Overview
SIEMENS SIMATIC ET 200SP

6ES7193-6PA00-0AA0 ET 200SP Server Module

A 7 mm wide ET 200SP bus-end module with slot-voltage status functions and a holder for three spare 5 × 20 mm fuses.

At a Glance

Brand Siemens
Model 6ES7193-6PA00-0AA0
Product Type ET 200SP server module
Core Function Closes the station backplane bus and provides configured slot-voltage status data
Application Termination and status supervision of ET 200SP stations

Backplane bus completion

The server module closes the ET 200SP backplane bus.

Slot status information

Configured input data represents supply and supported feedback-voltage status.

Spare fuse holder

A built-in support stores three spare 5 × 20 mm fuses.

Product Overview

6ES7193-6PA00-0AA0 completes the ET 200SP backplane bus and supports configured monitoring of the I/O modules’ supply-voltage and feedback-voltage states.

The compact module supports firmware updates, I&M identification data and reconfiguration in RUN, with a holder for three spare fuses and retentive device-name storage for supported IM 155-6 PN BA replacement arrangements.

Ordering focus: Match the ET 200SP CPU or interface module, intended status-data configuration and required firmware level for IM 155-6 PN BA device-name retention.
Key Functions

Backplane bus completion

The server module closes off the ET 200SP backplane bus at the end of the station.

Supply and feedback-voltage status

Configured input data reports missing supply voltage or absent I/O modules and, where supported by the I/O module, feedback voltage.

Service and replacement support

The module provides I&M data and firmware updating, while product version 1 with firmware V1.1.1 or later supports retentive device-name storage for IM 155-6 PN BA replacement without topological configuration.

Official Specifications
Maximum current consumption 30 mA
Mounting rail height 7.5 mm or 15 mm
Horizontal-installation operating temperature −30 to +60 °C
Vertical-installation operating temperature −30 to +50 °C
Maximum installation altitude 5,000 m; installation restrictions apply above 2,000 m
Minimum dew point −60 °C; suitable for dry-room applications
Dimensions (W × H × D) 7 × 117 × 36 mm
Approximate weight 19 g
Spare fuse holder Three fuses, 5 × 20 mm
Input data for supply-voltage status only 2, 4 or 8 bytes for CPU/interface maximum configurations of 12, 32 or 64 I/O slots respectively
Input data for supply- and feedback-voltage status 4, 8 or 16 bytes for CPU/interface maximum configurations of 12, 32 or 64 I/O slots respectively
Feedback-voltage detection threshold I/O module L+ greater than 6 V, with supported feedback monitoring
IM 155-6 PN BA device-name retention requirement Server module product version ≥1 and firmware ≥V1.1.1
Frequently Asked Questions

Where does 6ES7193-6PA00-0AA0 belong in the ET 200SP station?

The server module closes the backplane bus at the end of the ET 200SP station.

What fuse size can be stored in 6ES7193-6PA00-0AA0?

The integrated holder accommodates three spare fuses measuring 5 × 20 mm.

Which version of 6ES7193-6PA00-0AA0 supports device-name retention for IM 155-6 PN BA replacement?

This function requires product version 1 or later with firmware V1.1.1 or later.

How many input bytes does 6ES7193-6PA00-0AA0 need for both voltage-status functions in a 32-slot configuration?

A CPU or interface module with a maximum configuration of 32 I/O modules uses eight input bytes when both supply-voltage and feedback-voltage status are enabled.

Can 6ES7193-6PA00-0AA0 evaluate feedback voltage from every ET 200SP I/O module?

The I/O module must support feedback-voltage monitoring for that status to be evaluated.

Which engineering methods can configure 6ES7193-6PA00-0AA0?

The module can be configured with STEP 7 in TIA Portal or with a GSD file.

Is the full 60 °C upper ambient limit valid for a vertical installation of 6ES7193-6PA00-0AA0?

The upper limit is 60 °C for horizontal installation and 50 °C for vertical installation, with a lower limit of −30 °C in both orientations.

Compatibility & Ordering Notes
Before ordering 6ES7193-6PA00-0AA0: Select the server module for the ET 200SP station end and match the CPU or interface-module configuration, enabled status functions and firmware-dependent replacement features.

Compatibility Checklist for 6ES7193-6PA00-0AA0

  • Install at the ET 200SP backplane-bus end.
  • Use a mounting rail with a supported 7.5 mm or 15 mm height.
  • Choose the supply and feedback-voltage status configuration and allocate its input bytes.
  • Use I/O modules with the required monitoring capability.
  • Use product version ≥1 and firmware ≥V1.1.1 for the IM 155-6 PN BA device-name retention function.
  • Observe orientation-specific temperatures and altitude restrictions.
Hot Selling Models
H07V-K
6ES5497-4UB42
CBX100 93A301067
WTE11-2P2432 1041381 1748
22-S-M8-PNP
EL2622
A-5003-7306
NBB8-F33-E2
1-KAB 176-2 1-CON-P3001
BR-090.03,540,UR
1784180000
6ES7134-0HF01-0XB0
SPAB-B2R-G18-PB-M8
Helukabel 26497
FES-M-11

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.