Conspectus
Siemens • SIMATIC ET 200SP HA
6DL1133-6EW00-0EH1 SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module
The SIMATIC ET 200SP HA configurable I/O module provides sixteen channels that can be assigned for current or HART measurement, digital input, counter or 24 V DC digital output duties.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6DL1133-6EW00-0EH1 |
| Typus Producti | Configurable 16-channel analog/digital I/O module |
| Functio principalis | Processes current, HART, digital input, counter and digital output signals by channel |
| Applicatio vel series compatibiles | ET 200SP HA process stations using H1, M1, P0 or N0 terminal blocks |
Identificatio exacta.
Compare character by character with 6DL1133-6EW00-0EH1 and confirm the full SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The SIMATIC ET 200SP HA configurable I/O module provides sixteen channels that can be assigned for current or HART measurement, digital input, counter or 24 V DC digital output duties.
Sixteen channels can be assigned to the supported analog and digital operating modes. The current inputs support 4 to 20 mA HART communication for compatible field instruments. Approved terminal blocks and an M1 configuration support redundancy-oriented ET 200SP HA designs.
Key Functions
Channel-by-Channel Configuration
Sixteen channels can be assigned to the supported analog and digital operating modes.
HART Process Integration
The current inputs support 4 to 20 mA HART communication for compatible field instruments.
High-Availability Support
Approved terminal blocks and an M1 configuration support redundancy-oriented ET 200SP HA designs.
Official Specifications
| Versio Firmamentalis | V1.1; update supported |
|---|---|
| Identification Data | I&M0 al I&M3 |
| Reparamétrage en marche | Supportata |
| Tensio nominalis supplicii | 24 V DC |
| AMPLITUDO ADMISSIBILIS FONDIS | 19,2 ad 28,8 V CC |
| Protectio contra polaritatem inversam | Ita |
| Currentus nominalis sine alimentatione sensoris | 80 mA |
| Currentus maximus sine alimentatione sensoris | 90 mA |
| Exitus Alimentationis Sensorum | 16 |
| Tensio minima alimentationis sensoris | 18,2 V |
| Maxima currentis modulus | 2 A |
| Maxima Longitudo Cavi Scutati | 1 000 m |
| Longitudo Maximae Cavi Non Scuti | 600 m |
| INPUTUS ANALOGI | 16 introitus currentis |
| Intervalla mensurae currentus | 0 ad 10 mA; 0 ad 20 mA; 4 ad 20 mA; 4 ad 20 mA HART |
| Resistentia input | 250 Ohm |
| Limitis destructionis inputus currentis | 30 mA |
| Resolutio Mensurae | 16 bita, signum inclusum |
| Error Linearitatis | ±0.01% |
| Accurate repetere | ±0.05% |
Quaestiones Frequenter Rogatae
Quae blocos terminalium compatibilia sunt cum 6DL1133-6EW00-0EH1?
Utere bloco terminali H1, M1, P0 aut N0 electo pro statione constructa et pro consilio redundantiae.
Potestne 6DL1133-6EW00-0EH1 commiscere officia canalium analogicorum et digitalium?
Yes; configure each channel only for one supported operating mode and preserve the original channel assignment.
Which HART range should be selected on 6DL1133-6EW00-0EH1?
Choose the 4 to 20 mA HART range for compatible instruments that require digital HART communication.
Can 6DL1133-6EW00-0EH1 be reparameterized while the station is running?
Yes; controlled reparameterization in RUN is supported when the process and project permit it.
How should cable length be planned for 6DL1133-6EW00-0EH1?
Keep shielded runs within 1,000 m and unshielded runs within 600 m while following the plant grounding concept.
What must be saved before replacing 6DL1133-6EW00-0EH1?
Back up every channel mode, measurement range, diagnostics, HART assignment, terminal-block type and redundancy setting.
What should be tested after commissioning 6DL1133-6EW00-0EH1?
Verificare omnes valores canalium, status digitales, functiones contadorum, onera output, communicationem HART et diagnostics stationis.
Compatibility & Ordering Notes
Index Compatibilitatis
- Adaptare blocum terminalis H1, M1, P0 aut N0 installatum.
- Utere M1 solum ubi configuratio redundantiae ingeniosa id requirit.
- Restituere omnem modum operationis canalium et attributionem HART antequam testatur loopus.