Overview
SIRIUS 3RN2

3RN2010-1CA30 SIRIUS 3RN2 Thermistor Motor Protection Relay

A compact 17.5 mm evaluation relay with 24 V AC/DC supply, automatic reset and separate NO and NC contacts.

At a Glance

Brand Siemens
Model 3RN2010-1CA30
Product Type Motor temperature protection relay
Core Function Evaluating thermal sensor signals
Application Motor winding temperature supervision

Evaluate temperature sensors

The compact evaluation unit provides thermistor motor protection and is suitable for bimetallic switches.

Indicate the protection state

Two LEDs show ready and tripped conditions.

Integrate into the control circuit

One normally open contact and one normally closed contact provide relay outputs.

Product Overview

3RN2010-1CA30 evaluates motor-temperature sensing circuits in a compact SIRIUS 3RN2 housing.

The automatic-reset design is also suitable for a bimetallic switch and provides separate ready and tripped indications for local supervision.

Ordering focus: Use a 24 V AC/DC control supply and account for automatic reset in the motor control circuit.
Key Functions

Evaluate temperature sensors

The compact evaluation unit provides thermistor motor protection and is suitable for bimetallic switches.

Indicate the protection state

Two LEDs show ready and tripped conditions.

Integrate into the control circuit

One normally open contact and one normally closed contact provide relay outputs.

Official Specifications
Control Supply 24 V AC at 50/60 Hz or 24 V DC
Supply Operating Factor 0.85–1.10 times rated voltage
Reset Arrangement Automatic reset; no manual or external reset
Output Contacts 1 NO and 1 NC; AgSnO₂ contact material
AC-15 Contact Rating 3 A at 250 V AC
DC-13 Contact Ratings 1 A at 24 V DC; 0.2 A at 125 V DC; 0.1 A at 250 V DC
Maximum Thermal Contact Current 5 A
Typical Power Loss 0.4 W
Supply Buffering At least 40 ms
Rated Insulation Voltage 300 V, overvoltage category III and pollution degree 3
Impulse Withstand Voltage 4 kV
Mechanical Endurance 10 million operating cycles typical
Terminal Type Removable screw terminals
Conductor Cross-Section Single solid or ferruled finely stranded conductor: 0.5–4 mm²
Terminal Tightening Torque 0.6–0.8 N·m
Mounting Screw mounting or snap-on mounting on 35 mm DIN rail; any position
Operating Temperature −25 to +60 °C
Maximum Installation Altitude 2,000 m
Dimensions (W × H × D) 17.5 × 100 × 90 mm
Net Weight 104.46 g
Official source:Siemens product data sheet
Frequently Asked Questions

Will 3RN2010-1CA30 require a manual reset after a trip?

This compact evaluation unit uses automatic reset and has no manual-reset function.

Can a bimetallic temperature switch be evaluated by 3RN2010-1CA30?

The relay is suitable for use with a bimetallic switch as well as thermistor motor protection.

Can I supply 3RN2010-1CA30 directly from a 230 V AC control circuit?

The required control supply is 24 V AC or 24 V DC.

Can a remote reset pushbutton be connected to 3RN2010-1CA30?

An external-reset function is not provided on this automatic-reset version.

Which local indications help identify the state of 3RN2010-1CA30?

Two LEDs indicate the ready and tripped states.

How can 3RN2010-1CA30 provide both permissive and trip signals?

The output arrangement provides one normally open contact and one normally closed contact.

Can the control terminals be removed from 3RN2010-1CA30 for service?

The auxiliary and control circuits use removable screw terminals.

Compatibility & Ordering Notes
Before ordering 3RN2010-1CA30: Use a 24 V AC/DC control supply and account for automatic reset in the motor control circuit.

Before installation

  • Provide 24 V AC at 50/60 Hz or 24 V DC within the permitted supply range.
  • Design the control sequence for automatic reset rather than manual or remote reset.
  • Keep contact loads within the relevant AC-15 or DC-13 rating.
  • Tighten screw terminals to 0.6–0.8 N·m and use the specified conductor sizes.
Hot Selling Models
4138.942 SZ4138.942
UPA3 0432-102
UPA3 0432-103
FM-00
5SX23067
ERSDQB20-20D
RXZE1S111M
6ES7154-4AB10-0AB0
563491100040
3LD2704-0TK51
3LD2704-0TK53
D040009DWEG
MGN61326
VIOK1.5 2718015
JMDDH-5/2-D-1-C-SA

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.