Overview

Place of Origin:

USA

Brand Name:

GE

Model Number:

IC695ALG626

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Specification

Module Name

IC695ALG626

Module Type

Analog Input Module

Dimensions

3.5 × 13.5 × 13.5 cm

Weight

0.24 kg

Input Ranges

Current: 0–20 mA, 4–20 mA, ±20 mAVoltage: ±10 V, 0–10 V, ±5 V, 0–5 V, 1–5 V

Backplane Power

600 mA max @ 5 VDC (+5% / -2.5%)625 mA max @ 3.3 VDC (+5% / -3%)

Power Dissipation

7.35 W max

Resolution

24-bit ADC, converted to floating point or integer

Input Data Format

Configurable: 32-bit IEEE floating point or 16-bit integer in 32-bit field

Filter Options

8 Hz, 12 Hz, 16 Hz, 40 Hz, 200 Hz, 500 Hz

Input Impedance

>100 kΩ (voltage inputs), 249 Ω ±1% (current inputs)

Open Circuit Detection

1 s max

Overvoltage / Overcurrent

±60 VDC, ±28 mA continuous max

Common Mode Noise Rejection

120 dB min @ 50/60 Hz (8 Hz filter)110 dB min @ 50/60 Hz (12 Hz filter)

Channel-to-Channel Crosstalk

-80 dB min (single-ended)-80 dB min (differential, grounded)-60 dB min (differential, floating)

Calibrated Accuracy (13–33°C)

±5 V, ±10 V, ±20 mA: 0.05% of range0–10 V, 0–5 V, 1–5 V, 0–20 mA: 0.1%4–20 mA: 0.125%

Calibrated Accuracy (0–60°C)

0–10 V, 0–5 V, 1–5 V: 0.2%0–20 mA: 0.25%4–20 mA: 0.3125%±5 V, ±10 V: 0.1%±20 mA: 0.125%

Calibration Interval

12 months typical

Isolation Voltage

Terminal block to backplane/chassis: 250 VAC continuous, 1500 VAC for 1 min (opto-isolated, transformer isolated)

Programmer Support

Machine Edition version 5.5 and later

Description

The IC695ALG626 is a Highway Addressable Remote Transducer (HART) 5.0 capable analog input module from the PACSystem RX3i platform. This module is previously manufactured by GE Intelligent Platform (GE IP) which was recently acquired by Automation. This module is mainly used to interface with analog field instruments that measures process variables and transmit the measurement to the receiving element such as the IC695ALG626 for processing. With this, the IC695ALG626 may be used with field instruments that provide 0 to 20mA, 4 to 20mA, ± 20mA current signals and ±10V, 0 to 10V, ±5V, 0 to 5V, 1 to 5V voltage signals. The IC695ALG626 is capable of providing Sixteen (16) input channels if configured for single-ended inputs and Eight (8) inputs for differential wiring. With support for HART protocol, each channel can be communicated with an external HART communicator to access not only the reading but other HART parameters as well. The IC695ALG626 comes with LED status indicator such as Module OK, Field Status and TB LED. The Module OK LED is used to indicates a properly configured module when LED is lit solid Green; with error if slowly blinking Green or Amber; Module not properly configured when blinking rapidly; defective or no power present when the module LED is Off. The Field status LED is lit solid Green indicating no fault on enabled channels and when terminal block is present; Yellow light depicts a channel of the module is in faulted state and an Off LED depicts a disconnected or improperly installed terminal block. The TB LED is lit Red when the terminal block is not connected; Lit Green when the terminal block is connected and Off if no backplane power is present.

Applications

Fine chemical and oil refinery: Monitors reactor temperature, pipeline pressure, and flow rate. Analysis: High-precision data acquisition ensures accurate chemical reaction ratios.

Large thermal/hydropower plants: Monitors oil pressure, bearing temperature, and water level. Analysis: Multi-channel design suitable for dense sensor access in large generator sets.

Food and beverage processing plants: Controls filling liquid level and sterilization temperature. Analysis: The Rx3i platform supports hot-swapping, ensuring uninterrupted maintenance of the production line.

Features

Completely software-configurable, no module jumpers to set

▪ Full autocalibration

▪ On-board error-checking

▪ Open-circuit detection for all voltage and 4-20mA inputs

▪ Configurable scaling and offsets per channel

▪ High alarm, low alarm, high-high alarm, low-low alarm detection

and reporting selectable per channel

▪ Module fault reporting

▪ Supports diagnostic point fault contacts in the logic program

▪ Flash memory for future upgrades

▪ Positive and negative Rate of Change Alarms

▪ Autocalibration at startup

▪ Configurable interrupts for channel alarms and faults

▪ Terminal Block insertion or removal detection

▪ Version 5.0 HART communications

Installation

Installation in Hazardous Areas:

Equipment labeled with reference to Class I, Groups A, B, C & D, Div. 2 hazardous areas is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous areas only.

Warning – Explosion hazard – Substitution of components may impair suitability for Class I, Division 2.

Warning – Explosion hazard – When in hazardous areas, turn off power before replacing or wiring modules.

Warning – Explosion hazard – Do not connect or disconnect equipment unless power has been switched off or the area is known to be nonhazardous.

FAQ

Q: What is an IC695ALG626?
A: The IC695ALG626 is a 16/8 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input module from the GE Fanuc RX3i Series.

Q: What does IC695ALG626 provide?
A: This module provides 16 single-ended or 8 differential input channels.

Q: What does IC695ALG626 feature?
A: This module features HART version 5.0 communications capability on each channel.

Q: How many HART modems does IC695ALG626 have?
A: This module has 4 internal HART modems.

Q: What happens in single-ended mode?
A: In single-ended mode, 4 single-ended channels are multiplexed into each HART modem.

Q: What happens in differential mode?
A: In differential mode, 2 differential channels are multiplexed into each HART modem.

Q: For configuration, at what ranges can the analog input channels be set?
A: Current: 0 to 20 mA, 4 to 20 mA, ±20 mA. Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V.

Q: For channels that use HART communications, what must the configuration be?
A: It must be in the 4-20 mA range.