- Use a PROFIBUS DP controller and an appropriate nine-pin Sub-D bus connector.
- Keep the configured station within 63 modules and 2 m width.
- Budget input and output data separately against the 244-byte limits.
- Include the terminating module at the end of the ET 200S assembly.
6ES7151-1AA04-0AB0 IM151-1 Standard ET 200S Interface Module
A PROFIBUS DP V0/V1 interface for up to 63 ET 200S peripheral modules, with 244 bytes available in each process-data direction.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7151-1AA04-0AB0 |
| Product Type | Distributed I/O bus interface |
| Core Function | Connect a station to PROFIBUS DP |
| Application | ET 200S peripheral stations |
PROFIBUS station connection
The RS485 interface supports DP V0 and V1 communication at rates up to 12 Mbit/s.
Wide station assembly
Up to 63 peripheral modules can be connected across a station width of up to 2 m.
Bus and supply indication
BF, SF and ON LEDs expose bus faults, group faults and the 24 V supply state at the station.
Product Overview
6ES7151-1AA04-0AB0 links an ET 200S peripheral station to PROFIBUS through a nine-pin Sub-D socket.
It accommodates a station width of up to 2 m and supports SYNC, FREEZE and direct slave-to-slave data exchange; a terminating module is included.
Key Functions
PROFIBUS station connection
The RS485 interface supports DP V0 and V1 communication at rates up to 12 Mbit/s.
Wide station assembly
Up to 63 peripheral modules can be connected across a station width of up to 2 m.
Bus and supply indication
BF, SF and ON LEDs expose bus faults, group faults and the 24 V supply state at the station.
Official Specifications
| Peripheral module capacity | Maximum 63 modules |
|---|---|
| Maximum station width | 2 m |
| Process-data allocation | 244 input bytes and 244 output bytes |
| Bus connection | 9-pin Sub-D socket, RS485 |
| Maximum communication rate | 12 Mbit/s |
| Maximum PROFIBUS cable length | 1,200 m |
| Maximum supply current at 1L+ | 200 mA |
| Mains-failure buffering | 20 ms |
| Typical power loss | 3.3 W |
| Maximum interface output current | 80 mA |
| DP synchronization services | SYNC and FREEZE |
| Direct slave-to-slave exchange | Supported |
| Isochronous operation | Not supported |
| Diagnostics LEDs | BF red, SF red and ON green |
| Electrical isolation | PROFIBUS isolated from electronics; no backplane-to-electronics isolation |
| Isolation test voltage | 500 V DC |
| Dimensions | 45 × 119.5 × 75 mm |
| Approximate mass | 150 g |
Frequently Asked Questions
Can I connect 6ES7151-1AA04-0AB0 directly to a PROFINET IO controller?
The interface supports PROFIBUS DP rather than PROFINET IO.
How large can an ET 200S station built around 6ES7151-1AA04-0AB0 become?
The station can contain up to 63 peripheral modules within a maximum width of 2 m.
Does 6ES7151-1AA04-0AB0 provide 244 bytes shared between inputs and outputs?
It provides a separate 244-byte allocation for inputs and another 244-byte allocation for outputs.
Which bus connector mates with 6ES7151-1AA04-0AB0?
Use the nine-pin Sub-D PROFIBUS connection for its RS485 interface.
Can I use 6ES7151-1AA04-0AB0 for clock-synchronous operation?
Isochronous mode is not supported by this interface.
How can I distinguish a bus fault from a supply indication on 6ES7151-1AA04-0AB0?
The red BF LED indicates a bus fault while the green ON LED monitors the 24 V supply.
Do I need to source the station terminating module separately with 6ES7151-1AA04-0AB0?
A terminating module is included with the interface module.