Siemens SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module 6DL1133-6EW00-0EH1

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

Siemens • SIMATIC ET 200SP HA

6DL1133-6EW00-0EH1 SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module

The SIMATIC ET 200SP HA configurable I/O module provides sixteen channels that can be assigned for current or HART measurement, digital input, counter or 24 V DC digital output duties.

Ad Primum Aspectum

Nota Siemens
Modellum 6DL1133-6EW00-0EH1
Typus Producti Configurable 16-channel analog/digital I/O module
Functio principalis Processes current, HART, digital input, counter and digital output signals by channel
Applicatio vel series compatibiles ET 200SP HA process stations using H1, M1, P0 or N0 terminal blocks

Identificatio exacta.

Compare character by character with 6DL1133-6EW00-0EH1 and confirm the full SIMATIC ET 200SP HA AI-DI 16/DQ 16x24VDC HART Module designation.

Arrangementum Interfacis

Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.

Configuration Check

Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.

Product Overview

The SIMATIC ET 200SP HA configurable I/O module provides sixteen channels that can be assigned for current or HART measurement, digital input, counter or 24 V DC digital output duties.

Sixteen channels can be assigned to the supported analog and digital operating modes. The current inputs support 4 to 20 mA HART communication for compatible field instruments. Approved terminal blocks and an M1 configuration support redundancy-oriented ET 200SP HA designs.

Focus ordinandi: Confirm the full article number, sixteen-channel modes, current ranges, HART instruments, terminal-block type, redundancy design, cable shielding, and diagnostics.
Key Functions

Channel-by-Channel Configuration

Sixteen channels can be assigned to the supported analog and digital operating modes.

HART Process Integration

The current inputs support 4 to 20 mA HART communication for compatible field instruments.

High-Availability Support

Approved terminal blocks and an M1 configuration support redundancy-oriented ET 200SP HA designs.

Official Specifications
Versio Firmamentalis V1.1; update supported
Identification Data I&M0 al I&M3
Reparamétrage en marche Supportata
Tensio nominalis supplicii 24 V DC
AMPLITUDO ADMISSIBILIS FONDIS 19,2 ad 28,8 V CC
Protectio contra polaritatem inversam Ita
Currentus nominalis sine alimentatione sensoris 80 mA
Currentus maximus sine alimentatione sensoris 90 mA
Exitus Alimentationis Sensorum 16
Tensio minima alimentationis sensoris 18,2 V
Maxima currentis modulus 2 A
Maxima Longitudo Cavi Scutati 1 000 m
Longitudo Maximae Cavi Non Scuti 600 m
INPUTUS ANALOGI 16 introitus currentis
Intervalla mensurae currentus 0 ad 10 mA; 0 ad 20 mA; 4 ad 20 mA; 4 ad 20 mA HART
Resistentia input 250 Ohm
Limitis destructionis inputus currentis 30 mA
Resolutio Mensurae 16 bita, signum inclusum
Error Linearitatis ±0.01%
Accurate repetere ±0.05%
Quaestiones Frequenter Rogatae

Quae blocos terminalium compatibilia sunt cum 6DL1133-6EW00-0EH1?

Utere bloco terminali H1, M1, P0 aut N0 electo pro statione constructa et pro consilio redundantiae.

Potestne 6DL1133-6EW00-0EH1 commiscere officia canalium analogicorum et digitalium?

Yes; configure each channel only for one supported operating mode and preserve the original channel assignment.

Which HART range should be selected on 6DL1133-6EW00-0EH1?

Choose the 4 to 20 mA HART range for compatible instruments that require digital HART communication.

Can 6DL1133-6EW00-0EH1 be reparameterized while the station is running?

Yes; controlled reparameterization in RUN is supported when the process and project permit it.

How should cable length be planned for 6DL1133-6EW00-0EH1?

Keep shielded runs within 1,000 m and unshielded runs within 600 m while following the plant grounding concept.

What must be saved before replacing 6DL1133-6EW00-0EH1?

Back up every channel mode, measurement range, diagnostics, HART assignment, terminal-block type and redundancy setting.

What should be tested after commissioning 6DL1133-6EW00-0EH1?

Verificare omnes valores canalium, status digitales, functiones contadorum, onera output, communicationem HART et diagnostics stationis.

Compatibility & Ordering Notes
Antequam ordinatur 6DL1133-6EW00-0EH1: Confirm the full article number, sixteen-channel modes, current ranges, HART instruments, terminal-block type, redundancy design, cable shielding, and diagnostics.

Index Compatibilitatis

  • Adaptare blocum terminalis H1, M1, P0 aut N0 installatum.
  • Utere M1 solum ubi configuratio redundantiae ingeniosa id requirit.
  • Restituere omnem modum operationis canalium et attributionem HART antequam testatur loopus.
Hot Selling Models
000030
SMT-10F-PS-24V-K0.3L-M12-SA
D-F7P
mk5315 mkc3028bbpkg/g/0.5/as
M12EG-PSC80F-S04G BES01PN
M12MF1-NSC10F-S04G
M12MF1-PSC10F-S04G
516-544-S4-H
516-383-G-SA4-S4-C
RZT1
IF5711 IFK3002-BPKG/US-DPS
305K-PS-C-2-S49
SMT-10M-PS-24V-E-0.3-L-M8D
700-951-0KE00
6ES5498-1AA41

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.