Siemens SIMATIC ET 200iSP 6ES7132-7RD01-0AB0 4 DO 23.1 V DC/20 mA Modulus H-Shutdown
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use the module only with approved ET 200iSP carriers and couplers.
- Keep every field circuit within the documented intrinsic-safety parameters.
- Validate the shutdown input and all four outputs before returning the process to service.
SIEMENS · SIMATIC ET 200iSP
6ES7132-7RD01-0AB0 4 DO 23.1 V DC/20 mA H-Shutdown Module
The 6ES7132-7RD01-0AB0 electronic module provides four transistor outputs at up to 23.1 V DC and 20 mA for ET 200iSP hazardous-area applications with H-shutdown.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7132-7RD01-0AB0 |
| Typus Producti | Intrinsically safe four-channel digital output module |
| Functio principalis | Switches four low-current field outputs and supports H-type shutdown in hazardous-area stations |
| Applicatio vel series compatibiles | SIMATIC ET 200iSP installations with intrinsically safe output circuits |
Identificatio exacta.
Match 6ES7132-7RD01-0AB0 character by character before replacement.
Interface Check
Confirm the installed supply, terminals, network, and field wiring.
REZERVARE PROIECT
Preserve the validated configuration and application data before exchange.
Product Overview
The 6ES7132-7RD01-0AB0 electronic module provides four transistor outputs at up to 23.1 V DC and 20 mA for ET 200iSP hazardous-area applications with H-shutdown.
The module drives four field outputs within the documented Ex ib limits. A separate intrinsically safe input provides the documented H-type output shutdown function. The station can monitor output conditions and module faults through the configured process system.
Key Functions
Four Intrinsically Safe Outputs
The module drives four field outputs within the documented Ex ib limits.
H-Shutdown Input
A separate intrinsically safe input provides the documented H-type output shutdown function.
ET 200iSP Diagnostics
The station can monitor output conditions and module faults through the configured process system.
Official Specifications
| Canalibus de output digitalis | 4 |
|---|---|
| Additional Shutdown Input | 1 intrinsically safe H-shutdown input |
| Output technology | Transistor |
| Typus Tensionis Egressus | DC |
| Permissible Output Voltage | 0 to 23.1 V DC |
| Rated Output Current per Channel | 20 mA |
| Maxima Spatium Adressarum | 2 octeta |
| Morae outputis cum onere resistivo | 2 ms maximum pro 0→1 et 1→0 |
| Resistentia characteristica output | 275 Ω |
| Tensio puncti characteristici | 17.6 V DC |
| Current puncti characteristici | 20 mA |
| Status Functionalis Hardware | 7 |
| Versio Firmamentalis | V3.0.0 |
| Modus montandi | Montatio anterior in portatore ET 200iSP |
| Conexus Fieldbus | Per coupler separatam ET 200iSP |
| Protectio contra Explosionem | Circuitus Ex ib pro applicationibus gas, pulvis et mining |
Quaestiones Frequenter Rogatae
Quae onera sunt idonea pro 6ES7132-7RD01-0AB0?
Ute intrinsece securas campos de onus quae intra limites canalium 23.1 V DC et 20 mA manent.
Quomodo functio H-shutdown in 6ES7132-7RD01-0AB0 conectitur?
Conecte intrinsece securum introitum pro extinctione specialiter ut definitum est in designo securitatis ET 200iSP.
Quantum spatii adressionis reservandum est pro 6ES7132-7RD01-0AB0?
Alloca duos bytes in configuratione stationis.
Potestne 6ES7132-7RD01-0AB0 extra stationem ET 200iSP uti?
Non, hoc instrumentum ad platformam ET 200iSP et suam architecturam approbatam pro areis periculosis fabricatum est.
Quid ante substitutionem 6ES7132-7RD01-0AB0 inspiciendum est?
Confirma classificationem circuitus exirentis, positionem portatoris, connexionem H-shutdown et parametres stationis.
Quod tempus morae commutationis ad 6ES7132-7RD01-0AB0 pertinet?
Allow up to 2 ms for either transition with a resistive load.
What commissioning test is required for 6ES7132-7RD01-0AB0?
Test every output, the shutdown path and the configured diagnostics under the approved safety procedure.