Overview
SIMATIC S5-135U/155U

6ES5436-4UA12 SIMATIC S5 16-Channel AC Digital Input Module

A sixteen-channel AC input module with two isolated groups of eight, defined switching thresholds and front-connector enable wiring.

At a Glance

Brand Siemens
Model 6ES5436-4UA12
Product Type AC digital input module
Core Function Acquiring 115–230 V AC switching signals
Application SIMATIC S5 U peripheral racks

AC signal detection

Defined high and low voltage bands distinguish field switching states.

Grouped electrical isolation

Two groups of eight inputs isolate the field circuits from one another.

Long field wiring

The input circuit permits extended shielded or unshielded sensor cable runs within the stated limits.

Product Overview

6ES5436-4UA12 connects AC field switching signals to the S5 peripheral bus.

The sixteen channels are divided into two isolated groups, with rated operation from 115 to 230 V AC and different positive- and negative-edge input delays.

Ordering focus: Match the AC field voltage, group wiring, front-connector enable bridge and permitted simultaneous input load.
Key Functions

AC signal detection

Defined high and low voltage bands distinguish field switching states.

Grouped electrical isolation

Two groups of eight inputs isolate the field circuits from one another.

Long field wiring

The input circuit permits extended shielded or unshielded sensor cable runs within the stated limits.

Official Specifications
Rated input supply 115–230 V AC at 47–63 Hz
Input allocation 16 channels in two isolated groups of eight
Low-state voltage 0–60 V AC
High-state voltage 90–264 V AC
Typical input current 15 mA at 115 V AC; 25 mA at 230 V AC
Maximum input pulse frequency 20 Hz
Positive-edge delay Typically 5 ms; range 2–15 ms
Negative-edge delay Typically 20 ms; range 10–25 ms
Typical input resistance 10 kΩ
Simultaneity with ventilation 100%
Simultaneity without ventilation 75% at 230 V AC; 100% up to 35 °C or at 115 V AC
Maximum sensor cable length 600 m unshielded; 1,000 m shielded
Logic-bus demand 5 V DC; typically 100 mA
Rated operating dissipation 3.5 W at 115 V AC; 17 W at 230 V AC
Enable input F+/F− bridge in the front connector
Isolation test voltage 2,000 V AC group-to-group; 1,500 V AC group-to-earth
Dimensions 40 × 255 × 195 mm (W × H × D)
Approximate mass 0.55 kg
Frequently Asked Questions

Can I use 24 V DC field signals directly with 6ES5436-4UA12?

The input channels are rated for 115–230 V AC rather than 24 V DC.

What voltage is required for a high input state on 6ES5436-4UA12?

A high state requires an input voltage within the specified 90–264 V AC band.

How are the sixteen inputs on 6ES5436-4UA12 electrically grouped?

The channels form two isolated groups with eight inputs in each group.

Can a two-wire BERO sensor drive an input on 6ES5436-4UA12?

The input circuit permits a two-wire BERO connection.

Can I use 6ES5436-4UA12 to count a 50 Hz pulse train?

The specified maximum input pulse frequency is 20 Hz.

Must I reduce the active-channel load when using 6ES5436-4UA12 without ventilation?

At 230 V AC without ventilation the simultaneity factor is 75%, increasing to 100% up to 35 °C.

Which enable connection is required at the front connector of 6ES5436-4UA12?

Fit the specified bridge for the F+/F− enable input in the front connector.

Compatibility & Ordering Notes
Before ordering 6ES5436-4UA12: Match the AC field voltage, group wiring, front-connector enable bridge and permitted simultaneous input load.

Before installation

  • Select an AC input arrangement with the correct 115–230 V field voltage and isolated group wiring.
  • Fit the front-connector enable bridge and observe the defined signal thresholds.
  • Apply the unventilated simultaneity limit at 230 V AC when sizing the active input load.
  • Keep field wiring within the shielded or unshielded cable-length limit and follow the rack installation arrangement.
Hot Selling Models
6GK1543-1AA01 6ES5376-1AA21 6ES5491-0LB11
284-604
DILA-XHI22
NH3GG50V500
PRO-M 8951390000
QUINT-PS-3x400-500AC/24DC/10
ADVU-25-10-PA
30K02PSK-TSL
WT9-2P451 1018299
M08EC-POC15B-S49G BES013K
813-D02-R16-62-12-02
G04EC-POC08B-S26G
3004016
QE-022-PS-11L
BN3081.63/61 0048701

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.