Overview
Siemens · SIMATIC S5-135U/155U
6ES5465-4UA13 465 Analog Input Module
Siemens 6ES5465-4UA13 is the SIMATIC S5 465 non-isolated analog input module in compact U design, providing sixteen voltage or current inputs and requiring plug-in measuring-range modules.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES5465-4UA13 |
| Product Type | SIMATIC S5 analog input module |
| Core Function | Converts grouped analog field signals into digital process values for the controller |
| Application or Compatible Series | SIMATIC S5-135U and S5-155U systems |
Range-Module Inventory
Record the exact 6ES5498-1AAxx measuring-range module fitted to each four-channel group.
Common-Potential Check
Keep sensor reference potentials within the permitted difference because the input circuits are non-isolated.
Migration Scope
Match every signal type, channel count and wiring method to the selected adapter and target input module.
Product Overview
Siemens 6ES5465-4UA13 is the SIMATIC S5 465 non-isolated analog input module in compact U design, providing sixteen voltage or current inputs and requiring plug-in measuring-range modules.
Four plug-in measuring-range modules configure sixteen voltage or current inputs in groups of four. The module can acquire eight Pt100 resistance measurements when fitted and wired for the documented range. Selectable fifty- or sixty-hertz integration settings suppress mains-frequency interference during conversion.
Key Functions
Grouped Multi-Range Acquisition
Four plug-in measuring-range modules configure sixteen voltage or current inputs in groups of four.
Pt100 Measurement Mode
The module can acquire eight Pt100 resistance measurements when fitted and wired for the documented range.
Line-Frequency Integration
Selectable fifty- or sixty-hertz integration settings suppress mains-frequency interference during conversion.
Official Specifications
| Voltage and Current Input Capacity | 16 channels |
|---|---|
| Pt100 Measurement Capacity | 8 resistance inputs |
| Measuring-Range Module Allocation | 1 module per 4 input channels; 4 modules maximum |
| Supported Measuring-Range Modules | 6ES5498-1AA11, -1AA21, -1AA31, -1AA41, -1AA51, -1AA61 and -1AA71 |
| Available Signal Ranges | +/-50 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V, +/-20 mA, 4 to 20 mA and Pt100 |
| Measured-Value Format | 13-bit two's-complement or 12-bit magnitude plus sign |
| Nominal Digital Representation | +/-2048 units; 512 to 2560 units for 4 to 20 mA |
| Measurement Principle | Integrating |
| Conversion Method | Dual-slope voltage-to-time conversion |
| Maximum Reference-Potential Difference | +/-1 V between sensor and module reference potentials and between channel sensor references |
| Backplane Supply and Current | 5 V DC +/-5%; 150 mA typical |
| Two-Wire Transmitter Supply | 24 V DC load supply; 20 mA maximum per transmitter |
| Enable and Wire-Break-Test Connections | 24 V DC; approximately 5 mA for each connection |
| Integration Time | 20 ms at 50 Hz; 16.67 ms at 60 Hz |
| Encoding Time per Measured Value | 60 ms at 50 Hz; 50 ms at 60 Hz |
| Maximum Acquisition Delay at 50 Hz | Approximately 0.48 s for 8 values or 0.96 s for 16 values |
| Input Impedance by Range | At least 10 Mohm for +/-50 mV, +/-500 mV and Pt100; 90 kohm at +/-1 V; 50 kohm at +/-5 V and +/-10 V; 25 ohm at +/-20 mA; 31.25 ohm at 4 to 20 mA |
| Configurable Wire-Break Diagnostics | Available for +/-50 mV, +/-500 mV and Pt100 ranges |
| Input Voltage Withstand | +/-18 V continuous; 75 V for 1 ms at a 1:20 duty ratio |
| Interference Rejection at 50 or 60 Hz | At least 86 dB common-mode and at least 40 dB differential-mode |
Frequently Asked Questions
How do I plan channel capacity for 6ES5465-4UA13?
Use up to sixteen voltage or current channels, or eight Pt100 resistance inputs in the documented configuration.
Which measuring-range module should I fit to 6ES5465-4UA13?
Select the exact 6ES5498-1AAxx module for the required signal range, with one range module serving each group of four inputs.
Can I connect two-wire 4 to 20 mA transmitters to 6ES5465-4UA13?
Yes, use the specified two-wire range arrangement with a 24-volt load supply and no more than 20 milliamperes per transmitter.
How should I manage reference potentials when wiring 6ES5465-4UA13?
Keep the difference between sensor and module references and between channel sensor references within plus or minus one volt.
What scan delay should I allow for 6ES5465-4UA13 at 50 Hz?
Allow about 0.48 seconds for eight values or 0.96 seconds for sixteen values at the fifty-hertz setting.
When can I enable wire-break monitoring on 6ES5465-4UA13?
Wire-break diagnostics can be configured for the plus or minus 50-millivolt, plus or minus 500-millivolt and Pt100 ranges.
Can I replace 6ES5465-4UA13 directly with one S7 analog module?
No direct successor is specified, so choose the migration adapter and target input hardware for the installed ranges, wiring method and required channel count.
Compatibility & Ordering Notes
Compatibility Checklist
- Use one matching 6ES5498-1AAxx measuring-range module for each four-channel group and verify all four installed positions.
- Keep all sensor reference-potential differences within plus or minus one volt because the analog inputs are non-isolated.
- For Pt100 service, preserve the documented eight-input wiring and the restrictions that apply to the upper channel group.