SIEMENS · TELEPERM XP

6DP1230-8CC FUM 230 Analog Transmitter Signal Conditioning Module

The FUM 230 conditions sixteen 0/4 to 20 mA transmitter inputs, supplies supported field transmitters and monitors range and wiring faults.

At a Glance

Brand Siemens
Model 6DP1230-8CC
Product Type sixteen-channel analog transmitter interface module
Core Function Conditions, supplies and monitors 0/4 to 20 mA transmitter signals
Application or Compatible Series TELEPERM XP process-control systems using FUM 230 analog modules

Exact Identification

Match 6DP1230-8CC character by character and confirm the complete FUM 230 Analog Transmitter Signal Conditioning Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The FUM 230 conditions sixteen 0/4 to 20 mA transmitter inputs, supplies supported field transmitters and monitors range and wiring faults.

Sixteen channels accept 0/4 to 20 mA signals in supported two-wire or four-wire circuits. The module provides a 24 V DC supply for compatible field transmitters. Limit evaluation, signal correction, supply monitoring, range supervision and wire-break detection support process applications.

Ordering focus: confirm all sixteen loop assignments, signal ranges, two-wire or four-wire wiring, transmitter supply, limit settings, correction values and redundancy arrangement.
Key Functions

Sixteen Current Inputs

Sixteen channels accept 0/4 to 20 mA signals in supported two-wire or four-wire circuits.

Integrated Transmitter Supply

The module provides a 24 V DC supply for compatible field transmitters.

Channel Monitoring and Redundancy

Limit evaluation, signal correction, supply monitoring, range supervision and wire-break detection support process applications.

Official Specifications
Analog Input Channels 16
Current Input Range 0/4 to 20 mA
Two-Wire Transmitter Circuit Supported
Four-Wire Transmitter Circuit Supported
Transmitter Supply 24 V DC
Limit Values per Channel 4
Signal Correction Supported
Transmitter-Supply Monitoring Supported
Range-Overshoot Monitoring Supported
Range-Undershoot Monitoring Supported
Wire-Break Monitoring Supported
Redundant Use Suitable
Net Weight 0.55 kg
Listed Successor 6DP1230-7BA
Frequently Asked Questions

How many transmitter loops can 6DP1230-8CC process?

Sixteen analog current-input channels are available.

Which signal ranges can be wired to 6DP1230-8CC?

The channels accept 0 to 20 mA or 4 to 20 mA transmitter signals.

Can 6DP1230-8CC power connected field transmitters?

Yes; a 24 V DC transmitter supply is integrated for supported two-wire or four-wire circuits.

How many alarm limits are available per channel on 6DP1230-8CC?

Four limit values can be assigned to each channel.

Which faults can 6DP1230-8CC monitor during operation?

It monitors transmitter supply, measuring-range overshoot, measuring-range undershoot and wire break.

Is redundant operation possible with 6DP1230-8CC?

Yes; the module is designated as suitable for redundant use.

What must be matched before replacing 6DP1230-8CC?

Confirm every loop range, two-wire or four-wire connection, channel limit, correction setting, redundancy role and hardware revision.

Compatibility & Ordering Notes
Before ordering 6DP1230-8CC: confirm all sixteen loop assignments, signal ranges, two-wire or four-wire wiring, transmitter supply, limit settings, correction values and redundancy arrangement.

Compatibility Checklist

  • Use only 0/4 to 20 mA transmitter circuits that match the configured channel type.
  • Verify the 24 V DC transmitter-supply wiring and every configured monitoring limit.
  • Preserve all loop engineering, correction values and redundancy settings before replacement.
Hot Selling Models
45493 2437068
D-3/4I-1A
3TW1FG350
D20 WMZS3D20
3RA1923-2A
D20WMZS3D20
3RV2021-4AA10 3RV2901-2E
ElfaEP101 B6 230/400V
3RP1505-1BW30
ABB CAL5-11 1SBN010020R1011
MFSW-230-50/60
9000-41034-0100600
3RH2131-1AP00
5SL4106-7
VKHM-W-5/4

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.