Siemens 6ES7136-6DB00-0CA0 SIMATIC ET 200SP F-DQ 4x24VDC/2A PM HF Safety Output Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use an A0 BaseUnit and retain the F-type electronic coding arrangement.
- Account for the 6 A module total as well as individual 2 A channel limits.
- Apply the horizontal or vertical temperature limit and the applicable derating.
- Validate the complete fail-safe application before commissioning the actuator circuits.
6ES7136-6DB00-0CA0 SIMATIC ET 200SP F-DQ 4x24VDC/2A PM HF Safety Output Module
A four-channel 24 V DC safety output module rated at 2 A per channel, with automatic F coding and capability up to PL e / SIL 3.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7136-6DB00-0CA0 |
| Product Type | Fail-safe digital output electronics module |
| Core Function | Switching safety-related DC actuators |
| Application | ET 200SP fail-safe I/O stations |
Switch fail-safe actuator circuits
Four parameterizable transistor outputs each carry up to 2 A, subject to the module total and thermal derating.
Detect output-circuit faults
Open-circuit, overload and short-circuit detection support channel fault handling.
Integrate into a safety station
The module supports engineering from TIA Portal V12 or STEP 7 V5.5 SP3 and uses automatic F-type electronic coding.
Product Overview
6ES7136-6DB00-0CA0 provides four transistor outputs for fail-safe ET 200SP applications. The F-DQ PM HF module uses an A0 BaseUnit and an F-type electronic coding element.
Diagnostics include open-circuit, overload and short-circuit detection, complemented by channel and module indicators. The achievable safety capability extends to PL e and SIL 3 within the applicable safety configuration.
Key Functions
Switch fail-safe actuator circuits
Four parameterizable transistor outputs each carry up to 2 A, subject to the module total and thermal derating.
Detect output-circuit faults
Open-circuit, overload and short-circuit detection support channel fault handling.
Integrate into a safety station
The module supports engineering from TIA Portal V12 or STEP 7 V5.5 SP3 and uses automatic F-type electronic coding.
Official Specifications
| Output channels and switching technology | 4 transistor outputs |
|---|---|
| Supply rating and operating range | 24 V DC; 19.2–28.8 V DC |
| No-load current consumption | 75 mA rated |
| Backplane consumption | Maximum 21 mA; 70 mW |
| Typical module loss | 4 W |
| Process address allocation | 5 input bytes and 5 output bytes |
| Rated current per output | 2 A |
| Maximum total module current | 6 A, subject to derating |
| Maximum off-state residual current | 0.5 mA |
| Load resistance range | 12–2,000 Ω |
| Maximum lamp load | 10 W |
| Typical open-circuit threshold | 8 mA |
| Typical overload threshold | 2.9 A |
| Typical short-circuit response threshold | Greater than 3.3 A |
| Maximum symmetric switching rates | 30 Hz resistive; 0.1 Hz inductive DC-13; 10 Hz lamp load |
| Maximum output cable lengths | 1,000 m shielded; 500 m unshielded |
| Isolation test | 707 V DC type test |
| Maximum achievable safety classes | PL e to ISO 13849-1; SIL 3 to IEC 61508 |
| Operating temperature by orientation | 0–60 °C horizontal; 0–50 °C vertical |
| Module dimensions and approximate weight | 15 × 73 × 58 mm; 57 g |
Frequently Asked Questions
Which BaseUnit type is required for 6ES7136-6DB00-0CA0?
The module requires a BaseUnit of type A0.
Can all four channels of 6ES7136-6DB00-0CA0 continuously supply 2 A together?
The module total is limited to 6 A and remains subject to thermal derating.
What project address space should I allow for 6ES7136-6DB00-0CA0?
Reserve five input bytes and five output bytes.
Which engineering versions can configure 6ES7136-6DB00-0CA0?
Configuration is available from TIA Portal V12 or STEP 7 V5.5 SP3.
Will 6ES7136-6DB00-0CA0 detect a disconnected actuator circuit?
The module provides open-circuit detection with a typical 8 mA threshold.
Can I use 6ES7136-6DB00-0CA0 in a SIL 3 safety design?
The module can achieve SIL 3 within an appropriately configured and validated safety application.
Which coding element prevents incorrect replacement of 6ES7136-6DB00-0CA0?
The module uses an automatic F-type electronic coding element.