Overview
Siemens · SIMATIC ET 200iSP
6ES7134-7TD00-0AB0 4 AI HART 2-Wire Analog Input Module
Siemens 6ES7134-7TD00-0AB0 is the SIMATIC ET 200iSP 4 AI HART analog input module for four 4 to 20 mA two-wire transmitters with HART 6.0 and intrinsically safe field circuits.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7134-7TD00-0AB0 |
| Product Type | Four-channel intrinsically safe HART analog input module |
| Core Function | Acquires 4 to 20 mA signals and HART data from two-wire transmitters |
| Application or Compatible Series | SIMATIC ET 200iSP process I/O stations in hazardous areas |
Ex Verification
Validate the complete intrinsic-safety loop, zone classification and permitted field-device data.
HART Setup
Copy channel addresses, HART variables, polling configuration and transmitter parameters.
Current Loop Check
Confirm every two-wire transmitter, polarity, shield and 4 to 20 mA measurement range.
Product Overview
Siemens 6ES7134-7TD00-0AB0 is the SIMATIC ET 200iSP 4 AI HART analog input module for four 4 to 20 mA two-wire transmitters with HART 6.0 and intrinsically safe field circuits.
Four analog channels acquire current signals and digital HART process information. Each channel supplies a protected current loop for a compatible two-wire transmitter. The module is designed for the specified intrinsically safe ET 200iSP field circuits.
Key Functions
Four HART Inputs
Four analog channels acquire current signals and digital HART process information.
Two-Wire Transmitter Supply
Each channel supplies a protected current loop for a compatible two-wire transmitter.
Hazardous-Area Capability
The module is designed for the specified intrinsically safe ET 200iSP field circuits.
Official Specifications
| Product Designation | 4 AI I 2WIRE HART |
|---|---|
| Hardware Functional Status | FS17 |
| Firmware Version | V3.0.4 |
| Number of Analog Inputs | 4 |
| Supported Input Type | Current |
| Nominal Measuring Range | 4 to 20 mA |
| Supported HART Version | 6.0 |
| Transmitter Connection | 2-wire |
| Supply Voltage Type | DC |
| Permitted Supply Range | 20.4 to 28.8 V DC |
| Typical Current Consumption | 280 mA |
| Maximum Power-Bus Current | 320 mA |
| Typical Power Loss | 2.7 W |
| Maximum Transmitter Supply Current | 23 mA per channel |
| Transmitter Supply Protection | Short-circuit proof |
| Maximum Input Destruction Current | 90 mA |
| Maximum All-Channel Cycle Time | 120 ms |
| Mounting | Front and rail mounting |
| Separate Fieldbus Transceiver | Required |
| Isochronous Mode | Not supported |
Frequently Asked Questions
Which transmitters can I connect to 6ES7134-7TD00-0AB0?
Use compatible two-wire 4 to 20 milliampere transmitters that meet the approved intrinsic-safety loop data.
How many HART channels are available on 6ES7134-7TD00-0AB0?
Four analog input channels support HART communication.
What supply range is required by 6ES7134-7TD00-0AB0?
Provide a DC supply within 20.4 to 28.8 volts at the module power bus.
What must I validate for hazardous-area use of 6ES7134-7TD00-0AB0?
Check the zone, protection method, loop voltage, current, power, capacitance, inductance and associated apparatus.
Why might one channel on 6ES7134-7TD00-0AB0 fail to power a transmitter?
Inspect the loop polarity, field wiring, short circuit, transmitter load and channel configuration.
What should I copy before exchanging 6ES7134-7TD00-0AB0?
Copy each channel range, HART address, process variable, diagnostic setting and transmitter assignment.
How should I commission 6ES7134-7TD00-0AB0 after wiring?
Verify loop current, engineering value, HART communication, alarms and intrinsic-safety records channel by channel.
Compatibility & Ordering Notes
Compatibility Checklist
- Use the exact ET 200iSP 4 AI HART two-wire module entry in the station configuration.
- Validate each field loop against the approved intrinsic-safety parameters before connection.
- Restore HART addresses, channel ranges, diagnostic behavior, shields and transmitter assignments.