Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
bently nevada 146054 034 20 02 05 ceramic capped probe-0

For Bently Nevada

Home >  Products >  For Bently Nevada

Bently Nevada 146054-034-20-02-05 3300 Ceramic Capped Probe

Manufacturer: Bently Nevada
Product Family: 3300 Ceramic Capped Probe
Product Type: Proximity Probe
Article Number: 146054-034-20-02-05

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview
BENTLY NEVADA • 3300 CERAMIC CAPPED PROBE

146054-034-20-02-05 Proximity Probe

Official Bently Nevada ordering-code interpretation and specifications for 146054-034-20-02-05.

At a Glance

Ordering Code 146054-034-20-02-05
Manufacturer Bently Nevada
Product Family 3300 Ceramic Capped Probe
Product Type Forward-Mount Proximity Probe
Probe Thread 3/8-24 UNF
Total Length 2.0 m (6.6 ft)
Exact CodeVerify every field: 034 case length, 20 total length, 02 connector and 05 approvals.
Harsh EnvironmentsAlumina ceramic tip and AISI 304 stainless steel case support corrosive and high-pressure applications.
System MatchUse with the compatible 8 mm 3300 XL Proximitor Sensor and extension cable specified by Bently Nevada.
Product Overview

146054-034-20-02-05 is a Bently Nevada 3300 Ceramic Capped Probe with a 3/8-24 UNF forward-mount thread and without armor.

The official code resolves as 3.4 in overall case length, 2.0 m total probe length, miniature coaxial ClickLoc connector with standard cable, and the 05 agency-approval option.

Bently Nevada developed this ceramic-capped design for applications where the front of the probe case is exposed to corrosive gases or liquids. The ceramic-to-metal front interface is helium leak tested.

Ordering focus: verify the complete code and installed configuration before quotation or replacement.
Key Functions

Probe Tip

Alumina ceramic (Al₂O₃).

Probe Case

AISI 304 stainless steel.

Linear Range

1.52 mm (60 mils), approximately 0.25 to 1.78 mm from the target.

Recommended Gap

1.0 mm (40 mils); gap electrically and avoid mechanical contact with the target.

Cable

75 Ω coaxial FEP-insulated standard probe cable.

Pressure Capability

Official product information rates the ceramic-capped probe to 34 bar (500 psi); higher-pressure modifications are available.

Official Specifications
Manufacturer Bently Nevada, a Baker Hughes business
Ordering Code 146054-034-20-02-05
Base Probe 146054, 3/8-24 UNF, without armor
Overall Case Length Option 034 = 3.4 in
Total Length Option 20 = 2.0 m (6.6 ft)
Connector / Cable Option 02 = Miniature coaxial ClickLoc connector, standard cable
Agency Approval Option 05 = CSA, ATEX, IECEx
Probe Tip Material Alumina ceramic (Al₂O₃)
Probe Case Material AISI 304 stainless steel
Linear Range 1.52 mm (60 mils)
Recommended Gap 1.0 mm (40 mils)
Cable Type 75 Ω coaxial, FEP insulated
Thread Engagement Limit 0.563 in maximum for 3/8-24 thread
Official Document 3300 Ceramic Capped Probe Datasheet 172932 Rev. J
Official source: technical statements on this page are limited to the manufacturer documents named above. Commercial stock, warranty and shipping terms must be confirmed separately.
Frequently Asked Questions

What is 146054-034-20-02-05?

It is a Bently Nevada 3300 Ceramic Capped forward-mount proximity probe with a 3/8-24 UNF thread and a fully specified ordering configuration.

What does 034 mean in the ordering code?

For probe 146054, option 034 specifies a 3.4 in overall case length.

What does the 20 option specify?

Option 20 specifies a 2.0 m (6.6 ft) total probe length.

Which connector does this probe use?

Option 02 is the miniature coaxial ClickLoc connector with standard cable.

What approvals are represented by 05?

The official ordering table identifies 05 as the CSA, ATEX and IECEx agency-approval option.

Why is the probe ceramic capped?

Bently Nevada designed the ceramic front end for exposure to corrosive gases or liquids; the ceramic-to-metal interface is helium leak tested.

How should the probe be gapped?

The official recommended setting is 1.0 mm (40 mils). Gap electrically and avoid contact between the ceramic tip and the target.

Which official document covers this code?

Baker Hughes/Bently Nevada Datasheet 172932 Rev. J contains the specifications and ordering table for probe 146054.

Compatibility & Ordering Notes
Before ordering 146054-034-20-02-05: compare the complete part number, physical configuration and required approvals with the installed equipment documentation.

Compatibility Checklist

  • Match the complete code 146054-034-20-02-05; each field changes a physical or approval configuration.
  • Confirm 3.4 in case length and 2.0 m total length against the installed geometry.
  • Observe the official 0.563 in maximum thread-engagement limit for the 3/8-24 thread.
  • Gap the probe electrically to 1.0 mm and avoid direct mechanical load on the ceramic tip.
  • Verify ClickLoc connector compatibility and required site approvals before installation.
Hot Selling Models
ABB AI880A 3BSE039293R1
H3W4GR1Y 4MP
EC3-X33 PCN 807 783
IPC241ER5
500101/05
Brady 76706
512 20HPA
Spinner 01 Bn 766436
Tridonic 24138990
STS10598 II1 / 2G
Vbbc3
2099A - G3SKMEM
XLS-REL 3100321
TPS-6X-WS
51196989-100/124662-1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.