Siemens 6ES7131-6BH01-0BA0 ET 200SP DI 16x24VDC ST Digital Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200SP

6ES7131-6BH01-0BA0 ET 200SP DI 16x24VDC ST Digital Input Module

A 16-channel P-reading input module with adjustable filtering, supply diagnostics and wire-break monitoring.

At a Glance

Brand Siemens
Model 6ES7131-6BH01-0BA0
Product Type Digital input module
Core Function Acquiring discrete field signals
Application Distributed machine I/O

Filter field inputs

Input delay settings span 0.05 to 20 ms, with the specified additional hardware delay.

Locate wiring faults

Wire-break diagnostics can be enabled for the module, with 25–45 kΩ parallel resistors required for simple contacts.

Read channel quality

The input address area uses two bytes of process data and another two bytes for quality information.

Product Overview

6ES7131-6BH01-0BA0 collects 24 V DC field signals with an IEC 61131 Type 3 input characteristic.

Configurable input delays help match the response to field devices, while channel quality information and local status LEDs support commissioning.

Ordering focus: Use an A0 BaseUnit with CC00 coding and a suitable 24 V DC field supply.
Key Functions

Filter field inputs

Input delay settings span 0.05 to 20 ms, with the specified additional hardware delay.

Locate wiring faults

Wire-break diagnostics can be enabled for the module, with 25–45 kΩ parallel resistors required for simple contacts.

Read channel quality

The input address area uses two bytes of process data and another two bytes for quality information.

Official Specifications
Input Channels 16 P-reading inputs for PNP sensors
Supply Range 24 V DC nominal; 19.2–28.8 V DC
Maximum Current Consumption 90 mA
Typical Power Loss 1.7 W
Input Characteristic IEC 61131 Type 3
Signal Thresholds Signal 0: −30 to +5 V; signal 1: +11 to +30 V
Typical Signal 1 Current 2.5 mA
Selectable Input Delays 0.05, 0.1, 0.4, 0.8, 1.6, 3.2, 12.8 and 20 ms, plus 30–500 µs hardware delay
Process Input Allocation 2 bytes plus 2 bytes for quality information
Maximum Cable Length 1,000 m shielded; 600 m unshielded
Two-Wire Sensor Quiescent Current Maximum 1.5 mA
Diagnostic Indicators Green PWR and channel LEDs; green/red DIAG LED
Isolation Test Voltage 707 V DC between channels and backplane bus
Dimensions (W × H × D) 15 × 73 × 58 mm
Net Weight 28 g
Official source:Siemens product data sheet
Frequently Asked Questions

Which BaseUnit fits 6ES7131-6BH01-0BA0?

Use a BaseUnit of type A0 with the CC00 color code.

Can 6ES7131-6BH01-0BA0 accept signals from PNP proximity sensors?

The module uses P-reading inputs with an IEC 61131 Type 3 characteristic for 24 V DC signals.

How do I reduce contact bounce when using 6ES7131-6BH01-0BA0?

Select an input delay from 0.05 to 20 ms to suit the field signal and allow for the additional hardware delay.

Why does a dry contact need a resistor for wire-break monitoring on 6ES7131-6BH01-0BA0?

A 25–45 kΩ parallel resistor provides the current path needed for wire-break diagnostics with a simple contact.

How much input address space should I reserve for 6ES7131-6BH01-0BA0 with quality information?

Reserve two bytes for the channel states and two additional bytes for quality information.

Can I wire two-wire sensors to 6ES7131-6BH01-0BA0?

Two-wire sensors are supported when their quiescent current does not exceed 1.5 mA.

Can 6ES7131-6BH01-0BA0 serve as a high-speed counter?

This Standard input module provides digital input operation without a counter operating mode.

Compatibility & Ordering Notes
Before ordering 6ES7131-6BH01-0BA0: Use an A0 BaseUnit with CC00 coding and a suitable 24 V DC field supply.

Before installation

  • Use TIA Portal V14 or later, or STEP 7 V5.5 SP3 or later, for integrated configuration.
  • Install on a type A0 BaseUnit and match the CC00 module coding.
  • Provide 19.2–28.8 V DC and plan the input and quality-information address bytes.
  • Keep field cable lengths within 1,000 m shielded or 600 m unshielded.
Hot Selling Models
KDC12K08
MFC30-10-8-A
PF1000 A 24V IP43
KG80T203/01E
H12WD4890
NF0120-503
DEHN 919347
DEHN 919344
MD 110 919547 032658
RT1045-1AP00
IN5370
NRN8-12GM45-E2-C-V1
IN5269 IN-2002-FRKG/AS-610-TRF
BOS01MW Q08M-PO-LR20-00.2-S49
3241.100

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.