Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7131 6bf01 0ba0 et 200sp di 8x24vdc st input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7131-6BF01-0BA0 ET 200SP DI 8x24VDC ST Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC ET 200SP

6ES7131-6BF01-0BA0 ET 200SP DI 8x24VDC ST Input Module

Eight type-3 inputs with individually selectable filtering, a protected sensor supply and module-level wire-break and supply diagnostics.

At a Glance

Brand Siemens
Model 6ES7131-6BF01-0BA0
Product Type Standard digital input module
Core Function Acquisition of PNP field signals
Application ET 200SP distributed input stations

Adjustable input filtering

Select input delays from 0.05 to 20 ms for the individual channels.

Sensor supply budget

The eight sensor-supply outputs share a maximum module current of 700 mA.

Value status

The input address occupies one byte, with one additional byte for quality information.

Product Overview

6ES7131-6BF01-0BA0 acquires eight field signals through P-reading inputs with an IEC 61131 type-3 characteristic. Channel filtering can be selected individually, while module diagnostics monitor the supply, sensor-supply short circuits and wire breaks.

The 15 mm-wide module uses an A0 BaseUnit and the CC01 color assignment. A common sensor-supply current limit applies across the module, so the individual terminal ratings must not be added together when budgeting connected sensors.

Ordering focus: Match the A0 BaseUnit, sensor wiring arrangement, input filtering and shared sensor-supply current before installing the module.
Key Functions

Filter field-contact transitions

Each channel permits a filter setting between 0.05 and 20 ms, with an additional line-dependent delay of 30–500 µs.

Monitor the input installation

Module diagnostics cover wire break, short circuits and supply-voltage monitoring, supported by PWR, channel-state and DIAG indicators.

Integrate input quality

The module provides one byte of input data and an additional byte for quality information.

Official Specifications
Digital inputs 8 P-reading inputs; IEC 61131 type 3
DC supply 24 V rated; permissible range 19.2–28.8 V
Input logic thresholds Signal 0: −30 to +5 V; signal 1: +11 to +30 V
Typical signal-1 input current 2.5 mA
Selectable input delays 0.05, 0.1, 0.4, 0.8, 1.6, 3.2, 12.8 or 20 ms, plus 30–500 µs line-dependent delay
Maximum module current consumption 50 mA when all channels use the sensor supply
Sensor-supply outputs 8 outputs; minimum output voltage 19.2 V
Sensor-supply current limit 700 mA maximum per module and per channel
Sensor-supply protection Short-circuit protection at module level
Maximum two-wire sensor quiescent current 1.5 mA
Maximum field-cable length 1,000 m shielded; 600 m unshielded
Input address allocation 1 input byte plus 1 byte for quality information
Local indicators Green PWR and channel LEDs; green/red DIAG LED
Electrical isolation No channel-to-channel isolation; isolation between channels and backplane
Insulation test voltage 707 V DC, type test
Typical power loss 1 W at 24 V with all eight inputs supplied via the sensor supply
Operating temperature Horizontal: −30 to +60 °C; vertical: −30 to +50 °C; operation below 0 °C from FS02
Dimensions and approximate weight 15 × 73 × 58 mm (W × H × D); 28 g
Frequently Asked Questions

Which BaseUnit should I pair with 6ES7131-6BF01-0BA0?

Use an A0 BaseUnit with the CC01 color assignment and select the terminal arrangement for the sensor wiring.

Can I feed 700 mA from every sensor terminal on 6ES7131-6BF01-0BA0 simultaneously?

The maximum current is 700 mA for the entire module as well as for an individual channel.

How much input address space should I reserve for 6ES7131-6BF01-0BA0 with quality information?

Reserve one byte for the input values and one additional byte for quality information.

Can I adjust the filtering independently for noisy contacts on 6ES7131-6BF01-0BA0?

The input delay is selectable for each channel from 0.05 to 20 ms.

Will 6ES7131-6BF01-0BA0 distinguish a broken sensor wire from a normal channel indication?

Wire-break diagnostics operate at module level, while the green channel LEDs indicate the individual input states.

What leakage-current limit applies to a two-wire sensor connected to 6ES7131-6BF01-0BA0?

The maximum permissible quiescent current is 1.5 mA.

Can 6ES7131-6BF01-0BA0 operate below freezing in a horizontal rack?

Hardware from FS02 supports horizontal operation down to −30 °C.

Compatibility & Ordering Notes
Before ordering 6ES7131-6BF01-0BA0: Choose an A0 BaseUnit, allow for the shared 700 mA sensor budget and restore the required channel delays and module diagnostics.

Compatibility Checklist for 6ES7131-6BF01-0BA0

  • Use an A0 BaseUnit and the CC01 module color assignment.
  • For three-wire wiring, provide AUX terminals or a potential distributor module.
  • For four-wire wiring, add the specified potential distributor module.
  • Use TIA Portal V14 or later; the 2019 module manual specifies HSP 0222 for that version.
Hot Selling Models
ABB S281K
3RT1026-1BB44 3RH1921-1HA22
8258791
2ZM-1,6-PKZ2
6DS1211-8AA
LS85/2S
9A615.3
3RV2011-0BA15
99.80.0.230.98
140M-C2E-A40
KH40 T204/01
6DS1213-8AA
CR-M230AC4 1SVR405613R3000
PNOZV3s24VDC
136425/1056770/010