Siemens 3RN2010-2CA30 SIRIUS 24 V AC/DC termistora elektrodzinēja aizsardzības relejs
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Select the automatic-reset version to match the intended motor-control restart sequence.
- Use a 24 V AC/DC control supply within the permitted voltage tolerance.
- Wire the separate NO and NC contacts according to their utilization-category ratings.
- Utege le terminales inseribili rimovibili con dimensioni dei conduttori appropriate per cablaggi con o senza guaine.
3RN2010-2CA30 SIRIUS 24 V AC/DC Thermistor Motor Protection Relay
A compact automatic-reset motor-protection relay with a 24 V AC/DC supply, one NO contact, one NC contact and removable push-in terminals.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 3RN2010-2CA30 |
| Typus Producti | Thermistor protection evaluation unit |
| Functio principalis | Motor-temperature protection evaluation |
| Applicatio | Thermistor and bimetallic-switch motor circuits |
Automatic thermal recovery
The automatic-reset version restores its evaluation state after the trip condition clears without a manual or external reset input.
Separate output contacts
Unus contactus normaliter apertus et unus contactus normaliter clausus praebent duas vias commutandi electricae separatas.
Indicatio status compacta
LEDs 'praestans' et 'excitatus' indicant localiter statum rellais in instrumento arcae 17,5 mm latae.
Product Overview
3RN2010-2CA30 aestimat circuitum sensoris temperaturae motoris et commutat contactus output separatim normaliter apertos et normaliter clausos.
Unitas compacta 17,5 mm utitur repositione automatica, praebet indicationes 'praestans' et 'excitatus', et idonea est tam pro commutatore temperaturae bimetallico quam pro applicatione protectionis thermistoris.
Key Functions
Automatic thermal recovery
The automatic-reset version restores its evaluation state after the trip condition clears without a manual or external reset input.
Separate output contacts
Unus contactus normaliter apertus et unus contactus normaliter clausus praebent duas vias commutandi electricae separatas.
Indicatio status compacta
LEDs 'praestans' et 'excitatus' indicant localiter statum rellais in instrumento arcae 17,5 mm latae.
Official Specifications
| Control Supply | 24 V AC a 50/60 Hz o 24 V DC |
|---|---|
| Factor tensionis controlis permissus | 0,85–1,1 vicibus tensionis nominalis |
| Comportamentum repositionis | Automaticum; nulla repositio manualis aut externa |
| Contactus Exirentes | 1 NO et 1 NC; materiale de contact AgSnO2 |
| Classis contactuum AC-15 | 3 A ad 250 V AC |
| DC-13 contactus valoris | 1 A ad 24 V; 0.2 A ad 125 V; 0.1 A ad 250 V |
| Maxima currentis thermicae per contactus | 5 A |
| Praestituta Potentia Amissa | 0.4 W pro operatione AC vel DC |
| Inrumpens Maximum | 1.8 A in vertice pro 2 ms ad 24 V |
| Custodia interruptionis suppetentiae | Minime 40 ms |
| Vita mecanica typica | 10 milia cyclorum |
| Vita electrica typica | 100 000 operationes ad AC-15, 24 V vel 230 V |
| Isolatio et resistentia ad impulsus | isolatio nominalis 300 V; resistentia ad impulsus 4 kV |
| Systema terminalis | Terminalia press-in cum molla removibilia |
| Capacitas conductoris | 0.5–4 mm² solidum vel non ferrulatum torquatum; 0.5–2.5 mm² torquatum ferrulatum |
| Montatio | Any position; screw mounting or 35 mm DIN rail |
| Dimensiones | 17.5 × 100 × 90 mm |
| Temperatura operativa | −25 usque ad +60 °C |
| Altitudo Installationis Maxima | 2,000 m |
| Ponderis netum | 102.46 g |
Quaestiones Frequenter Rogatae
Will 3RN2010-2CA30 reset automatically after a motor-temperature trip clears?
This version uses automatic reset rather than a manual reset action.
Can I connect a remote reset pushbutton to 3RN2010-2CA30?
The compact evaluation unit does not provide an external reset function.
Is 3RN2010-2CA30 suitable for a bimetallic temperature switch?
The evaluation unit is suitable for a bimetallic switch in the motor-temperature circuit.
Are the two outputs of 3RN2010-2CA30 one shared changeover contact?
The relay provides one normally open contact and one normally closed contact rather than one changeover contact.
Which local indications should I expect on 3RN2010-2CA30?
Duo LED statum parati et statum trip indicant.
Can 3RN2010-2CA30 run from either a 24 V AC or 24 V DC control source?
The rated control supply is 24 V AC at 50/60 Hz or 24 V DC.
Does 3RN2010-2CA30 retain a stored fault or dynamically detect an open sensor wire?
This version has neither error memory nor dynamic open-circuit detection.