SIEMENS · HOG 10 + FSL
HOG10 DN 1024 I,FSL 1050 HOG 10 Incremental Encoder with FSL 1050 rpm Centrifugal Switch
This HOG 10 combination provides 1024-pulse incremental feedback with an integrated FSL centrifugal switch factory-set for 1050 rpm.
At a Glance
| Brand | Baumer |
|---|---|
| Model | HOG10 DN 1024 I,FSL 1050 |
| Product Type | heavy-duty incremental encoder with centrifugal speed switch |
| Core Function | Provides incremental shaft feedback and mechanical overspeed switching in one assembly |
| Application or Compatible Series | Heavy-duty motor and generator feedback systems using the HOG 10 + FSL platform |
Exact Identification
Match HOG10 DN 1024 I,FSL 1050 character by character and confirm the complete HOG 10 Incremental Encoder with FSL 1050 rpm Centrifugal Switch designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
This HOG 10 combination provides 1024-pulse incremental feedback with an integrated FSL centrifugal switch factory-set for 1050 rpm.
The assembly integrates optical incremental sensing with an independent mechanical centrifugal switching function. The I output version uses an HTL power line driver with inverted signals and supports long industrial cable runs. Hybrid bearings, IP66 protection and high shock and vibration resistance support demanding rotating-machine installations.
Key Functions
Encoder and Speed Switch Combination
The assembly integrates optical incremental sensing with an independent mechanical centrifugal switching function.
Long-Distance HTL Signaling
The I output version uses an HTL power line driver with inverted signals and supports long industrial cable runs.
Heavy-Duty Mechanical Design
Hybrid bearings, IP66 protection and high shock and vibration resistance support demanding rotating-machine installations.
Official Specifications
| Pulse Resolution | 1024 pulses per revolution |
|---|---|
| Voltage Supply and Output Stage | 9 to 30 V DC with HTL output and inverted signals |
| FSL Factory Switching Speed | 1050 rpm |
| FSL Speed-Code Range | 950 to 1099 rpm at a 2 rpm/s speed ramp |
| No-Load Current Consumption | 100 mA maximum |
| Phase Shift | 90° ±20° |
| Duty Cycle | 40% to 60% |
| Reference Signal | Zero pulse with 90° width |
| Maximum Standard Output Frequency | 120 kHz |
| Encoder Output Signals | K1, K2 and K0 plus inverted signals |
| Centrifugal-Switch Accuracy | ±4% at 2 rpm/s; 20% at 1500 rpm/s |
| Switching Direction Deviation | 3% maximum between clockwise and counterclockwise rotation |
| Switching Hysteresis | 40% of switching speed |
| Speed-Switch Outputs | 1 speed-controlled output |
| Output Switching Capacity | 6 A at 230 V AC maximum or 1 A at 125 V DC maximum |
| Minimum Switching Current | 50 mA |
| Degree of Protection | IP66 |
| Typical Operating Torque | 6 Ncm |
| Vibration and Shock Resistance | 5 g from 10 to 2000 Hz; 50 g for 11 ms |
| Encoder and Switch Connections | 2 terminal boxes; 3 with redundant-sensing option |
Frequently Asked Questions
Is the FSL switch in HOG10 DN 1024 I,FSL 1050 factory-set to 1050 rpm?
Yes, that switching speed must be specified as the factory setting for the appropriate 950 to 1099 rpm FSL code range.
Which supply and receiver input suit HOG10 DN 1024 I,FSL 1050?
Use a 9 to 30 V DC supply and an input compatible with HTL signals and their inverted channels.
How far can I transmit the encoder signal from HOG10 DN 1024 I,FSL 1050?
The HTL-P version supports up to 350 m at 100 kHz when the specified cable and wiring practices are used.
What load can the speed-switch contact of HOG10 DN 1024 I,FSL 1050 control?
The contact is rated up to 6 A at 230 V AC or 1 A at 125 V DC within the stated regional restrictions.
Can HOG10 DN 1024 I,FSL 1050 be used as a continuously cycling switch?
No, the positive-break centrifugal mechanism is not intended for more than 500 switching cycles over its service life.
Which shaft arrangement must be matched for HOG10 DN 1024 I,FSL 1050?
Use the installed blind-hollow or cone-shaft geometry together with the corresponding torque arm and mounting hardware.
What should be checked before replacing HOG10 DN 1024 I,FSL 1050?
Confirm the pulse count, HTL interface, shaft geometry, sealing system, rotation direction, terminal wiring and 1050 rpm switch setting.
Compatibility & Ordering Notes
Compatibility Checklist
- Match the ordered shaft diameter, sealing system and torque-arm arrangement to the installed machine.
- Use a receiver that accepts the specified HTL incremental and inverted output channels.
- Treat 1050 rpm as the required factory-set switching speed within the corresponding FSL ordering range.