ABB 1SAM201902R1001 HK1-11 Dextra 1 NO + 1 NC Contactus Auxiliaris
Fabricator: ABB
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Match the MS116 or MS132 starter attachment.
- Use an appropriate trip-signaling accessory if a trip-only signal is required.
- Strip auxiliary conductors to 8 mm.
- Apply the 0.8–1.2 N·m terminal torque.
1SAM201902R1001 HK1-11 Dextra Pars: 1 NO + 1 NC Contactus Auxiliaris
Blocus auxiliaris ABB HK1-11 montatus in latere, cum uno contactu normaliter aperto et uno normaliter clauso, ad significationem status et ad connexionem regulandam initiatoris motoris.
Ad Primum Aspectum
| Nota | ABB |
|---|---|
| Modellum | 1SAM201902R1001 |
| Typus Producti | Accessorium contactus auxiliaris |
| Functio principalis | Secundum statum principalium contactuum initiatoris motoris |
| Applicatio | Manuales initiatores motoris ABB MS116 et MS132 |
Installatio in parte dextra
Blocus auxiliaris montatur in parte dextra initiatoris motoris manualis compatibilis.
Main-contact following
The auxiliary contacts change position together with the starter main contacts.
Voltage-specific duties
AC-15 and DC-13 operating-current ratings differ by control voltage.
Product Overview
1SAM201902R1001 extends a compatible ABB manual motor starter with an HK1-11 auxiliary contact arrangement.
One normally open and one normally closed path follow the main-contact state for interlocking or indication circuits, while screw terminals provide the field-wire connections.
Key Functions
Follow starter operation
The auxiliary contacts change position with the main contacts of the manual motor starter.
Provide complementary control paths
Unus contactus normaliter apertus et unus contactus normaliter clausus adiuvant signa status necessaria schematis de controllo.
Finire le circuito ausiliario
Coniunctiones per vitam M3 utuntur praeparatione conductoris specificata et momento torsionis adstringendi.
Official Specifications
| Disposizione dei contatti | 1 NA + 1 NC |
|---|---|
| Tension assignée de service | 690 V AC aut 600 V DC |
| Currentus thermalis conventionalis in aere libero | 6 A |
| Frequentia censita | 50/60 HZ |
| Tensione impulsiva subita evaluata | 6 kV |
| Tensionis insulatio evaluata | 690 V AC |
| Gradus Contaminations | 3 |
| Operans ambientium temperatus | −25 ad +70 °C |
| Temperatura ambientalis servandae | −50 ad +80 °C |
| Resistentia ad ictum | 25 g pro 11 ms, IEC 60068-2-27 |
| Tempus operis | 100% |
| Durabilitas Mechanica et Electrica | 50 000 cycli singuli |
| Capacitas coniunctionis conductoris rigidi | 1 aut 2 × 1–1,5 mm² |
| Capacitas coniunctionis conductoris flexibilis | 1 aut 2 × 0.75–1.5 mm², cum aut sine ferrulis |
| Longitudo Exscindendae Partis Filii | 8 mm |
| Par de torsion pro terminalibus | 0,8–1,2 N·m |
| Vitus terminalis et instrumentum | M3; Pozidriv 2 |
| AC-15 currentes operativi | 6 A ad 24/120 V; 4 A ad 240 V; 3 A ad 400 V; 1 A ad 440/690 V |
| DC-13 currentes operativi | 2 A ad 24 V; 0.55 A ad 125 V; 0.27 A ad 250 V; 0.15 A ad 440/600 V |
| Conditiones minimae commutandae | 17 V et 5 mA |
Quaestiones Frequenter Rogatae
Num 1SAM201902R1001 indicat solummodo trip fault motoris incipientis?
Non, contactus auxiliarii HK1 sequuntur contactus principales starteris potius quam signum trip-only dedicatum praebent.
Quae pars starteris motoris manualis 1SAM201902R1001 accipit?
Blox auxiliare lateriter in parte dextra montatur.
Potestne 1SAM201902R1001 viam controllem tam apertam quam clausam praebere?
Ita, blox unum contactum normaliter apertum et unum normaliter clausum habet.
Quantam insulationem ab conductoribus pro 1SAM201902R1001 removere debeo?
Singulos conductores ad longitudinem specificatam 8 mm exspoliare debes.
Quod instrumentum et quod momentum ad usum in vitiis terminalibus 1SAM201902R1001 utendum est?
Instrumentum Pozidriv 2 in terminalibus M3 utere et ad momentum 0,8–1,2 N·m constringe.
Potestne 1SAM201902R1001 onerem controllem AC-15 5 A ad 240 V commutare?
No, the AC-15 operating-current rating at 240 V is 4 A.
Is 1SAM201902R1001 suitable for a very low-level 5 V signal circuit?
No, the specified minimum switching conditions are 17 V and 5 mA.