Siemens 3RN2010-2CA30 SIRIUS 24 V AC/DC Thermistor Motor Protection Relay
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Select the automatic-reset version to match the intended motor-control restart sequence.
- Use a 24 V AC/DC control supply within the permitted voltage tolerance.
- Wire the separate NO and NC contacts according to their utilization-category ratings.
- Use the removable push-in terminals with conductor sizes appropriate to ferruled or unferruled wiring.
3RN2010-2CA30 SIRIUS 24 V AC/DC Thermistor Motor Protection Relay
A compact automatic-reset motor-protection relay with a 24 V AC/DC supply, one NO contact, one NC contact and removable push-in terminals.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RN2010-2CA30 |
| Product Type | Thermistor protection evaluation unit |
| Core Function | Motor-temperature protection evaluation |
| Application | Thermistor and bimetallic-switch motor circuits |
Automatic thermal recovery
The automatic-reset version restores its evaluation state after the trip condition clears without a manual or external reset input.
Separate output contacts
One normally open contact and one normally closed contact provide two electrically separated switching paths.
Compact status indication
Ready and tripped LEDs give a local indication of relay state in a 17.5 mm-wide cabinet device.
Product Overview
3RN2010-2CA30 evaluates the motor-temperature sensor circuit and switches separate normally open and normally closed output contacts.
The compact 17.5 mm unit uses automatic reset, provides ready and tripped indications and is suitable for a bimetallic temperature switch as well as the thermistor protection application.
Key Functions
Automatic thermal recovery
The automatic-reset version restores its evaluation state after the trip condition clears without a manual or external reset input.
Separate output contacts
One normally open contact and one normally closed contact provide two electrically separated switching paths.
Compact status indication
Ready and tripped LEDs give a local indication of relay state in a 17.5 mm-wide cabinet device.
Official Specifications
| Control supply | 24 V AC at 50/60 Hz or 24 V DC |
|---|---|
| Permitted control-voltage factor | 0.85–1.1 times rated supply |
| Reset behavior | Automatic; no manual or external reset |
| Output contacts | 1 NO and 1 NC; AgSnO2 contact material |
| AC-15 contact rating | 3 A at 250 V AC |
| DC-13 contact rating | 1 A at 24 V; 0.2 A at 125 V; 0.1 A at 250 V |
| Maximum thermal contact current | 5 A |
| Rated-current power loss | 0.4 W for AC or DC operation |
| Maximum inrush | 1.8 A peak for 2 ms at 24 V |
| Supply interruption buffering | At least 40 ms |
| Typical mechanical life | 10 million cycles |
| Typical electrical life | 100,000 operations at AC-15, 24 V or 230 V |
| Insulation and impulse withstand | 300 V rated insulation; 4 kV impulse withstand |
| Terminal system | Removable spring-loaded push-in terminals |
| Conductor capacity | 0.5–4 mm² solid or unferruled stranded; 0.5–2.5 mm² ferruled stranded |
| Mounting | Any position; screw mounting or 35 mm DIN rail |
| Dimensions | 17.5 × 100 × 90 mm |
| Operating temperature | −25 to +60 °C |
| Maximum installation altitude | 2,000 m |
| Net weight | 102.46 g |
Frequently Asked Questions
Will 3RN2010-2CA30 reset automatically after a motor-temperature trip clears?
This version uses automatic reset rather than a manual reset action.
Can I connect a remote reset pushbutton to 3RN2010-2CA30?
The compact evaluation unit does not provide an external reset function.
Is 3RN2010-2CA30 suitable for a bimetallic temperature switch?
The evaluation unit is suitable for a bimetallic switch in the motor-temperature circuit.
Are the two outputs of 3RN2010-2CA30 one shared changeover contact?
The relay provides one normally open contact and one normally closed contact rather than one changeover contact.
Which local indications should I expect on 3RN2010-2CA30?
Two LEDs indicate the ready and tripped states.
Can 3RN2010-2CA30 run from either a 24 V AC or 24 V DC control source?
The rated control supply is 24 V AC at 50/60 Hz or 24 V DC.
Does 3RN2010-2CA30 retain a stored fault or dynamically detect an open sensor wire?
This version has neither error memory nor dynamic open-circuit detection.