Leuze 96BM/C6-2000-S12 ODSL 96B Optical Distance Sensor

Fabricator: Leuze
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
Leuze ODSL 96B

96BM/C6-2000-S12 ODSL 96B Optical Distance Sensor

A red-laser distance sensor with a 150–2000 mm measuring range, 4–20 mA output, push-pull switching output and local OLED configuration.

Ad Primum Aspectum

Nota Leuze
Modellum 96BM/C6-2000-S12
Typus Producti Optical distance sensor
Functio principalis Non-contact object-distance measurement
Applicatio Industrial object positioning and measurement

Analog distance feedback

The C6 variant provides a 4–20 mA current output for a load resistance of up to 500 Ω.

Teachable object switching

Outputus push-pull praebet signum commutativum, et outputus commutativus et analogus doceri possunt pro applicatione.

Constitutio localis mensurae

Display OLED distentiam in millimetris ostendit, dum clavium et software PC aditus ad constitutionem praebent.

Product Overview

96BM/C6-2000-S12 est configuratio sensoris distantiae ODSL 96B cum outputus currentis, quae numerum articuli Leuze 50106593 identificat.

Directe contra obiectum metitur et signum analogum distantiae praebet una cum outputu commutativo docibili; valores mensurae et constitutio per display OLED et clavium adhiberi possunt.

Focus ordinandi: Adaptare interfaciem currentis 4–20 mA, distantiam destinatam, connexionem M12 et resistentiam oneris inputus analogici PLC.
Key Functions

Analog distance feedback

The C6 variant provides a 4–20 mA current output for a load resistance of up to 500 Ω.

Teachable object switching

Outputus push-pull praebet signum commutativum, et outputus commutativus et analogus doceri possunt pro applicatione.

Constitutio localis mensurae

Display OLED distentiam in millimetris ostendit, dum clavium et software PC aditus ad constitutionem praebent.

Official Specifications
Mensura Range 150–2000 mm
Resolutio 1–3 mm, secundum distantiam
Accuratio absoluta mensurae ±1.5% distantiae ad 20 °C, in medio intervallo supplitus, remissione 6–90% et magnitudine obiecti ≥50 × 50 mm
Repeatability ±0.5% distantiae pro eodem obiecto sub eisdem condicionibus
Deviatio nigra/alba Maxime 1% pro remissione 6–90%
Fons Lucis Laser ruber visibilis, 655 nm, classis laser 2
Macula lucis 2 × 6 mm ad 2 m
Tempus mensurationis 1–5 ms, secundum reflectivitatem obiecti et modum mensurationis
Tempus responsionis et initiationis Tempus responsionis maxime 15 ms; tempus morae initiationis maxime 300 ms
Supple voltage 18–30 V CC, incluse undulationes residuales
Undulationes residuales permissae Maxime 15% de voltatio supply
Currentia Bias Maxime 150 mA
Analogus Exitus 4–20 mA; resistentia maxima de onus 500 Ω
Commutatio exitus Push-pull; altum minime UB − 2 V, bassum maxime 2 V
Ingressus programmabilis 1 ingressus digitalis commutans
Nexus M12, masculinum 5-pin, codicatus A
Corpus et optica Corpus ex zinc die-cast; tectum opticum ex vitro
Dimensiones et Pondera 30 × 90 × 70 mm; 380 g
Temperatura operativa et temperatus depositi Operation −20 ad +50 °C; depositum −30 ad +70 °C
Protection IP67/IP69K; classis protectionis electricae II
Quaestiones Frequenter Rogatae

Num 96BM/C6-2000-S12 potest mensurare obiectum ad distantiam 100 mm?

Intervalum mensurationis specificatum incipit ab 150 mm et extenditur usque ad 2000 mm.

Num oportet me configurare ingressum tensionis PLC an ingressum currentis pro 96BM/C6-2000-S12?

Utere ingressum currentis pro analogica emissione sensoris 4–20 mA.

Quam resistentiam oneris ingressus possum coniungere ad emissionem currentis 96BM/C6-2000-S12?

Resistentia totalis oneris emissionis analogicae non debet superare 500 Ω.

Do I need a PC for every adjustment to 96BM/C6-2000-S12?

The sensor provides an OLED display and keypad for local configuration as well as PC software access.

Why can the measuring time of 96BM/C6-2000-S12 vary?

The measuring time depends on target reflectivity and the selected measurement mode.

Can I connect the push-pull outputs of multiple 96BM/C6-2000-S12 sensors in parallel?

The push-pull switching outputs must not be connected in parallel.

Which connector should I prepare for 96BM/C6-2000-S12?

Use a mating connector for the A-coded, five-pin M12 male connection.

Compatibility & Ordering Notes
Before ordering 96BM/C6-2000-S12: Adaptare interfaciem currentis 4–20 mA, distantiam destinatam, connexionem M12 et resistentiam oneris inputus analogici PLC.

Antequam Installatio

  • Use the C6 current-output configuration and a compatible 4–20 mA PLC input.
  • Tenere il carico di uscita analogica a 500 Ω o inferiore.
  • Tenere l’obiettivo entro 150–2000 mm e tenere conto della riflettività e delle dimensioni dell’oggetto nell’impostazione di misurazione.
  • Usare il collegamento M12 consentito e mantenere la protezione di installazione richiesta.
Hot Selling Models
RL90-18/24
FAZ-K25/3 278913 + FAZ-XHIN11
769-105 51128256
4BU3031092
Allen-Bradley 700-CF220Z
Allen-Bradley 700-CF400Z
3RV1341-4JC10
5SY5125-7
ADN-12-90-APA
DSNU-16-170-PPV
LC1D40A LAD4T3B
50/30(30) 600/5A 5VA Cl.0.5 FS5
535.6101.0
3RV2411-1FA20 3RV2901-2E
C10A10X

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.