Conspectus
- Connect to the supported CV500-RM221 remote-master arrangement using B200-TW cable.
- Set a unique node address and the appropriate slave type before commissioning.
- Enable the terminator only at the farthest terminal for the remote master.
- Select HOLD or OFF to match the required response to a communications error.
- Use positive-common input wiring and negative-common NPN output wiring.
- Respect the output-current limit and use the specified fuse and expansion cables.
G700-UMD16 Terminalis I/O remota mixta SYSMAC BUS/2
Terminalis I/O mixta 24 V DC pro SYSMAC BUS/2, combinans intradas communes positivas, extradas transistorum NPN et comportamentum selectabilem pro erroribus communicationis.
Ad Primum Aspectum
| Nota | OMRON |
|---|---|
| Modellum | G700-UMD16 |
| Typus Producti | Terminalis I/O remota mixta |
| Functio principalis | Exchanging status intradarum campi et mandatorum extradarum |
| Applicatio | I/O remota seriei SYSMAC CV cum CV500-RM221 |
Connexiones campi mixtae
Terminalis praebet octo intradas et octo extradas cum indicibus signalis individualibus.
Duo-filum remotum coniunctionem
Coniunctio communicationis utitur B200-TW scutatum contortum parvum cuniculum.
RESPONSIO HOLD vel OFF
Interruptor modi exsitus eligit responsionem ad errorem transmissionis.
Product Overview
G700-UMD16 combinat interfaciem remotam communicationis et impeditum connexionis in uno terminali G700-U pro installatione SYSMAC BUS/2.
Latus introituum utitur communi positivo et latus exsitus transistoris communi negativo, dum interruptores adressionis, terminationis et modi exsitus constituunt partem terminalis in sub-systema remotum.
Key Functions
Commutate signa remota campi
Link dedicatus 1.5 Mbps portat signa campi per connexionem filarem multi-drop cum distantia transmissionis usque ad 500 m.
Eligite responsionem exsitus ad defectum communicationis
HOLD retinet statum outputus praecedentem dum error transmittendi accidit, dum OFF effundit outputs.
Extendere coniunctionem conductorum in campo
Blocs G700-T et G700-S compatibiles addunt I/O per suos cables expansionis dedicatos intra capacitatem modi servili selectam.
Official Specifications
| Dispositio I/O nativa | 8 inputs communes positivi et 8 outputs NPN communes negativi |
|---|---|
| Fons Potentiae | 24 V DC nominalis; intervallo operativo 21.6–26.4 V DC |
| Consumptus internus potestatis maximus | 2.5 W, non includens consumptum I/O |
| Velocitas communicationis | 1,5 Mbps |
| Modus transmissionis | interrogatio 1:N, codificatio Manchester et topologia multi-drop filari |
| Maxima Distantia Transmissionis | 500 m |
| Maxima Delatio Transmissionis | 5.2 ms |
| Maximus Correntis Ingressus | 10 mA per punctum |
| Maximi Retardationes Input | 1.5 ms pro utrisque transitionibus ON et OFF |
| Currentia maxima emissa | 0.3 A per punctum |
| Maxima Tensio Residualis Output | 1,2 V |
| Methodus Isolationis I/O | Photocoupleres |
| Testis Dielectricus Bus-ad-Supplium | 1000 V AC ad 50/60 Hz per 1 minutum |
| Minima resistentia isolationis | 20 MΩ ad 250 V DC |
| Ambiens Temperature | Operation: 0 usque ad +55 °C; conservatio: −20 usque ad +65 °C |
| Ambientis Humiditas | 35–85% |
| Valor fusibilis | 3 A, 125 V |
| Pondus Approximatum | 360 g |
Quaestiones Frequenter Rogatae
Quem magistrum remotum cum G700-UMD16 coniungere debeam?
Subsystema remotum G700-U connectitur ad unitatem magistram CV500-RM221 Remote I/O.
Quando numerum nodi in G700-UMD16 constituere debeam?
Constitue suum unicum indicem ab 00 usque ad 31 ante initiationem electricam vel creationem tabellae I/O, quia mutationes posteriores indicis non agnoscuntur.
Ubi terminationem activare debeam, dum G700-UMD16 utitur?
Activare unum terminatorum pro singulo magistro remoto in terminali longissimo ab illo magistro.
Quomodo possum facere ut G700-UMD16 evacuet suos outputs post errorem transmissionis?
Elige modum OFF potius quam modum HOLD in commutatore modi output.
Quae valoris fusibilis substitutio ad G700-UMD16 pertinet?
Terminus mixtus I/O usus est fusibili 3 A, 125 V typi specificati.
Quae blocchi expansionis ad G700-UMD16 connecti possunt?
Utere compatibilibus blocis I/O G700-T vel G700-S cum eorum specialibus cavis expansionis et cum apta positione modi servilis.
Num possum sensorem NPN tri-filarem cum inputibus G700-UMD16 uti?
Dispositio input positivo-communis admittit connexiones sensoris NPN quae pro termino ostenduntur.