Overview
SIEMENS SITOP PSU2200

6EP3332-3SA00-0AY0 SITOP PSU2200 24 V DC 3 A Power Supply

A compact PSU2200 with a nominal 3 A output, wide-range single-phase input and a 27 mm-wide DIN-rail enclosure.

At a Glance

Brand Siemens
Model 6EP3332-3SA00-0AY0
Product Type Regulated AC/DC power supply
Core Function Providing isolated DC control power
Application Control-cabinet power distribution

Adjustable DC output

The potentiometer covers 21.6–26 V DC.

Mains interruption buffering

At rated current and 230 V AC input, minimum buffering is 60 ms.

Convection installation

The enclosure needs clearance above, below and on both sides.

Product Overview

6EP3332-3SA00-0AY0 supplies a stabilized 24 V DC control circuit from a single-phase AC source. The PSU2200 uses a wide-range input and has a nominal 3 A output with front-potentiometer adjustment.

The supply combines input/output isolation, output current limiting and automatic short-circuit recovery. Temperature-dependent derating applies at both low and high ambient temperatures.

Ordering focus: Match the 3 A nominal load, AC input range, temperature derating and required ventilation clearances.
Key Functions

Regulate the DC circuit

The output can be set from 21.6 to 26 V DC.

Bridge a short input interruption

Minimum rated-load buffering is 60 ms at 230 V AC input.

Recover from a short circuit

The output uses constant-current limiting and hiccup operation below 80% voltage, with automatic restart when the fault is removed.

Official Specifications
Nominal AC input 1-phase, 100–240 V AC
Permitted input range 85–264 V AC
Input frequency 47–63 Hz
Nominal output 24 V DC, 3 A
Output adjustment 21.6–26 V DC
Typical active output power 75 W
Overall output-voltage tolerance 2%
Output ripple and peaks 120 mV typical; 360 mV maximum
Minimum mains buffering 60 ms at 230 V AC and rated output current
Typical efficiency 89%
Typical rated-load power loss 9 W
Maximum inrush current 50 A at 25 °C
Overvoltage protection Below 33.6 V; latch mode
Current-limit range 105–133% of rated load current; automatic recovery
Low-temperature derating 1%/K from −10 to −20 °C
High-temperature derating 1.67%/K above 40 °C at 115 V AC; 2.5%/K above 50 °C at 230 V AC
Operating temperature −20 to +70 °C; natural convection
Protection IP20; Class I
Enclosure dimensions 27 × 124 × 102 mm (W × H × D)
Net weight 0.22 kg
Official source:Siemens product data sheet
Frequently Asked Questions

Can 6EP3332-3SA00-0AY0 remain supplied when the AC input falls to 85 V?

The permitted AC input range extends from 85 to 264 V.

How much space should I leave around 6EP3332-3SA00-0AY0 for cooling?

Leave 50 mm above and below the enclosure and 10 mm on each side.

Does 6EP3332-3SA00-0AY0 require derating below −10 °C?

Reduce the output by 1% per kelvin between −10 and −20 °C.

How does the hot-cabinet derating of 6EP3332-3SA00-0AY0 depend on the input voltage?

Derating is 1.67% per kelvin above 40 °C at 115 V AC or 2.5% per kelvin above 50 °C at 230 V AC.

Can I wall-mount 6EP3332-3SA00-0AY0 instead of using a DIN rail?

The supply is designed to snap onto an EN 60715 35 mm DIN rail and does not support wall mounting.

Which feeder protection is recommended for 6EP3332-3SA00-0AY0?

Use the recommended 16 A characteristic-B miniature circuit breaker in the feeder.

What indicates normal DC output operation on 6EP3332-3SA00-0AY0?

A green 24 V OK LED indicates normal output operation.

Compatibility & Ordering Notes
Before ordering 6EP3332-3SA00-0AY0: Select the PSU2200 3 A supply for the actual DC load, provide protective earth and preserve the specified cooling spaces.

Compatibility Checklist for 6EP3332-3SA00-0AY0

  • Use a single-phase AC input within the permitted range.
  • Include low- and high-temperature derating in the load calculation.
  • Reserve 50 mm top/bottom and 10 mm left/right clearance.
  • Use the specified DIN rail and recommended feeder protection.
Hot Selling Models
T4VH33520ZM20
EL6900
MGS200
6SL3162-2MB00-0AC0
WL9-2N131
KS2424
PVBS 157B9101
157B7022 PVG32
157B9023
KAS-80-C-6.5/20-S KAS80C-6.5/20S
73K-PU-1FR-C-02
T175N22E0C61
DNC-40-25-PPV-A
02.1-480-008
Bi3-EG12SK-AP6X/S330

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.