Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es5465 4ua13 simatic s5 465 analog input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S5 6ES5465-4UA13 465 Analog Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S5-135U/155U

6ES5465-4UA13 465 Analog Input Module

Siemens 6ES5465-4UA13 is the SIMATIC S5 465 non-isolated analog input module in compact U design, providing sixteen voltage or current inputs and requiring plug-in measuring-range modules.

At a Glance

Brand Siemens
Model 6ES5465-4UA13
Product Type SIMATIC S5 analog input module
Core Function Converts grouped analog field signals into digital process values for the controller
Application or Compatible Series SIMATIC S5-135U and S5-155U systems

Range-Module Inventory

Record the exact 6ES5498-1AAxx measuring-range module fitted to each four-channel group.

Common-Potential Check

Keep sensor reference potentials within the permitted difference because the input circuits are non-isolated.

Migration Scope

Match every signal type, channel count and wiring method to the selected adapter and target input module.

Product Overview

Siemens 6ES5465-4UA13 is the SIMATIC S5 465 non-isolated analog input module in compact U design, providing sixteen voltage or current inputs and requiring plug-in measuring-range modules.

Four plug-in measuring-range modules configure sixteen voltage or current inputs in groups of four. The module can acquire eight Pt100 resistance measurements when fitted and wired for the documented range. Selectable fifty- or sixty-hertz integration settings suppress mains-frequency interference during conversion.

Ordering focus: confirm the complete order number, S5-135U or S5-155U rack, installed 6ES5498 measuring-range modules, channel signal types, common-potential wiring, line-frequency setting, front connector and migration plan.
Key Functions

Grouped Multi-Range Acquisition

Four plug-in measuring-range modules configure sixteen voltage or current inputs in groups of four.

Pt100 Measurement Mode

The module can acquire eight Pt100 resistance measurements when fitted and wired for the documented range.

Line-Frequency Integration

Selectable fifty- or sixty-hertz integration settings suppress mains-frequency interference during conversion.

Official Specifications
Voltage and Current Input Capacity 16 channels
Pt100 Measurement Capacity 8 resistance inputs
Measuring-Range Module Allocation 1 module per 4 input channels; 4 modules maximum
Supported Measuring-Range Modules 6ES5498-1AA11, -1AA21, -1AA31, -1AA41, -1AA51, -1AA61 and -1AA71
Available Signal Ranges +/-50 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V, +/-20 mA, 4 to 20 mA and Pt100
Measured-Value Format 13-bit two's-complement or 12-bit magnitude plus sign
Nominal Digital Representation +/-2048 units; 512 to 2560 units for 4 to 20 mA
Measurement Principle Integrating
Conversion Method Dual-slope voltage-to-time conversion
Maximum Reference-Potential Difference +/-1 V between sensor and module reference potentials and between channel sensor references
Backplane Supply and Current 5 V DC +/-5%; 150 mA typical
Two-Wire Transmitter Supply 24 V DC load supply; 20 mA maximum per transmitter
Enable and Wire-Break-Test Connections 24 V DC; approximately 5 mA for each connection
Integration Time 20 ms at 50 Hz; 16.67 ms at 60 Hz
Encoding Time per Measured Value 60 ms at 50 Hz; 50 ms at 60 Hz
Maximum Acquisition Delay at 50 Hz Approximately 0.48 s for 8 values or 0.96 s for 16 values
Input Impedance by Range At least 10 Mohm for +/-50 mV, +/-500 mV and Pt100; 90 kohm at +/-1 V; 50 kohm at +/-5 V and +/-10 V; 25 ohm at +/-20 mA; 31.25 ohm at 4 to 20 mA
Configurable Wire-Break Diagnostics Available for +/-50 mV, +/-500 mV and Pt100 ranges
Input Voltage Withstand +/-18 V continuous; 75 V for 1 ms at a 1:20 duty ratio
Interference Rejection at 50 or 60 Hz At least 86 dB common-mode and at least 40 dB differential-mode
Frequently Asked Questions

How do I plan channel capacity for 6ES5465-4UA13?

Use up to sixteen voltage or current channels, or eight Pt100 resistance inputs in the documented configuration.

Which measuring-range module should I fit to 6ES5465-4UA13?

Select the exact 6ES5498-1AAxx module for the required signal range, with one range module serving each group of four inputs.

Can I connect two-wire 4 to 20 mA transmitters to 6ES5465-4UA13?

Yes, use the specified two-wire range arrangement with a 24-volt load supply and no more than 20 milliamperes per transmitter.

How should I manage reference potentials when wiring 6ES5465-4UA13?

Keep the difference between sensor and module references and between channel sensor references within plus or minus one volt.

What scan delay should I allow for 6ES5465-4UA13 at 50 Hz?

Allow about 0.48 seconds for eight values or 0.96 seconds for sixteen values at the fifty-hertz setting.

When can I enable wire-break monitoring on 6ES5465-4UA13?

Wire-break diagnostics can be configured for the plus or minus 50-millivolt, plus or minus 500-millivolt and Pt100 ranges.

Can I replace 6ES5465-4UA13 directly with one S7 analog module?

No direct successor is specified, so choose the migration adapter and target input hardware for the installed ranges, wiring method and required channel count.

Compatibility & Ordering Notes
Before ordering 6ES5465-4UA13: confirm the complete order number, S5-135U or S5-155U rack, installed 6ES5498 measuring-range modules, channel signal types, common-potential wiring, line-frequency setting, front connector and migration plan.

Compatibility Checklist

  • Use one matching 6ES5498-1AAxx measuring-range module for each four-channel group and verify all four installed positions.
  • Keep all sensor reference-potential differences within plus or minus one volt because the analog inputs are non-isolated.
  • For Pt100 service, preserve the documented eight-input wiring and the restrictions that apply to the upper channel group.
  • Treat Siemens S7 adapter combinations as migration paths rather than plug-in direct replacements.
Hot Selling Models
S402 M C13 2CCS572001R0134
4-120M-10N 1009671000
LR-1/4-D-7-I-MINI
GC-U1 AD 602.1137.103
X4V
QST-10-6
7000-74701-7770300
7000-40021-0340300
4000-68000-0060000
PZEX4V1sec4S
6ES5482-8MA13
BK-LK-2MBD
3RU1126-4DB1
H3DS-ML
6ES7921-3AA00-0AA0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.