Siemens 3RK1908-0AP00-0DP0 ET 200SP BU30-MS4 BaseUnit without Infeed
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Select BU30-MS4 for a position without a separate infeed.
- Match the existing power-group arrangement before inserting the starter.
- Keep load-outgoing conductors within 0.5–2.5 mm².
- Provide 50 mm ventilation space above and below and apply the appropriate current derating.
3RK1908-0AP00-0DP0 ET 200SP BU30-MS4 BaseUnit without Infeed
A BU30-MS4 BaseUnit without infeed, providing the wiring base for a starter position within an existing power group.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RK1908-0AP00-0DP0 |
| Product Type | Motor-starter BaseUnit |
| Core Function | Continues an existing starter power group |
| Application | ET 200SP motor-starter assemblies |
No-infeed group position
The MS4 variant provides a starter position without a new infeed connection.
Push-in load termination
Load-outgoing conductors connect through spring-loaded terminals sized for 0.5–2.5 mm² wiring.
DIN-rail starter support
The 30 mm-wide base mounts horizontally or vertically as part of the ET 200SP starter assembly.
Product Overview
3RK1908-0AP00-0DP0 provides the motor-starter BaseUnit variant without a separate infeed connection.
Its push-in load terminals and compact 30 mm mounting width support a starter position supplied through the existing group, rather than establishing a new main or control infeed at that position.
Key Functions
No-infeed group position
The MS4 variant provides a starter position without a new infeed connection.
Push-in load termination
Load-outgoing conductors connect through spring-loaded terminals sized for 0.5–2.5 mm² wiring.
DIN-rail starter support
The 30 mm-wide base mounts horizontally or vertically as part of the ET 200SP starter assembly.
Official Specifications
| Main-circuit poles | 3 poles, AC |
|---|---|
| Maximum operating voltage | 500 V AC |
| Rated operational current | 32 A at 400 V AC; installation-dependent derating applies |
| Control supply rating | 24 V DC; permitted 20.4–28.8 V DC |
| Maximum DC ampacity | 7 A |
| Insulation and impulse withstand | 500 V rated insulation; 6 kV impulse withstand |
| Pollution degree | 2 |
| Protective separation | Maximum 500 V between main and auxiliary circuits |
| Front protection | IP20; finger-safe |
| Terminal type | Spring-loaded push-in connections |
| Load-outgoing conductors | 0.5–2.5 mm²; AWG 20–12 |
| Operating temperature | −25 to +60 °C; derating applies |
| Storage and transport temperature | −40 to +70 °C |
| Required clearance | 50 mm above and below |
| Dimensions | 30 × 215 × 75 mm |
| Net weight | 0.16 kg |
| Shock withstand | 6 g for 11 ms |
| Release tool | Slotted screwdriver, 0.6 × 3.5 mm tip |
Frequently Asked Questions
Should I select 3RK1908-0AP00-0DP0 when a starter position needs a new infeed?
This BaseUnit is the version without infeed and belongs in a position supplied through the existing group.
How much can the existing 24 V control bus vary at 3RK1908-0AP00-0DP0?
The permitted DC control-supply range is 20.4–28.8 V.
Can 3RK1908-0AP00-0DP0 accept 4 mm² outgoing load conductors?
The load-outgoing terminals accept 0.5–2.5 mm² conductors, so 4 mm² is outside that range.
What release tool should I use for the terminals of 3RK1908-0AP00-0DP0?
Use a standard slotted screwdriver with a 0.6 × 3.5 mm tip.
How much rail width is required for 3RK1908-0AP00-0DP0?
The BaseUnit has a width of 30 mm.
Is the 32 A rating of 3RK1908-0AP00-0DP0 unconditional at high cabinet temperature?
The 32 A rating at 400 V AC is subject to the installation and temperature derating conditions.
Does 3RK1908-0AP00-0DP0 provide a station digital-input channel?
The BaseUnit has zero digital inputs.