ±50 mV, ±80 mV, ±250 mV, ±500 mV and ±1 V
Thermocouple Characteristics Types B, E, J, K, L, N, R, S, T and U with 10 MΩ input resistance
Resistance-Thermometer Characteristics Ni100, Pt100 and Pt200 with 10 MΩ input resistance
Maximum Shielded Cable Length 200 m; 50 m for thermocouples
Measurement Principle Sigma-delta conversion
Parameterizable Integration Times 2.5 ms, 16.67 ms, 20 ms and 100 ms
Basic Conversion Times 7.5 ms, 50 ms, 60 ms and 300 ms, each plus 2.5 ms optomultiplexer recovery time
Additional Wire-Break Detection Time 2.5 ms
Resolution Settings 9 bits plus sign, 12 bits plus sign, or 15 bits plus sign according to the selected integration time
Interference-Frequency Rejection 400 Hz, 60 Hz, 50 Hz or 10 Hz according to the selected integration setting
Common-Mode Rejection Greater than 130 dB with UISO below 60 V
Normal-Mode Rejection Greater than 40 dB
Crosstalk Attenuation Greater than 70 dB with UISO below 60 V
Maximum Error Voltage 60 V DC or 30 V AC
Intrinsically Safe Output Limits Uo 5.9 V, Io 28.8 mA and Po 41.4 mW
Gas Group IIC External Limits Co 43 µF and Lo 40 mH

Frequently Asked Questions

Can 6ES7331-7SF00-0AB0 measure both thermocouples and resistance thermometers?

The module can be configured for up to eight thermocouples or four supported resistance thermometers.

Which thermocouple families can I connect to 6ES7331-7SF00-0AB0?

The available characteristics include types B, E, J, K, L, N, R, S, T and U.

How should I select the integration time for 6ES7331-7SF00-0AB0?

Choose the setting that provides the required conversion speed, resolution and rejection of the site interference frequency.

Can 6ES7331-7SF00-0AB0 detect a broken temperature-sensor cable?

The channel diagnostics include wire-break detection with an additional 2.5 ms conversion interval.

What cable length can I use with 6ES7331-7SF00-0AB0?

Shielded runs may reach 200 m, while thermocouple runs are limited to 50 m.

Are the channels of 6ES7331-7SF00-0AB0 isolated from one another?

The channels are not mutually isolated, although the analog inputs are isolated from the backplane bus.

What must I calculate before connecting an Ex circuit to 6ES7331-7SF00-0AB0?

The field circuit must remain within the applicable no-load voltage, short-circuit current, output power, external capacitance and external inductance limits.

Compatibility & Ordering Notes

Before ordering 6ES7331-7SF00-0AB0: confirm the exact article number, approved S7-300 or ET 200M Ex configuration, 20-pole front connector, sensor characteristic, integration setting, shielding and complete intrinsic-safety loop calculation.

Compatibility Checklist

  • Confirm an S7-300 or ET 200M configuration approved for the required Ex application.
  • Provide the correct 20-pole front connector.
  • Match every channel to the configured thermocouple or resistance-thermometer characteristic.
  • Apply the 50 m thermocouple cable limit and the approved shielding arrangement.
  • Select integration time and interference frequency as a matched pair.
  • Validate the complete intrinsic-safety loop against Uo, Io, Po, Co and Lo.
  • Allow for a shared channel potential group because the channels are not isolated from each other.
Hot Selling Models
U539
3RU1126-1FD0
3RU1126-1KD0
ABB 1SDA062164R1
5SY4108-8
CA2KN40F72
18314000100
3TH4310-0A
CA20.T203/D-A025.EF AT18F52038/600
7000-88021-6300250
7000-89501-2400500
6ES5410-7AA11
CA3KN223BD
6es5712-8af00
6EP3332-6SB00-0AY0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.