Overview
- Calculate load current using the applicable ambient-temperature derating.
- Adjust output voltage within the permitted range before connecting voltage-sensitive loads.
- Maintain the protective-earth connection and correct DC polarity when using a DC source.
- Allow the specified natural-convection clearance and use suitable feeder protection.
6EP1322-5BA10 SITOP PSU100C 12 V 6.5 A Power Supply
A 78 W, 12 V supply with adjustable output, AC/DC input and temperature-dependent output-current limits.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6EP1322-5BA10 |
| Product Type | Compact stabilized power supply |
| Core Function | Supplying regulated DC to control loads |
| Application | Compact DIN-rail automation cabinets |
Adjustable 12 V output
The output potentiometer covers 10.5–12.9 V.
Temperature-dependent loading
Output current must be reduced above 55 °C.
Electronic overload recovery
The supply uses electronic shutdown with automatic restart after a short-circuit event.
Product Overview
6EP1322-5BA10 supplies regulated 12 V DC at a nominal output current of 6.5 A.
The compact PSU100C combines removable input terminals, an adjustable output and automatic restart after an electronic protection shutdown.
Key Functions
Adjustable 12 V output
The output potentiometer covers 10.5–12.9 V.
Temperature-dependent loading
Output current must be reduced above 55 °C.
Electronic overload recovery
The supply uses electronic shutdown with automatic restart after a short-circuit event.
Official Specifications
| AC input range | 85–264 V AC; 47–63 Hz; rated range 100–230 V |
|---|---|
| DC input range | 110–300 V DC |
| Nominal output | 12 V DC, 6.5 A; 78 W |
| Adjustment range | 10.5–12.9 V |
| High-temperature current limit | Derating 1.6%/K from +55 to +70 °C; 4.9 A at +70 °C |
| Maximum input current | 1.6 A at 100 V; 0.8 A at 230 V |
| Maximum inrush | 31 A at 25 °C; maximum I²t 3 A²·s |
| Minimum mains buffering | 20 ms at 230 V input and rated output current |
| Residual ripple | 200 mV maximum; 80 mV typical |
| Startup timing | Maximum response delay 1 s; typical voltage rise 500 ms |
| Efficiency and typical loss | 86%; 12.5 W at rated output |
| Maximum no-load loss | 0.75 W |
| Protection response | Electronic shutdown and automatic restart; typical limiting current 7.2 A |
| Electrical protection | Class I; isolated SELV output; IP20 |
| Operating ambient | −20 to +70 °C with natural convection |
| Storage and transport ambient | −40 to +85 °C |
| Power-terminal conductors | 0.5–2.5 mm²; removable input screw terminal |
| Required convection clearance | 50 mm above and below; no lateral clearance |
| Dimensions and net mass | 52.5 × 80 × 100 mm (W × H × D); 0.32 kg |
Frequently Asked Questions
Can 6EP1322-5BA10 deliver 6.5 A continuously at 70 °C?
At 70 °C the stated rated output current is reduced to 4.9 A.
At which temperature does output derating begin for 6EP1322-5BA10?
Derating begins above 55 °C at 1.6% per kelvin.
Can the input terminal of 6EP1322-5BA10 be removed during maintenance?
The input uses a removable screw-terminal connection.
How slowly does the output of 6EP1322-5BA10 rise during startup?
The typical output-voltage rise time is 500 ms.
What does the green indicator on 6EP1322-5BA10 show?
The green LED indicates that the output voltage is OK.
How much no-load power loss should I allow for 6EP1322-5BA10?
The maximum stated no-load power loss is 0.75 W.
How does 6EP1322-5BA10 recover after its electronic short-circuit shutdown?
The supply attempts an automatic restart.