Overview
Siemens • SIMATIC ET 200SP HA
6DL1133-6EW00-0EH1 SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module
The SIMATIC ET 200SP HA configurable I/O module provides sixteen channels that can be assigned for current or HART measurement, digital input, counter or 24 V DC digital output duties.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DL1133-6EW00-0EH1 |
| Product Type | Configurable 16-channel analog/digital I/O module |
| Core Function | Processes current, HART, digital input, counter and digital output signals by channel |
| Application or Compatible Series | ET 200SP HA process stations using H1, M1, P0 or N0 terminal blocks |
Exact Identification
Match 6DL1133-6EW00-0EH1 character by character and confirm the complete SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The SIMATIC ET 200SP HA configurable I/O module provides sixteen channels that can be assigned for current or HART measurement, digital input, counter or 24 V DC digital output duties.
Sixteen channels can be assigned to the supported analog and digital operating modes. The current inputs support 4 to 20 mA HART communication for compatible field instruments. Approved terminal blocks and an M1 configuration support redundancy-oriented ET 200SP HA designs.
Key Functions
Channel-by-Channel Configuration
Sixteen channels can be assigned to the supported analog and digital operating modes.
HART Process Integration
The current inputs support 4 to 20 mA HART communication for compatible field instruments.
High-Availability Support
Approved terminal blocks and an M1 configuration support redundancy-oriented ET 200SP HA designs.
Official Specifications
| Firmware Version | V1.1; update supported |
|---|---|
| Identification Data | I&M0 to I&M3 |
| Reparameterization in RUN | Supported |
| Rated Supply Voltage | 24 V DC |
| Permissible Supply Range | 19.2 to 28.8 V DC |
| Reverse-Polarity Protection | Yes |
| Rated Current without Sensor Supply | 80 mA |
| Maximum Current without Sensor Supply | 90 mA |
| Sensor Supply Outputs | 16 |
| Minimum Sensor Supply Voltage | 18.2 V |
| Maximum Module Current | 2 A |
| Maximum Shielded Cable Length | 1,000 m |
| Maximum Unshielded Cable Length | 600 m |
| Analog Inputs | 16 current inputs |
| Current Measurement Ranges | 0 to 10 mA; 0 to 20 mA; 4 to 20 mA; 4 to 20 mA HART |
| Input Resistance | 250 ohms |
| Current Input Destruction Limit | 30 mA |
| Measurement Resolution | 16 bits including sign |
| Linearity Error | ±0.01% |
| Repeat Accuracy | ±0.05% |
Frequently Asked Questions
Which terminal blocks work with 6DL1133-6EW00-0EH1?
Use the H1, M1, P0 or N0 terminal block selected for the engineered station and redundancy design.
Can 6DL1133-6EW00-0EH1 mix analog and digital channel duties?
Yes; configure each channel only for one supported operating mode and preserve the original channel assignment.
Which HART range should be selected on 6DL1133-6EW00-0EH1?
Choose the 4 to 20 mA HART range for compatible instruments that require digital HART communication.
Can 6DL1133-6EW00-0EH1 be reparameterized while the station is running?
Yes; controlled reparameterization in RUN is supported when the process and project permit it.
How should cable length be planned for 6DL1133-6EW00-0EH1?
Keep shielded runs within 1,000 m and unshielded runs within 600 m while following the plant grounding concept.
What must be saved before replacing 6DL1133-6EW00-0EH1?
Back up every channel mode, measurement range, diagnostics, HART assignment, terminal-block type and redundancy setting.
What should be tested after commissioning 6DL1133-6EW00-0EH1?
Verify all channel values, digital states, counter functions, output loads, HART communication and station diagnostics.
Compatibility & Ordering Notes
Compatibility Checklist
- Match the installed H1, M1, P0 or N0 terminal block.
- Use M1 only where the engineered redundancy configuration requires it.
- Restore every channel operating mode and HART assignment before loop testing.