Leuze 96BM/C6-2000-S12 ODSL 96B Optical Distance Sensor
Manufacturer: Leuze
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use the C6 current-output configuration and a compatible 4–20 mA PLC input.
- Keep the analog-output load at or below 500 Ω.
- Keep the target within 150–2000 mm and account for reflectivity and object size in the measuring setup.
- Use the permitted M12 connection and maintain the required installation protection.
96BM/C6-2000-S12 ODSL 96B Optical Distance Sensor
A red-laser distance sensor with a 150–2000 mm measuring range, 4–20 mA output, push-pull switching output and local OLED configuration.
At a Glance
| Brand | Leuze |
|---|---|
| Model | 96BM/C6-2000-S12 |
| Product Type | Optical distance sensor |
| Core Function | Non-contact object-distance measurement |
| Application | Industrial object positioning and measurement |
Analog distance feedback
The C6 variant provides a 4–20 mA current output for a load resistance of up to 500 Ω.
Teachable object switching
A push-pull output provides a switching signal, and the switching and analog outputs can be taught for the application.
Local measurement setup
The OLED display shows distance in millimeters, while the keypad and PC software provide configuration access.
Product Overview
96BM/C6-2000-S12 is the current-output ODSL 96B distance-sensor configuration identified by Leuze article number 50106593.
It measures directly against an object and provides an analog distance signal alongside a teachable switching output, with measurement values and configuration available through the OLED display and keypad.
Key Functions
Analog distance feedback
The C6 variant provides a 4–20 mA current output for a load resistance of up to 500 Ω.
Teachable object switching
A push-pull output provides a switching signal, and the switching and analog outputs can be taught for the application.
Local measurement setup
The OLED display shows distance in millimeters, while the keypad and PC software provide configuration access.
Official Specifications
| Measurement range | 150–2000 mm |
|---|---|
| Resolution | 1–3 mm, depending on distance |
| Absolute measurement accuracy | ±1.5% of distance at 20 °C, midrange supply, 6–90% remission and target size ≥50 × 50 mm |
| Repeatability | ±0.5% of distance for the same object under identical conditions |
| Black/white deviation | At most 1% for 6–90% remission |
| Light source | Visible red laser, 655 nm, laser class 2 |
| Light spot | 2 × 6 mm at 2 m |
| Measurement time | 1–5 ms, dependent on target reflectivity and measurement mode |
| Response and startup time | Response at most 15 ms; startup delay at most 300 ms |
| Supply voltage | 18–30 V DC, including residual ripple |
| Permitted residual ripple | At most 15% of supply voltage |
| Bias current | At most 150 mA |
| Analog output | 4–20 mA; maximum load resistance 500 Ω |
| Switching output | Push-pull; high at least UB − 2 V, low at most 2 V |
| Programmable input | 1 digital switching input |
| Connection | M12, 5-pin male, A-coded |
| Housing and optics | Diecast-zinc housing; glass optical cover |
| Dimensions and weight | 30 × 90 × 70 mm; 380 g |
| Operating and storage temperatures | Operation −20 to +50 °C; storage −30 to +70 °C |
| Protection | IP67/IP69K; electrical protection class II |
Frequently Asked Questions
Can 96BM/C6-2000-S12 measure a target at 100 mm?
The specified measuring range starts at 150 mm and extends to 2000 mm.
Should I configure a PLC voltage input or current input for 96BM/C6-2000-S12?
Use a current input for the sensor’s 4–20 mA analog output.
What input-load resistance can I connect to the current output of 96BM/C6-2000-S12?
The total analog-output load resistance must not exceed 500 Ω.
Do I need a PC for every adjustment to 96BM/C6-2000-S12?
The sensor provides an OLED display and keypad for local configuration as well as PC software access.
Why can the measuring time of 96BM/C6-2000-S12 vary?
The measuring time depends on target reflectivity and the selected measurement mode.
Can I connect the push-pull outputs of multiple 96BM/C6-2000-S12 sensors in parallel?
The push-pull switching outputs must not be connected in parallel.
Which connector should I prepare for 96BM/C6-2000-S12?
Use a mating connector for the A-coded, five-pin M12 male connection.