- Connect to the supported CV500-RM221 remote-master arrangement using B200-TW cable.
- Set a unique node address and the appropriate slave type before commissioning.
- Enable the terminator only at the farthest terminal for the remote master.
- Select HOLD or OFF to match the required response to a communications error.
- Use positive-common input wiring and negative-common NPN output wiring.
- Respect the output-current limit and use the specified fuse and expansion cables.
G700-UMD16 SYSMAC BUS/2 Mixed Remote I/O Terminal
A 24 V DC mixed I/O terminal for SYSMAC BUS/2, combining positive-common inputs, NPN transistor outputs and selectable communications-error output behavior.
At a Glance
| Brand | Omron |
|---|---|
| Model | G700-UMD16 |
| Product Type | Mixed remote I/O terminal |
| Core Function | Exchanging field-input states and output commands |
| Application | SYSMAC CV-series remote I/O with CV500-RM221 |
Mixed field connections
The terminal provides eight inputs and eight outputs with individual signal indicators.
Two-wire remote link
The communications connection uses B200-TW shielded twisted-pair cable.
HOLD or OFF response
The output-mode switch selects the response to a transmission error.
Product Overview
G700-UMD16 combines the remote-communications interface and field-wiring block in one G700-U terminal for a SYSMAC BUS/2 installation.
The input side uses a positive common and the transistor output side a negative common, while address, termination and output-mode switches establish the terminal’s role in the remote subsystem.
Key Functions
Exchange the remote field signals
The dedicated 1.5 Mbps link carries the field signals over a wired multi-drop connection with up to 500 m transmission distance.
Select the output response to a communication fault
HOLD retains the previous output state during a transmission error, while OFF clears the outputs.
Extend the field-wiring assembly
Compatible G700-T and G700-S blocks add I/O through their dedicated expansion cables within the selected slave-mode capacity.
Official Specifications
| Native I/O Arrangement | 8 positive-common inputs and 8 negative-common NPN outputs |
|---|---|
| Power Supply | 24 V DC nominal; 21.6–26.4 V DC operating range |
| Maximum Internal Power Consumption | 2.5 W, excluding I/O consumption |
| Communications Speed | 1.5 Mbps |
| Transmission Method | 1:N polling, Manchester coding and wired multi-drop topology |
| Maximum Transmission Distance | 500 m |
| Maximum Transmission Delay | 5.2 ms |
| Maximum Input Current | 10 mA per point |
| Maximum Input Delays | 1.5 ms for both ON and OFF transitions |
| Maximum Output Current | 0.3 A per point |
| Maximum Output Residual Voltage | 1.2 V |
| I/O Isolation Method | Photocouplers |
| Bus-to-Supply Dielectric Test | 1000 V AC at 50/60 Hz for 1 minute |
| Minimum Insulation Resistance | 20 MΩ at 250 V DC |
| Ambient Temperature | Operation: 0 to +55 °C; storage: −20 to +65 °C |
| Ambient Humidity | 35–85% |
| Fuse Rating | 3 A, 125 V |
| Approximate Weight | 360 g |
Frequently Asked Questions
Which remote master should I pair with G700-UMD16?
The G700-U remote subsystem connects to a CV500-RM221 Remote I/O Master Unit.
When should I set the node number on G700-UMD16?
Set its unique address from 00 to 31 before power-up or creation of the I/O table because later address changes are not recognized.
Where should I enable termination when using G700-UMD16?
Enable one terminator per remote master at the terminal farthest from that master.
How can I make G700-UMD16 clear its outputs after a transmission error?
Select OFF mode rather than HOLD mode on the output-mode switch.
Which replacement fuse rating applies to G700-UMD16?
The mixed I/O terminal uses a 3 A, 125 V fuse of the specified type.
What expansion blocks can connect to G700-UMD16?
Use the compatible G700-T or G700-S I/O blocks with their dedicated expansion cables and a supported slave-mode setting.
Can I use a three-wire NPN sensor with the inputs of G700-UMD16?
The positive-common input arrangement accepts the NPN sensor wiring shown for the terminal.