Siemens 6EP1322-5BA10 SITOP PSU100C 12 V 6.5 A Power Supply
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Calcula currentem oneris utendo deductione temperaturae ambientis applicabili.
- Adiusta tensionem exire intra ambitum permissum antequam onera sensibilia ad tensionem conectuntur.
- Mantere connexionem terrae protectivae et polaritytem directam correctam quando utiturur fonte directa.
- Permittere spatium specificatum pro convectione naturali et uti protectione idonea pro conductibus.
6EP1322-5BA10 SITOP PSU100C 12 V 6.5 A Power Supply
A 78 W, 12 V supply with adjustable output, AC/DC input, and temperature-dependent output-current limits.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6EP1322-5BA10 |
| Typus Producti | Compact stabilized power supply |
| Functio principalis | Supplying regulated DC to control loads |
| Applicatio | Compact DIN-rail automation cabinets |
Adjustable 12 V output
The output potentiometer covers 10.5–12.9 V.
Onus dependentes a temperatura
Output current must be reduced above 55 °C.
Electronic overload recovery
The supply uses electronic shutdown with automatic restart after a short-circuit event.
Product Overview
6EP1322-5BA10 supplies regulated 12 V DC at a nominal output current of 6.5 A.
The compact PSU100C combines removable input terminals, an adjustable output and automatic restart after an electronic protection shutdown.
Key Functions
Adjustable 12 V output
The output potentiometer covers 10.5–12.9 V.
Onus dependentes a temperatura
Output current must be reduced above 55 °C.
Electronic overload recovery
The supply uses electronic shutdown with automatic restart after a short-circuit event.
Official Specifications
| Intervalum Tensionis Alternantis Ingressus | 85–264 V AC; 47–63 Hz; rated range 100–230 V |
|---|---|
| Intervalum Tensionis Directae Ingressus | 110–300 V DC |
| Nominal output | 12 V DC, 6.5 A; 78 W |
| Temperatio dolor | 10.5–12.9 V |
| High-temperature current limit | Derating 1.6%/K from +55 to +70 °C; 4.9 A at +70 °C |
| Maximus Correntis Ingressus | 1.6 A at 100 V; 0.8 A at 230 V |
| Inrumpens Maximum | 31 A ad 25 °C; maximum I²t 3 A²·s |
| Bufferisation minimal del rete | 20 ms ad tensionem intrantis 230 V et currentem exitalis nominalem |
| Undulatio Residualis | 200 mV maximum; 80 mV typice |
| Tempus initiationis | Maximum mora responsionis 1 s; typica ascensio tensionis 500 ms |
| Efficienza e perdu tipica | 86 %; 12,5 W ad outputum nominalem |
| Maximum lossus sine onere | 0.75 W |
| Responsio protectionis | Interdictio electronica et reinitiatio automatica; typica currente limitans 7,2 A |
| Tutela Electrica | Classis I; outputus isolatus SELV; IP20 |
| Ambiens Operativa | −20 usque ad +70 °C cum convectione naturali |
| Ambiens de stockage et de transport | −40 ad +85 °C |
| Conductores terminalium potentiae | 0,5–2,5 mm²; terminalis surculi input removibilis |
| Spatium convectionis necessarium | 50 mm supra et infra; nullum spatium laterale |
| Dimensiones et massa neta | 52.5 × 80 × 100 mm (l × a × p); 0.32 kg |
Quaestiones Frequenter Rogatae
Num 6EP1322-5BA10 potest 6.5 A continuo ad 70 °C praebere?
Ad 70 °C currentis nominis declaratus in output diminuitur ad 4.9 A.
Ad quam temperaturam diminutio output incipit pro 6EP1322-5BA10?
Diminutio incipit supra 55 °C ad 1.6% per kelvin.
Num terminus input 6EP1322-5BA10 removi potest dum operatio manutenentiae agitur?
Input usus connexionem ad vitium avulsibilem per vitem.
Quam lente output 6EP1322-5BA10 crescit dum initium fit?
Tempus typicalis ad augendum tensionem exire est 500 ms.
Quid indicat indicator viridis in 6EP1322-5BA10?
Diodus electroluminescens viridis indicat tensionem exire esse bonam.
Quanta potestas amittitur in statu sine onere pro 6EP1322-5BA10?
Maxima potestas amissa in statu sine onere declarata est 0.75 W.
Quomodo 6EP1322-5BA10 recuperat post cessationem automaticam propter curtum circuitum electronicum?
Fons tentat reinitiationem automaticam.