Siemens 6ES7138-4FB04-0AB0 SIMATIC ET 200S 4 F-DO Modulus extrationis PROFIsafe
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use the module only in the corresponding configured fail-safe station and safety application.
- Select loads within the per-channel current and resistance ranges.
- Observe total-current limits for the actual mounting direction and temperature.
- Do not parallel outputs and protect the supply wiring against incorrect polarity.
6ES7138-4FB04-0AB0 SIMATIC ET 200S 4 F-DO PROFIsafe Output Module
A four-channel transistor output module with paired current-sourcing and current-sinking switching, diagnostics and safety-system integration.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7138-4FB04-0AB0 |
| Typus Producti | Modulus digitalis outputus tutus |
| Functio principalis | Safety-related load switching |
| Applicatio | PROFIsafe distributed I/O stations |
Controllo output fail-safe
Four digital outputs support configured safety operation up to PL e and SIL 3.
Delectio culpae
Wire-break and short-circuit diagnostics support field-circuit troubleshooting.
Distributed safety integration
The module can also operate in a PROFINET configuration with the IM 151-3 HF interface.
Product Overview
6ES7138-4FB04-0AB0 switches safety-related field loads in a configured ET 200S PROFIsafe station.
Modulus combinat indicatio status output et fault group cum diagnostics pro wire-break et short-circuit, sub conditionibus limitum per channel et totalis load permittarum.
Key Functions
Controllo output fail-safe
Four digital outputs support configured safety operation up to PL e and SIL 3.
Delectio culpae
Wire-break and short-circuit diagnostics support field-circuit troubleshooting.
Distributed safety integration
The module can also operate in a PROFINET configuration with the IM 151-3 HF interface.
Official Specifications
| Alimentazione carico nominale | 24 V DC; nullum protectio contra reverse polarity |
|---|---|
| Output channels | 4 transistor outputs |
| Nominale Exitus Current | 2 A per canalium |
| Current permittus pro signallo uno | 20 mA–2.4 A |
| Maxima currentis modulus | 6 A |
| Limites horizontalis currentis totalis | 6 A usque ad 40 °C; 5 A usque ad 55 °C; 4 A usque ad 60 °C |
| Limites verticalis currentis totalis | 4 A usque ad 40 °C |
| Intervallo resistentiae oneris | 12 Ω–1 kΩ |
| Maxima onus lampadis | 10 W |
| Rationes commutationis maximae | 30 Hz resistivum, 0.1 Hz inductivum, 10 Hz pro onere lampae; commutatio symmetricalis |
| Longitudo Maxima Cavi Exientis | 500 m, scutumatum aut non scutumatum |
| Typical No-Load Current | 100 mA ab supply oneris |
| Currentis Maxima Planae Posterioris | 28 mA ad 3.3 V DC |
| Perditio potentiæ typica | 3.5 W |
| Capacitas Securitatis | Usque ad PL e, ISO 13849-1; SIL 3, IEC 61508 |
| Isolatio canalis ad bus dorsalem | Praebetur; nulla isolatio inter canales singulos |
| Dimensiones | 30 × 81 × 52 mm (lat. × alt. × prof.) |
| Pondus Approximatum | 85 G |
Quaestiones Frequenter Rogatae
Potestne 6ES7138-4FB04-0AB0 in statione salutis ET 200S, quae in PROFINET fundatur, uti?
Hoc modulum configurationem PROFINET cum interfacie IM 151-3 HF sustinet.
Possuntne omnes quattuor exsitus 6ES7138-4FB04-0AB0 continuo 2 A simul ferre?
Totus currus intra limitem moduli (6 A) et intra limitem temperaturae montis manere debet.
Quis totus currus exsitus permittitur pro 6ES7138-4FB04-0AB0, si horizontali modo ad 55 °C montatur?
Limitis totius currus pro montibus horizontalibus est 5 A usque ad 55 °C.
Possumne duos canales 6ES7138-4FB04-0AB0 parallelos facere, ut capacitas currus augeatur?
Coniunctio exsitus parallela non permittitur, neque ad augendum currum neque ad controllem oneris redundatem.
Num 6ES7138-4FB04-0AB0 diagnoscet filum oneris apertum?
Hoc modulum diagnosticam rupturae fili praebet.
Can 6ES7138-4FB04-0AB0 be used to drive a digital input directly?
The outputs are not specified for controlling a digital input.
What is the smallest permitted on-state load current for 6ES7138-4FB04-0AB0?
The minimum permissible signal-one load current is 20 mA.