Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
ci615 3bht300024r1bus coupler unit-0

For ABB

Home >  Products >  For ABB

CI615 3BHT300024R1 Bus Coupler Unit

  • Overview
  • Specifications
  • Description
  • Applications
  • Competitive Advantage
  • Troubleshooting and Maintenance
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

CI615 3BHT300024R1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Product Details

Model

CI615 3BHT300024R1

Device Type

Bus Coupler Unit

Net Dimensions

3.9 x 25.1 x 27.3 cm

Net Weight

1.16 kg

RoHS Status

Exempted from the scope of 2011/65/EU (Article 2(4)(c),(e),(f))

WEEE Category

5. Small Equipment (No External Dimension More Than 50 cm)

Number of Batteries

C

Application

I/O Extension Unit

Operating Temperature

-20 °C to +70 °C

Storage Temperature

-40 °C to +85 °C

Operating Voltage Range

12–48 V DC

Communication Protocol

DeviceNet

Data Transfer Rate

500 Kbps

Number of Channels

16

Description

The ABB CI615 3BHT300024R1 I/O Bus Coupler enables fast and reliable data exchange across distributed control systems. Designed for the AC500 series, this module supports seamless integration and real-time process control. Its robust 3.9 x 25.1 x 27.3 cm housing and 1.16 kg weight ensure stable performance in industrial environments.

Applications

Thermal power plants: High-speed communication between the main DDC system and remote I/O.

Large chemical plants: Distributed control outside flammable and explosive areas.

Steel and iron metallurgical plants: Remote signal transmission for production lines in harsh environments.

Cement processing plants: Distributed equipment management across workshops.

Water treatment plants: Centralized control of decentralized pumping stations.

Competitive Advantage

Enable high-speed communication between I/O modules and control processors.

Support real-time diagnostics for preventive maintenance and system health tracking.

Integrate easily into ABB AC500 DCS platforms with minimal configuration.

Maintain stable operation in power generation, oil and gas, and manufacturing sectors.

Reduce downtime with fast data processing and robust system design.

Simplify installation using modular architecture and flexible mounting options.

Troubleshooting and Maintenance

Troubleshooting:

Cable Fault Alarm: The CI615 has a cable detection function. If an error occurs, please focus on checking the shielding and termination of the TK612 or TK610 bus cables.

Address Configuration Error: Check the address switch under the top cover of the module to ensure it matches the software configuration.

Redundancy Synchronization Failure: In a redundant configuration, if the master/slave switchover is abnormal, check the synchronization link.

Maintenance Recommendations:

Heat Sink Maintenance: The module uses an aluminum cast chassis as a heat sink. Ensure good air circulation in the installation environment to prevent heat buildup.

Regular Backup: Perform annual backups of the Advant Controller configuration to prevent data loss in case of hardware failure.

FAQ

Q: What is the CI615 3BHT300024R1?
A: The CI615 3BHT300024R1 is a Bus Coupler Unit used to connect the controller (master station) with the I/O network.

Q: What is the difference between CI615 3BHT300024R1 and CI610 3BHT300003R1?
A: The CI615 3BHT300024R1 is installed at the controller (master station), whereas the CI610 3BHT300003R1 is installed at the remote I/O station.

Q: Does the CI615 3BHT300024R1 support redundancy?
A: Yes. The CI615 3BHT300024R1 can be configured redundantly to enhance the reliability of critical system communications.

Q: Why does the system display a "Communication Supervision" error for the CI615 3BHT300024R1?
A: This error indicates that the CI615 3BHT300024R1 has detected abnormal bus communication, usually caused by external interference, loose cables, or a power failure at the remote CI610 3BHT300003R1.

Q: Are there any special cable requirements when installing the CI615 3BHT300024R1?
A: Yes. Dedicated cables such as TK612 must be used, with optimized impedance and length. Using ordinary shielded cables may lead to communication instability with the CI615 3BHT300024R1.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop