Siemens 6ES7138-4DC00-0AB0 SIMATIC ET 200S 1STEP 5V/204kHz Stepper Positioning Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Select a stepper power section with the required differential pulse/direction input.
- Separate the power-section output-cable requirements from the longer digital-input cable limits.
- Wire and test the REF cam and DI stop or pulse-disable functions before running the axis.
- Controlla la disposizione dei terminali della stazione ET 200S e l’alimentazione della carica a 24 V.
6ES7138-4DC00-0AB0 SIMATIC ET 200S 1STEP 5V/204kHz Stepper Positioning Module
Single-channel 1STEP module with a 5 V differential stepper interface, pulse output up to 204 kHz and two 24 V digital inputs.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7138-4DC00-0AB0 |
| Typus Producti | Stepper-motor positioning module |
| Functio principalis | Generating pulse and direction commands for a stepper power section |
| Applicatio | Single-axis positioning in ET 200S stations |
Generation of stepper command
One positioning channel supplies differential PULSE/notPULSE and DIR/notDIR signals to the power section.
Reference and stop inputs
REF accepts the reference cam; DI can serve as pulse disable or external stop.
Indicatio commissionis
RDY, POS, SF and digital-input status LEDs indicate module and positioning state.
Product Overview
6ES7138-4DC00-0AB0 Generates positioning commands for a stepper-motor power section through differential pulse and direction signals.
The reference input supports a reference cam, while the additional digital input can inhibit pulses or provide an external stop, making the field wiring part of the positioning arrangement.
Key Functions
Generation of stepper command
One positioning channel supplies differential PULSE/notPULSE and DIR/notDIR signals to the power section.
Reference and stop inputs
REF accepts the reference cam; DI can serve as pulse disable or external stop.
Indicatio commissionis
RDY, POS, SF and digital-input status LEDs indicate module and positioning state.
Official Specifications
| Positioning Channels | 1 |
|---|---|
| Stepper output interface | 5 V differential pulse and direction signals to RS-422 |
| Frequencia Maxima Impulsuum Emissionis | 204 kHz |
| Maximum power-section cable | 100 m; twisted and shielded in pairs |
| Alimentatio oneris nominalis | 24 V DC cum protectione contra inversionem polaritatis |
| Typical no-load L+ current | 40 mA |
| Currentis Maxima Planae Posterioris | 10 mA ex 3.3 V DC |
| Perditio potentiæ typica | 1.5 W |
| Ingressus Digitales | 2: REF for reference cam; DI for pulse disable or external stop |
| Digital-input repeat frequency | Maximum 1 kHz |
| Characteristica intratae digitalis | IEC 61131 Typus 2 |
| Limina Signali Inputii | Signum 0: −30 ad +5 V; signum 1: +11 ad +30 V |
| Currentia Input Digitalis | Typical 9 mA at signal 1; maximum 2 mA quiescent current |
| Délai d’entrée maximal | 300 µs for either transition |
| Maximum digital-input cable | 1 000 m scutum; 600 m non scutum |
| Sensoribus duobus filis | Connectable to the digital inputs |
| Diodi Luminis Status | RDY, viridis POS, ruber SF et viridis input indicatio |
| Dimensiones (L × H × D) | 15 × 81 × 52 mm |
| Pondus Approximatum | 40 g |
Quaestiones Frequenter Rogatae
Num posset motoris passus bobina directe ad 6ES7138-4DC00-0AB0 coniungi?
Modulus impulsum et directionem ad separatam potentiam passus partem praebet, non autem motorem bobinam movet.
Qualem signi formam potentiae sectio pro 6ES7138-4DC00-0AB0 requirit?
Potentiae sectio differentialem RS-422 signum PULSE/nonPULSE et DIR/nonDIR accipere debet.
Ubi camma referentiae ad 6ES7138-4DC00-0AB0 connectitur?
Signum cammae referentiae ad digitalem REF intritum connecte.
Num signum externum stop ad 6ES7138-4DC00-0AB0 coniungi potest?
Intritus DI pro externo stop vel impulsum inhibendo uti potest.
Does the long digital-input cable limit also apply to the power-section cable on 6ES7138-4DC00-0AB0?
The power-section cable is limited to 100 m and must be twisted and shielded in pairs.
Can 6ES7138-4DC00-0AB0 accept a two-wire sensor on its digital inputs?
Two-wire sensors are supported when their quiescent current stays within the specified 2 mA limit.
Which indication identifies positioning operation on 6ES7138-4DC00-0AB0?
The green POS LED indicates positioning mode.