Siemens 6ES7138-4DC00-0AB0 SIMATIC ET 200S 1STEP 5V/204kHz Stepper Positioning Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Select a stepper power section with the required differential pulse/direction input.
- Separate the power-section output-cable requirements from the longer digital-input cable limits.
- Wire and test the REF cam and DI stop or pulse-disable functions before running the axis.
- Check the ET 200S station terminal arrangement and 24 V load supply.
6ES7138-4DC00-0AB0 SIMATIC ET 200S 1STEP 5V/204kHz Stepper Positioning Module
Single-channel 1STEP module with a 5 V differential stepper interface, pulse output up to 204 kHz and two 24 V digital inputs.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7138-4DC00-0AB0 |
| Product Type | Stepper-motor positioning module |
| Core Function | Generating pulse and direction commands for a stepper power section |
| Application | Single-axis positioning in ET 200S stations |
Stepper command generation
One positioning channel supplies differential PULSE/notPULSE and DIR/notDIR signals to the power section.
Reference and stop inputs
REF accepts the reference cam; DI can serve as pulse disable or external stop.
Commissioning indication
RDY, POS, SF and digital-input status LEDs indicate module and positioning state.
Product Overview
6ES7138-4DC00-0AB0 generates positioning commands for a stepper-motor power section through differential pulse and direction signals.
The reference input supports a reference cam, while the additional digital input can inhibit pulses or provide an external stop, making the field wiring part of the positioning arrangement.
Key Functions
Stepper command generation
One positioning channel supplies differential PULSE/notPULSE and DIR/notDIR signals to the power section.
Reference and stop inputs
REF accepts the reference cam; DI can serve as pulse disable or external stop.
Commissioning indication
RDY, POS, SF and digital-input status LEDs indicate module and positioning state.
Official Specifications
| Positioning channels | 1 |
|---|---|
| Stepper output interface | 5 V differential pulse and direction signals to RS-422 |
| Maximum pulse-output frequency | 204 kHz |
| Maximum power-section cable | 100 m; twisted and shielded in pairs |
| Rated load supply | 24 V DC with reverse-polarity protection |
| Typical no-load L+ current | 40 mA |
| Maximum backplane current | 10 mA from 3.3 V DC |
| Typical power loss | 1.5 W |
| Digital inputs | 2: REF for reference cam; DI for pulse disable or external stop |
| Digital-input repeat frequency | Maximum 1 kHz |
| Digital-input characteristic | IEC 61131 Type 2 |
| Input signal thresholds | Signal 0: −30 to +5 V; signal 1: +11 to +30 V |
| Digital-input current | Typical 9 mA at signal 1; maximum 2 mA quiescent current |
| Maximum input delay | 300 µs for either transition |
| Maximum digital-input cable | 1,000 m shielded; 600 m unshielded |
| Two-wire sensors | Connectable to the digital inputs |
| Status LEDs | RDY, green POS, red SF and green input indication |
| Dimensions (W × H × D) | 15 × 81 × 52 mm |
| Approximate weight | 40 g |
Frequently Asked Questions
Can a stepper motor winding be connected directly to 6ES7138-4DC00-0AB0?
The module supplies pulse and direction commands to a separate stepper power section rather than driving the motor winding.
What signal format does the power section need for 6ES7138-4DC00-0AB0?
The power section must accept the differential RS-422 PULSE/notPULSE and DIR/notDIR signals.
Where is a reference cam connected on 6ES7138-4DC00-0AB0?
Connect the reference-cam signal to the REF digital input.
Can an external stop signal be connected to 6ES7138-4DC00-0AB0?
The DI input can be used for external stop or pulse disable.
Does the long digital-input cable limit also apply to the power-section cable on 6ES7138-4DC00-0AB0?
The power-section cable is limited to 100 m and must be twisted and shielded in pairs.
Can 6ES7138-4DC00-0AB0 accept a two-wire sensor on its digital inputs?
Two-wire sensors are supported when their quiescent current stays within the specified 2 mA limit.
Which indication identifies positioning operation on 6ES7138-4DC00-0AB0?
The green POS LED indicates positioning mode.