Siemens 3RK1908-0AP00-0DP0 ET 200SP BU30-MS4 BaseUnit without Infeed

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200SP Motor Starters

3RK1908-0AP00-0DP0 ET 200SP BU30-MS4 BaseUnit without Infeed

A BU30-MS4 BaseUnit without infeed, providing the wiring base for a starter position within an existing power group.

At a Glance

Brand Siemens
Model 3RK1908-0AP00-0DP0
Product Type Motor-starter BaseUnit
Core Function Continues an existing starter power group
Application ET 200SP motor-starter assemblies

No-infeed group position

The MS4 variant provides a starter position without a new infeed connection.

Push-in load termination

Load-outgoing conductors connect through spring-loaded terminals sized for 0.5–2.5 mm² wiring.

DIN-rail starter support

The 30 mm-wide base mounts horizontally or vertically as part of the ET 200SP starter assembly.

Product Overview

3RK1908-0AP00-0DP0 provides the motor-starter BaseUnit variant without a separate infeed connection.

Its push-in load terminals and compact 30 mm mounting width support a starter position supplied through the existing group, rather than establishing a new main or control infeed at that position.

Ordering focus: Use the no-infeed BU30-MS4 variant within the intended power group and apply the starter’s installation-dependent voltage and current limits.
Key Functions

No-infeed group position

The MS4 variant provides a starter position without a new infeed connection.

Push-in load termination

Load-outgoing conductors connect through spring-loaded terminals sized for 0.5–2.5 mm² wiring.

DIN-rail starter support

The 30 mm-wide base mounts horizontally or vertically as part of the ET 200SP starter assembly.

Official Specifications
Main-circuit poles 3 poles, AC
Maximum operating voltage 500 V AC
Rated operational current 32 A at 400 V AC; installation-dependent derating applies
Control supply rating 24 V DC; permitted 20.4–28.8 V DC
Maximum DC ampacity 7 A
Insulation and impulse withstand 500 V rated insulation; 6 kV impulse withstand
Pollution degree 2
Protective separation Maximum 500 V between main and auxiliary circuits
Front protection IP20; finger-safe
Terminal type Spring-loaded push-in connections
Load-outgoing conductors 0.5–2.5 mm²; AWG 20–12
Operating temperature −25 to +60 °C; derating applies
Storage and transport temperature −40 to +70 °C
Required clearance 50 mm above and below
Dimensions 30 × 215 × 75 mm
Net weight 0.16 kg
Shock withstand 6 g for 11 ms
Release tool Slotted screwdriver, 0.6 × 3.5 mm tip
Official source:Siemens BU30-MS4 datasheet
Frequently Asked Questions

Should I select 3RK1908-0AP00-0DP0 when a starter position needs a new infeed?

This BaseUnit is the version without infeed and belongs in a position supplied through the existing group.

How much can the existing 24 V control bus vary at 3RK1908-0AP00-0DP0?

The permitted DC control-supply range is 20.4–28.8 V.

Can 3RK1908-0AP00-0DP0 accept 4 mm² outgoing load conductors?

The load-outgoing terminals accept 0.5–2.5 mm² conductors, so 4 mm² is outside that range.

What release tool should I use for the terminals of 3RK1908-0AP00-0DP0?

Use a standard slotted screwdriver with a 0.6 × 3.5 mm tip.

How much rail width is required for 3RK1908-0AP00-0DP0?

The BaseUnit has a width of 30 mm.

Is the 32 A rating of 3RK1908-0AP00-0DP0 unconditional at high cabinet temperature?

The 32 A rating at 400 V AC is subject to the installation and temperature derating conditions.

Does 3RK1908-0AP00-0DP0 provide a station digital-input channel?

The BaseUnit has zero digital inputs.

Compatibility & Ordering Notes
Before ordering 3RK1908-0AP00-0DP0: Use the no-infeed BU30-MS4 variant within the intended power group and apply the starter’s installation-dependent voltage and current limits.

Before installation

  • Select BU30-MS4 for a position without a separate infeed.
  • Match the existing power-group arrangement before inserting the starter.
  • Keep load-outgoing conductors within 0.5–2.5 mm².
  • Provide 50 mm ventilation space above and below and apply the appropriate current derating.
Hot Selling Models
7000-18141-0280500
efector200 OT5003
92/4-400S IRK92/4-400S
UB2000-30GM-E2-V15
6NH7701-4DL
AYE QET 4112
CPV10-EPL-PEU
6es5760-1aa11
VP342-5Y0D1-02FA
701160/8-0153-001-25
M30MI1-PSC22B-S04G
03/15/003 5VCT03J
18P1501
R2.067.0440.0
96M/P-1070-T2-21

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.