Siemens 6ES7122-1BB10-0AA0 SIMATIC ET 200L-SC 2DO 24 V DC 2 A Electronic Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use a compatible TB 16SC or TB 16IM-SC base.
- Verify the load-supply polarity before switching on.
- Apply the separate per-channel and total-current limits.
- Allow for the output pulse when switching L+ mechanically and for the stated short-circuit recovery measures.
6ES7122-1BB10-0AA0 SIMATIC ET 200L-SC 2DO 24 V DC 2 A Electronic Module
A narrow Smart Connect output module with two 24 V DC channels, nominal 2 A output current and electronic short-circuit protection.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7122-1BB10-0AA0 |
| Product Type | SC digital-output electronic module |
| Core Function | Switching DC field loads |
| Application | ET 200L-SC and ET 200L-SC IM-SC stations |
Two DC channels
The module switches two loads with a nominal 2 A channel rating.
Smart Connect base
Installation uses a compatible TB 16SC or TB 16IM-SC terminal block.
Load protection
Electronic output protection limits short-circuit current.
Product Overview
6ES7122-1BB10-0AA0 provides two DC output channels in an ET 200L Smart Connect installation. It plugs into the compatible terminal block and receives its load supply through the base.
The module has green channel-status LEDs, electronic output short-circuit protection and no diagnostic or interrupt function. Output loading must respect both the temperature-dependent channel range and the module total-current limit.
Key Functions
Switch DC actuators
The two channels provide a nominal 2 A output at a rated 24 V DC load supply.
Indicate channel status
A green LED is provided for each output channel.
Limit an output short circuit
Electronic protection acts on the output, with a defined recovery procedure needed after some full-load faults.
Official Specifications
| Digital outputs | 2 |
|---|---|
| Rated load supply | 24 V DC |
| Nominal output current | 2 A per channel |
| Permissible signal-1 current | 5 mA–2.4 A at 0–40 °C; 5 mA–1.8 A at 40–60 °C |
| Maximum module output total | 3 A up to 40 °C; 2 A up to 60 °C |
| Minimum signal-1 output voltage | L+ minus 0.5 V |
| Maximum signal-0 residual current | 0.6 mA |
| Output delays with resistive load | Rising: 200 µs maximum; falling: 1.3 ms maximum |
| Maximum switching frequency | Resistive: 100 Hz; inductive: 0.2 Hz at 1 A or 0.1 Hz at 2 A; lamp: 1 Hz |
| Maximum lamp load | 10 W |
| Load-resistance range | 12 Ω–4.8 kΩ |
| Output short-circuit threshold | 2.8–7.2 A typical |
| No-load current from L+ | 6 mA |
| Typical module power loss | 0.9 W |
| Maximum cable length | 600 m unshielded; 1000 m shielded |
| Channel and bus isolation | No galvanic isolation between channels or between channels and SC bus |
| Channel indication | One green LED per channel |
| Permitted terminal-block insertion count | 20 maximum |
| Module dimensions | 10 × 64 × 51 mm (W × H × D) |
| Approximate weight | 15 g |
Frequently Asked Questions
Which terminal-block systems accept 6ES7122-1BB10-0AA0?
The module is listed for TB 16SC and TB 16IM-SC Smart Connect terminal blocks.
What polarity check is essential before powering 6ES7122-1BB10-0AA0?
Check 1L+/1M and 2L+/2M on the terminal block because reversed load-supply polarity can activate connected actuators.
Can both channels of 6ES7122-1BB10-0AA0 continuously carry 2 A at 60 °C?
The module total is limited to 2 A up to 60 °C, and each channel must also remain within its temperature-dependent current range.
Why might a load fail to restart after a short circuit on 6ES7122-1BB10-0AA0?
Full-load restart is not guaranteed after a short circuit, so change the output signal, interrupt the module load supply or temporarily disconnect the load.
Does 6ES7122-1BB10-0AA0 electrically isolate the two outputs from each other?
There is no galvanic isolation between the channels or between the channels and the SC bus.
Can I use 6ES7122-1BB10-0AA0 to generate diagnostic interrupts for an output fault?
The module has no interrupt or diagnostic function and provides green channel-status LEDs.
What transient can appear if I switch the L+ supply of 6ES7122-1BB10-0AA0 with a mechanical contact?
A disturbing output pulse can increase from 5 µs at rated current to 100 µs at a 10 mA load, using a 10 V threshold.