siemens 6es7138 4fb04 0ab0 simatic et 200s 4 f do profisafe output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7138-4FB04-0AB0 SIMATIC ET 200S 4 F-DO PROFIsafe Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200S

6ES7138-4FB04-0AB0 SIMATIC ET 200S 4 F-DO PROFIsafe Output Module

A four-channel transistor output module with paired current-sourcing and current-sinking switching, diagnostics and safety-system integration.

At a Glance

Brand Siemens
Model 6ES7138-4FB04-0AB0
Product Type Fail-safe digital output module
Core Function Safety-related load switching
Application PROFIsafe distributed I/O stations

Fail-safe output control

Four digital outputs support configured safety operation up to PL e and SIL 3.

Fault detection

Wire-break and short-circuit diagnostics support field-circuit troubleshooting.

Distributed safety integration

The module can also operate in a PROFINET configuration with the IM 151-3 HF interface.

Product Overview

6ES7138-4FB04-0AB0 switches safety-related field loads in a configured ET 200S PROFIsafe station.

The module combines output-status and group-fault indication with wire-break and short-circuit diagnostics, subject to the permitted per-channel and total-load limits.

Ordering focus: Match the fail-safe station configuration, terminal module, output loads and mounting-dependent current limits.
Key Functions

Fail-safe output control

Four digital outputs support configured safety operation up to PL e and SIL 3.

Fault detection

Wire-break and short-circuit diagnostics support field-circuit troubleshooting.

Distributed safety integration

The module can also operate in a PROFINET configuration with the IM 151-3 HF interface.

Official Specifications
Nominal load supply 24 V DC; no reverse-polarity protection
Output channels 4 transistor outputs
Nominal output current 2 A per channel
Permitted signal-one current 20 mA–2.4 A
Maximum module current 6 A
Horizontal total-current limits 6 A up to 40 °C; 5 A up to 55 °C; 4 A up to 60 °C
Vertical total-current limit 4 A up to 40 °C
Load-resistance range 12 Ω–1 kΩ
Maximum lamp load 10 W
Maximum switching rates 30 Hz resistive, 0.1 Hz inductive, 10 Hz lamp load; symmetrical switching
Maximum output cable length 500 m, shielded or unshielded
Typical no-load current 100 mA from the load supply
Maximum backplane current 28 mA at 3.3 V DC
Typical power loss 3.5 W
Safety capability Up to PL e, ISO 13849-1; SIL 3, IEC 61508
Channel-to-backplane isolation Provided; no isolation between individual channels
Dimensions 30 × 81 × 52 mm (W × H × D)
Approximate weight 85 g
Frequently Asked Questions

Can 6ES7138-4FB04-0AB0 be used in a PROFINET-based ET 200S safety station?

The module supports a PROFINET configuration with the IM 151-3 HF interface.

Can all four outputs of 6ES7138-4FB04-0AB0 continuously carry 2 A at the same time?

The total current must remain within the module limit of 6 A and the applicable mounting-temperature limit.

What total output current is permitted for 6ES7138-4FB04-0AB0 when mounted horizontally at 55 °C?

The horizontal-installation total-current limit is 5 A up to 55 °C.

Can I parallel two channels of 6ES7138-4FB04-0AB0 to increase current capacity?

Parallel output connection is not permitted for increasing current or redundant load control.

Will 6ES7138-4FB04-0AB0 diagnose an open load wire?

The module provides wire-break diagnostics.

Can 6ES7138-4FB04-0AB0 be used to drive a digital input directly?

The outputs are not specified for controlling a digital input.

What is the smallest permitted on-state load current for 6ES7138-4FB04-0AB0?

The minimum permissible signal-one load current is 20 mA.

Compatibility & Ordering Notes
Before ordering 6ES7138-4FB04-0AB0: Match the fail-safe station configuration, terminal module, output loads and mounting-dependent current limits.

Before installation

  • Use the module only in the corresponding configured fail-safe station and safety application.
  • Select loads within the per-channel current and resistance ranges.
  • Observe total-current limits for the actual mounting direction and temperature.
  • Do not parallel outputs and protect the supply wiring against incorrect polarity.
Hot Selling Models
8223076.18
TL-X5F1-M1-E2
efector100 IF5492 - IFK3004-ANOG/US-100-DNS
6ES7142-4BF00-0AA0
3RT2016-1BB42-1AA0
3RG7201-3CC00
Z4VH 335-11z-M20
MCR-S5/U/I-0
LAS8 / PLC 08379451600
10750FIL + P8S-GPCHX
VAA-4A-KF-E2
ABB AF12-30-22-11
7700-A5A01-U1D0030
030-3000-12
NT15

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.