Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7132 7rd01 0ab0 4 do 23 1 v dc 20 ma h shutdown module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC ET 200iSP 6ES7132-7RD01-0AB0 4 DO 23.1 V DC/20 mA H-Shutdown Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMATIC ET 200iSP

6ES7132-7RD01-0AB0 4 DO 23.1 V DC/20 mA H-Shutdown Module

The 6ES7132-7RD01-0AB0 electronic module provides four transistor outputs at up to 23.1 V DC and 20 mA for ET 200iSP hazardous-area applications with H-shutdown.

At a Glance

Brand Siemens
Model 6ES7132-7RD01-0AB0
Product Type Intrinsically safe four-channel digital output module
Core Function Switches four low-current field outputs and supports H-type shutdown in hazardous-area stations
Application or Compatible Series SIMATIC ET 200iSP installations with intrinsically safe output circuits

Exact Identification

Match 6ES7132-7RD01-0AB0 character by character before replacement.

Interface Check

Confirm the installed supply, terminals, network and field wiring.

Project Backup

Preserve the validated configuration and application data before exchange.

Product Overview

The 6ES7132-7RD01-0AB0 electronic module provides four transistor outputs at up to 23.1 V DC and 20 mA for ET 200iSP hazardous-area applications with H-shutdown.

The module drives four field outputs within the documented Ex ib limits. A separate intrinsically safe input provides the documented H-type output shutdown function. The station can monitor output conditions and module faults through the configured process system.

Ordering focus: verify the complete article number, hazardous-area approval, 23.1 V/20 mA load limits, H-shutdown circuit and ET 200iSP project.

Key Functions

Four Intrinsically Safe Outputs

The module drives four field outputs within the documented Ex ib limits.

H-Shutdown Input

A separate intrinsically safe input provides the documented H-type output shutdown function.

ET 200iSP Diagnostics

The station can monitor output conditions and module faults through the configured process system.

Official Specifications

Digital Output Channels 4
Additional Shutdown Input 1 intrinsically safe H-shutdown input
Output Technology Transistor
Output Voltage Type DC
Permissible Output Voltage 0 to 23.1 V DC
Rated Output Current per Channel 20 mA
Maximum Address Space 2 bytes
Output Delay with Resistive Load 2 ms maximum for 0→1 and 1→0
Output Characteristic Resistance 275 Ω
Characteristic Point Voltage 17.6 V DC
Characteristic Point Current 20 mA
Hardware Functional Status 7
Firmware Version V3.0.0
Mounting Method Front mounting on the ET 200iSP carrier
Fieldbus Connection Via separate ET 200iSP coupler
Explosion Protection Ex ib circuits for gas, dust and mining applications

Frequently Asked Questions

Which loads are suitable for 6ES7132-7RD01-0AB0?

Use intrinsically safe field loads that remain within the 23.1 V DC and 20 mA channel limits.

How is the H-shutdown function wired on 6ES7132-7RD01-0AB0?

Connect the dedicated intrinsically safe shutdown input exactly as defined in the ET 200iSP safety design.

How much address space should be reserved for 6ES7132-7RD01-0AB0?

Allocate two bytes in the station configuration.

Can 6ES7132-7RD01-0AB0 be used outside an ET 200iSP station?

No, it is engineered for the ET 200iSP platform and its approved hazardous-area architecture.

What must be checked before replacing 6ES7132-7RD01-0AB0?

Confirm the output circuit classification, carrier position, H-shutdown wiring and station parameters.

What switching delay applies to 6ES7132-7RD01-0AB0?

Allow up to 2 ms for either transition with a resistive load.

What commissioning test is required for 6ES7132-7RD01-0AB0?

Test every output, the shutdown path and the configured diagnostics under the approved safety procedure.

Compatibility & Ordering Notes

Before ordering 6ES7132-7RD01-0AB0: verify the complete article number, hazardous-area approval, 23.1 V/20 mA load limits, H-shutdown circuit and ET 200iSP project.

Compatibility Checklist

  • Use the module only with approved ET 200iSP carriers and couplers.
  • Keep every field circuit within the documented intrinsic-safety parameters.
  • Validate the shutdown input and all four outputs before returning the process to service.
Hot Selling Models
ABB S202-C2 2CDS252001R0024
RK97/4S
5TE5801
3SB3501-0AA61
4414M
E6A3153
SV2100-5FUD
3RT2015-1AP04-3MA0
BES0086 BES M18MI-PSC50B-S04G
3SB3202-4AD11-0CC0
NM02RBA-M
6ES5752-0AA22
DL1BL024 033285 BA15d
Allen-Bradley 700-HK32Z24 700-HN222
4NA13 0.8/3/-kV 89/110

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.