Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7138 4de02 0ab0 simatic et 200s 1count 5 v counter module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7138-4DE02-0AB0 SIMATIC ET 200S 1Count 5 V Counter Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200S

6ES7138-4DE02-0AB0 SIMATIC ET 200S 1Count 5 V Counter Module

A single-channel 32-bit counter for RS422 incremental encoders, with frequency measurement up to 500 kHz, one control input and two digital outputs.

At a Glance

Brand Siemens
Model 6ES7138-4DE02-0AB0
Product Type Counter and measuring electronics module
Core Function Evaluating incremental encoder pulses
Application ET 200S counting and measurement stations

Evaluate incremental position signals

One 32-bit counting channel accepts differential A/notA, B/notB and N/notN encoder signals.

Measure signal dynamics

Frequency, cycle duration and speed can be measured over their respective configured ranges.

Coordinate external events

The digital input supports gate control, synchronization and latch functions, while two outputs provide local switching signals.

Product Overview

6ES7138-4DE02-0AB0 processes a symmetrical incremental-encoder signal in an ET 200S station. The module supports counting and measurement with clock synchronization and evaluates quadrature A/B signals together with the zero mark.

A separate digital control input handles gating, synchronization or latching, and two digital outputs provide local switching. Measurement functions cover frequency, cycle duration and speed, with dedicated direction and synchronization indicators.

Ordering focus: Match the RS422 incremental encoder, measurement range, control-input function and encoder-cable length to the station configuration.
Key Functions

Evaluate incremental position signals

One 32-bit counting channel accepts differential A/notA, B/notB and N/notN encoder signals.

Measure signal dynamics

Frequency, cycle duration and speed can be measured over their respective configured ranges.

Coordinate external events

The digital input supports gate control, synchronization and latch functions, while two outputs provide local switching signals.

Official Specifications
Counting resource 1 counter channel, 32 bits
Module supply range 24 V DC nominal; 20.4–28.8 V DC
Maximum supply currents 45 mA from L+ without load; 10 mA from the 3.3 V backplane
Typical power loss 2 W
Encoder signal format RS422 differential A/notA, B/notB and N/notN; A/B shifted by 90°
Minimum differential input voltage 1 V
Encoder input termination 330 Ω
Maximum encoder input frequency 650 kHz
Shielded encoder cable length 50 m; limited to 30 m above 500 kHz
Frequency measurement range 0.1 Hz–500 kHz
Cycle-duration measurement range 10 µs–120 s
Speed measurement range 1–25,000 rpm
Control input 1 digital input, IEC 61131 type 2
Control-input thresholds Signal 0: −30 to +5 V; signal 1: +11 to +30 V
Control-input timing Maximum 2.5 µs rising-edge delay; shielded cable up to 50 m
Digital outputs 2 outputs, rated 2 A each; electronically short-circuit protected
Maximum output switching rates 100 Hz resistive; 2 Hz inductive; 10 Hz lamp load
Maximum output-cable lengths 1,000 m shielded; 600 m unshielded
Counter isolation Isolated from the backplane bus; not isolated from load voltage L+
Dimensions and approximate mass 30 × 81 × 52 mm; 65 g
Frequently Asked Questions

Which encoder signal type should I use with 6ES7138-4DE02-0AB0?

Use a symmetrical RS422 incremental encoder with differential A, B and zero-mark signals.

Can I run a 50 m encoder cable above 500 kHz with 6ES7138-4DE02-0AB0?

Above 500 kHz the shielded encoder cable is limited to 30 m.

Does the 650 kHz input limit of 6ES7138-4DE02-0AB0 also define its frequency-measurement range?

The encoder input accepts up to 650 kHz, while frequency measurement is limited to 500 kHz.

Can an external event latch the count on 6ES7138-4DE02-0AB0?

The digital control input can be assigned a latch function.

Which pulse-period range can 6ES7138-4DE02-0AB0 measure?

Cycle-duration measurement covers 10 µs to 120 seconds.

Can 6ES7138-4DE02-0AB0 measure rotational speed?

The speed-measurement function covers 1 to 25,000 rpm.

How can I distinguish count direction locally on 6ES7138-4DE02-0AB0?

Separate green forward-counting and backward-counting indicators show the count direction.

Compatibility & Ordering Notes
Before ordering 6ES7138-4DE02-0AB0: Match the RS422 incremental encoder, measurement range, control-input function and encoder-cable length to the station configuration.

Before installation

  • Use the RS422 encoder interface rather than connecting a conventional 24 V pulse signal to the differential encoder pins.
  • Maintain the shorter 30 m encoder-cable limit when the input frequency exceeds 500 kHz.
  • Assign the control input to the required gate, synchronization or latch operation.
  • Match output load type to the permitted switching frequency and retain the 30 mm station width.
Hot Selling Models
T0-2-15512/I1 207093
2U/a10ba/aa-1.41-110/11k
RLS-M-50
1005229/1643
0110096 0110096000000000 7447058
BAU3X2
6ES7131-6BH01-0BA0
3VU1300-1ML00 99.80.0.024.98
3RV2411-1FA10
PSU8200 6EP3436-8SB00-0AY0
SS5Y3-41-04-M5F-Q
VS-PNRJ45-PNRJ45-93B-1.5
ESS20-001-DC24V-10A
5SY6214-7
PSK1 1005229/9917

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop