Overview
SIMATIC ET 200SP

6ES7134-6HD00-0BA1 ET 200SP AI 4xU/I 2-wire ST Module

Four differential analog inputs for voltage or two-wire current measurement, with up to 16-bit resolution and module diagnostics.

At a Glance

Brand Siemens
Model 6ES7134-6HD00-0BA1
Product Type Standard analog input module
Core Function Acquisition of voltage and two-wire current signals
Application ET 200SP process instrumentation

Voltage and two-wire current acquisition

Use 0–10 V, 1–5 V, ±10 V, ±5 V, 0–20 mA or 4–20 mA measuring ranges.

Configurable signal processing

Select 16.6, 50 or 60 Hz interference suppression and one of four smoothing levels.

Process diagnostics

Monitor supply voltage, wire break, short circuit and range overflow or underflow through diagnostic alarms.

Product Overview

6ES7134-6HD00-0BA1 integrates four differential analog inputs in an ET 200SP station for voltage signals and two-wire current transmitters.

BU types A0 and A1 provide the matching connection base, and CC03 identifies the module-specific terminal color code; diagnostic functions include wire break at 4–20 mA and configured short-circuit detection.

Ordering focus: Match BU type A0 or A1, CC03 terminal identification and the two-wire current-transmitter arrangement before selecting the measuring ranges.
Key Functions

Voltage and two-wire current acquisition

Use 0–10 V, 1–5 V, ±10 V, ±5 V, 0–20 mA or 4–20 mA measuring ranges.

Configurable signal processing

Select 16.6, 50 or 60 Hz interference suppression and one of four smoothing levels.

Process diagnostics

Monitor supply voltage, wire break, short circuit and range overflow or underflow through diagnostic alarms.

Official Specifications
Supply Voltage 24 V DC; permissible range 19.2–28.8 V
Maximum Current Consumption 37 mA without sensor supply
Sensor Supply Output 20 mA maximum per channel; up to 50 mA for less than 10 s
Typical Power Loss 0.85 W without sensor supply
Input Address Space 8 bytes plus 1 byte of quality information
Voltage Measuring Ranges 0–10 V, 1–5 V, ±10 V and ±5 V
Current Measuring Ranges 0–20 mA and 4–20 mA
Maximum Resolution 16 bits including sign
Voltage Input Resistance 120 kΩ
Current Input Resistance 100 Ω plus approximately 0.7 V diode forward drop
Maximum Two-Wire Transmitter Burden 650 Ω
Per-Channel Conversion Time 180, 60 or 50 ms
Interference Suppression Frequencies 16.6, 50 or 60 Hz
Digital Smoothing None, 4, 8 or 16 times
Voltage and Current Error Limits ±0.3% at 25 °C; ±0.5% across the operating temperature range
Maximum Shielded Cable 1,000 m for current; 200 m for voltage
Isolation Test Voltage 707 V DC, type test
Dimensions and Approximate Weight 15 × 73 × 58 mm; 31 g
Frequently Asked Questions

Which BaseUnits fit 6ES7134-6HD00-0BA1?

The module is suitable for BU types A0 and A1 and uses the CC03 terminal color code.

Can I connect four-wire current transmitters to 6ES7134-6HD00-0BA1?

The current inputs are intended for two-wire transmitters, while four-wire current-transmitter connection is not supported.

How much quality information should I allocate for 6ES7134-6HD00-0BA1?

The module uses up to eight input bytes plus one byte for quality information.

Will 6ES7134-6HD00-0BA1 detect an open 4–20 mA loop?

Wire-break diagnostics are available in the 4–20 mA range.

Can I reparameterize 6ES7134-6HD00-0BA1 while the station is running?

Reparameterization is possible in RUN, while calibration in RUN is not supported.

How long can voltage signal cables run to 6ES7134-6HD00-0BA1?

Shielded cables for voltage measurement can be up to 200 m long.

Which STEP 7 versions can configure 6ES7134-6HD00-0BA1?

Configuration is available from TIA Portal V11 SP2 and STEP 7 V5.5 SP3, with TIA integration from V13.

Compatibility & Ordering Notes
Before ordering 6ES7134-6HD00-0BA1: Match BU type A0 or A1, CC03 terminal identification and the two-wire current-transmitter arrangement before selecting the measuring ranges.

Before installation

  • Use BU type A0 or A1 and apply the CC03 terminal identification.
  • Connect current sensors as two-wire transmitters within the 650 Ω burden limit.
  • Allocate the extra quality-information byte when using QI data.
  • Select filtering and interference suppression to match the required process response.
Hot Selling Models
ADVU-16-10-PA
PSK1 1005229/9630
22-54/35/41/47/74a
3RV2011-0JA15
VN-14-L-T4-PQ3-VQ3-RO2-B
IVH-F61
1.DM.12080
3RT1935-5AK61
SY5340R-5DZ-Q
XBC-D29202C12
WDU2.5 1020000000
010-0200
M/90050/M/25
ABB S402M B6 + SK400 10-R SA + HK400 11-R
EZAELN3002B153

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.