Overview
OMRON G700-U

G700-UMD16 SYSMAC BUS/2 Mixed Remote I/O Terminal

A 24 V DC mixed I/O terminal for SYSMAC BUS/2, combining positive-common inputs, NPN transistor outputs and selectable communications-error output behavior.

At a Glance

Brand Omron
Model G700-UMD16
Product Type Mixed remote I/O terminal
Core Function Exchanging field-input states and output commands
Application SYSMAC CV-series remote I/O with CV500-RM221

Mixed field connections

The terminal provides eight inputs and eight outputs with individual signal indicators.

Two-wire remote link

The communications connection uses B200-TW shielded twisted-pair cable.

HOLD or OFF response

The output-mode switch selects the response to a transmission error.

Product Overview

G700-UMD16 combines the remote-communications interface and field-wiring block in one G700-U terminal for a SYSMAC BUS/2 installation.

The input side uses a positive common and the transistor output side a negative common, while address, termination and output-mode switches establish the terminal’s role in the remote subsystem.

Ordering focus: Match the CV500-RM221 remote-master system, sensor polarity and transistor loads, then set the node address, final-node termination and required HOLD/OFF behavior before operation.
Key Functions

Exchange the remote field signals

The dedicated 1.5 Mbps link carries the field signals over a wired multi-drop connection with up to 500 m transmission distance.

Select the output response to a communication fault

HOLD retains the previous output state during a transmission error, while OFF clears the outputs.

Extend the field-wiring assembly

Compatible G700-T and G700-S blocks add I/O through their dedicated expansion cables within the selected slave-mode capacity.

Official Specifications
Native I/O Arrangement 8 positive-common inputs and 8 negative-common NPN outputs
Power Supply 24 V DC nominal; 21.6–26.4 V DC operating range
Maximum Internal Power Consumption 2.5 W, excluding I/O consumption
Communications Speed 1.5 Mbps
Transmission Method 1:N polling, Manchester coding and wired multi-drop topology
Maximum Transmission Distance 500 m
Maximum Transmission Delay 5.2 ms
Maximum Input Current 10 mA per point
Maximum Input Delays 1.5 ms for both ON and OFF transitions
Maximum Output Current 0.3 A per point
Maximum Output Residual Voltage 1.2 V
I/O Isolation Method Photocouplers
Bus-to-Supply Dielectric Test 1000 V AC at 50/60 Hz for 1 minute
Minimum Insulation Resistance 20 MΩ at 250 V DC
Ambient Temperature Operation: 0 to +55 °C; storage: −20 to +65 °C
Ambient Humidity 35–85%
Fuse Rating 3 A, 125 V
Approximate Weight 360 g
Frequently Asked Questions

Which remote master should I pair with G700-UMD16?

The G700-U remote subsystem connects to a CV500-RM221 Remote I/O Master Unit.

When should I set the node number on G700-UMD16?

Set its unique address from 00 to 31 before power-up or creation of the I/O table because later address changes are not recognized.

Where should I enable termination when using G700-UMD16?

Enable one terminator per remote master at the terminal farthest from that master.

How can I make G700-UMD16 clear its outputs after a transmission error?

Select OFF mode rather than HOLD mode on the output-mode switch.

Which replacement fuse rating applies to G700-UMD16?

The mixed I/O terminal uses a 3 A, 125 V fuse of the specified type.

What expansion blocks can connect to G700-UMD16?

Use the compatible G700-T or G700-S I/O blocks with their dedicated expansion cables and a supported slave-mode setting.

Can I use a three-wire NPN sensor with the inputs of G700-UMD16?

The positive-common input arrangement accepts the NPN sensor wiring shown for the terminal.

Compatibility & Ordering Notes
Before ordering G700-UMD16: Choose the mixed-input/output terminal for the SYSMAC BUS/2 subsystem, retaining the correct common polarity, node allocation, termination and expansion-block arrangement.

Compatibility Checklist for G700-UMD16

  • Connect to the supported CV500-RM221 remote-master arrangement using B200-TW cable.
  • Set a unique node address and the appropriate slave type before commissioning.
  • Enable the terminator only at the farthest terminal for the remote master.
  • Select HOLD or OFF to match the required response to a communications error.
  • Use positive-common input wiring and negative-common NPN output wiring.
  • Respect the output-current limit and use the specified fuse and expansion cables.
Hot Selling Models
A24/0.5-e
6ES5465-4UA12 6ES5498-1AA31
FAZ-3-B16
7000-12241-6351000
777-305
6GK1543-0AA01 6ES5377-0AA11
6ES7194-4AJ00-0AA0 6ES7154-4AB10-0AB0
LC1D09BD
3RT2026-1AL20 3RH2911-1HA22
DSNU-25-300-PPV-A
IN-3002LBPOG
ZDU10BL
VHK2/2-08F-08F
3RB2016-1RB0
3RT1316-2AP00

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.