Siemens 6ES7157-0AF81-0XA0 AFD Active Field Distributor

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIMATIC DP/PA Link · PROFIBUS PA

6ES7157-0AF81-0XA0 AFD Active Field Distributor

Four-spur active field distributor for PROFIBUS PA field devices in a redundant PA ring.

At a Glance

Brand Siemens
Model 6ES7157-0AF81-0XA0
Product Type Active field distributor
Core Function Connects up to four PROFIBUS PA field devices to a PA main line
Compatible Series SIMATIC DP/PA Link / FDC 157-0

Four PA spur lines

Connect up to four certified PROFIBUS PA field devices through X1–X4.

Ring redundancy

Works with two FDC 157-0 DP/PA couplers to support a redundant PA ring.

On-device diagnostics

LEDs indicate PA main-line and spur-line status or faults.

Product Overview

6ES7157-0AF81-0XA0 is a Siemens AFD active field distributor for PROFIBUS PA installations. It provides four spur connections for PA field devices and two PA main-line connections.

The AFD operates in a PA segment with FDC 157-0 couplers and supports ring-redundant architectures. Confirm the installed product version before applying enclosure ratings.

Ordering focus: Match the existing FDC 157-0/PA ring design, product version, cable glands and four field-device spur loads.
Key Functions

Four protected spur connections

X1–X4 connect PROFIBUS PA instruments and support up to 60 mA per spur.

Redundant PA line operation

Two FDC 157-0 couplers and AFD devices can form a ring for improved segment availability.

Local indication

Green and red LEDs provide main-line and spur-line operating or fault indication.

Official Specifications
Siemens article number 6ES7157-0AF81-0XA0
Product designation Active field distributor (AFD)
Application PROFIBUS PA field-device distribution
PA main-line connections 2 (PA1 and PA2)
PA spur-line connections 4 (X1–X4)
Maximum PA field devices 4 per AFD
Maximum current per PA spur 60 mA
Rated supply voltage 16–32 V DC via PA line
Maximum supply voltage 35 V
Polarity reversal protection Yes
Internal current consumption Max. 25 mA; 59 mA with open main line
Protection class, version 02 IP65
Protection class, version 01 IP66
Terminal technology, version 02 Screw terminals
Terminal technology, version 01 Spring-clamp terminals
Dimensions, enclosure 125 × 57 × 80 mm
Dimensions with screw glands 175 × 57 × 105 mm
Approximate weight 700 g
Main-line status indication Green LEDs for PA1 and PA2
Main-line fault indication Red LEDs for PA1 and PA2
Spur status/fault indication Green LEDs for X1–X4
Frequently Asked Questions

What does 6ES7157-0AF81-0XA0 distribute?

It connects the PROFIBUS PA main line to as many as four certified PA field devices through spur lines X1–X4.

How many PA instruments can 6ES7157-0AF81-0XA0 connect?

The AFD connects up to four PA field devices, one on each spur.

What current limit applies to each spur on 6ES7157-0AF81-0XA0?

Each PA spur line has a 60 mA maximum current.

Can 6ES7157-0AF81-0XA0 be used in a redundant PA ring?

Yes, the AFD supports ring redundancy with two FDC 157-0 DP/PA couplers.

How is 6ES7157-0AF81-0XA0 powered?

The distributor receives 16–32 V DC through the PA line without a separate auxiliary supply.

How do the enclosure versions of 6ES7157-0AF81-0XA0 differ?

Check the installed version because version 01 has IP66 protection with spring clamps, whereas version 02 has IP65 protection with screw terminals.

Which indicators on 6ES7157-0AF81-0XA0 support fault finding?

LEDs report PA1/PA2 main-line status and faults and X1–X4 spur status or faults.

Compatibility & Ordering Notes
Before ordering 6ES7157-0AF81-0XA0: Verify the AFD product version, PA segment design, FDC 157-0 couplers and field-device current requirements before replacing an installed distributor.

Installation checks

  • Confirm the PA segment uses the intended FDC 157-0 coupler and ring topology.
  • Count no more than four connected PA field devices per AFD.
  • Check each spur load against the 60 mA limit.
  • Match IP rating, terminal technology, cable glands and grounding to the installed product version.
Hot Selling Models
IN1801A3
MOD 275
CAD11.A220/D-A006.KN1 AT20F53109/200
3RT1034-1BB44 3RH1921-1HA22
8/3-2A 2754972
23004200.035 OT050P075D/N04B2-AP OT050
SAC-2P-M12MSB/10.0-910/M12FSB
01289.003
S1MS
2BP210.4
ZF/F/10s/1Uz1SzFBM
ABB F204 A 2CSF204101R1250
NM02AG-MC2069
WS12-D4381 2013727
MS420001

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.