Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6dl1193 6ga00 0nn0 simatic et 200sp ha two position carrier module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA Two-Position Carrier Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC ET 200SP HA

6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA Two-Position Carrier Module

A two-position ET 200SP HA carrier for building the modular I/O assembly, with asset I&M data, potential-group support and a 45 mm installed width.

At a Glance

Brand Siemens
Model 6DL1193-6GA00-0NN0
Product Type I/O carrier module
Core Function Providing mechanical support and backplane continuity
Application ET 200SP HA terminal-block and I/O assemblies

Modular I/O support

The carrier combines with the terminal blocks to create the I/O slots.

Installed width

The installed carrier width is 45 mm; the loose component is 52.5 mm wide.

Station assembly

Carrier modules are connected in order before the terminal blocks are fitted.

Product Overview

6DL1193-6GA00-0NN0 forms the two-position carrier portion of an ET 200SP HA I/O assembly, providing the mechanical and electrical connection used with the selected terminal blocks.

The carrier supports potential groups and asset I&M data, with separate insulation test values for the backplane, supply groups and functional-ground interfaces.

Ordering focus: Choose the I/O carrier rather than the interface-module carrier, plan the terminal-block widths, and assemble and align the carrier chain before installing the terminal blocks.
Key Functions

Build the I/O positions with the terminal blocks

The carrier and the selected terminal blocks together create the mechanical and electrical slots for the I/O modules.

Continue the carrier and backplane assembly

The carrier is joined to the component on its left using the interlocks before its fixing screws secure it to the rail.

Provide asset and isolation features

Asset I&M data and the specified electrical-separation interfaces support the completed HA station assembly.

Official Specifications
Number of I/O Positions 2
Identification and Maintenance Data Asset I&M data supported
Backplane-to-Supply Isolation Test 4200 V DC for 1 minute, type test
Supply-Group Separation Test 3510 V AC for 5 seconds, type test
Backplane-to-Functional-Ground Test 1500 V DC for 1 minute, type test
Horizontal Operating Temperature −40 to +70 °C
Vertical Operating Temperature −40 to +60 °C
Dimensions and Installed Width 52.5 × 203 × 79 mm; width when installed 45 mm
Approximate Weight 111 g
Frequently Asked Questions

Is 6DL1193-6GA00-0NN0 the carrier for the station interface module?

This article is the carrier for I/O positions rather than the separate carrier used for interface modules.

Should I fit terminal blocks before joining 6DL1193-6GA00-0NN0 to the carrier chain?

Install the carrier modules one after another before starting terminal-block installation.

Why does the loose width of 6DL1193-6GA00-0NN0 differ from the installed width?

The component is 52.5 mm wide before assembly and occupies 45 mm when installed.

Can I create complete I/O slots using 6DL1193-6GA00-0NN0 without terminal blocks?

The I/O slots are created by combining the carrier module with the selected terminal blocks.

How should I align 6DL1193-6GA00-0NN0 with the neighboring carriers before tightening it?

Latch several carriers onto the rail and join them with the interlocks before tightening the fixing screws.

Can I use 6DL1193-6GA00-0NN0 vertically at 70 °C?

The vertical operating limit is +60 °C, while horizontal installation permits up to +70 °C.

Does 6DL1193-6GA00-0NN0 support identification data for asset records?

The carrier supports asset identification and maintenance data.

Compatibility & Ordering Notes
Before ordering 6DL1193-6GA00-0NN0: Select the two-position I/O carrier for the planned terminal-block layout, retaining the separate interface carrier and the correct installed width and mounting-temperature limit.

Compatibility Checklist for 6DL1193-6GA00-0NN0

  • Use this carrier for I/O positions in an ET 200SP HA station.
  • Match the terminal-block widths and required I/O positions to the carrier layout.
  • Install and interlock the carrier chain before fitting the terminal blocks.
  • Remove the transport lock and align the carriers before tightening the fixing screws.
  • Plan 45 mm installed width and the stated height and depth.
  • Apply the +70 °C horizontal or +60 °C vertical upper operating limit.
Hot Selling Models
RJ1A60D30EV
6ES7193-7DA10-0AA0
U8626-5
GV2ME08 034309
PLC-RPT-24DC/21-21
1824 484 026
1SAM401906R1002
DFSP-20-20-DS-PA
5SG7733
6MT31
PCD4.A81 PCD4.A810
R5024 7463110H
3RV2021-0GA10
PKE12XTPE012B XTPEXT1P2B
9512 000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.