Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
ai910n 3kde175513l9100analog input module-0

For ABB

Home >  Products >  For ABB

AI910N 3KDE175513L9100 Analog Input Module

  • Overview
  • Specifications
  • Description
  • Environment and certification
  • Applications
  • Features and benefits
  • Maintenance
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

AI910N 3KDE175513L9100

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Product Name:

Analog Input Module

Model Number:

AI910N 3KDE175513L9100

Dimensions:

2 x 10.5 x 11 cm

Weight:

0.12 kg

Number of Channels:

4

Signal Type:

4…20 mA

HART Support:

No

SOE:

N/A

Redundancy:

No

Intrinsic Safety:

No

Mechanics:

S900

Description

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced.

The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.

S900 I/O type N. For installation in safe (= non-hazardous) area. AI910N 3KDE175513L9100 Analog Input (AI4), input and power supply for 4...20 mA loop powered 2-wire transmitters.

Environment and certification

Product Name:

Analog Input Module

Model Number:

AI910N 3KDE175513L9100

Dimensions:

2 x 10.5 x 11 cm

Weight:

0.12 kg

Number of Channels:

4

Signal Type:

4…20 mA

HART Support:

No

SOE:

N/A

Redundancy:

No

Intrinsic Safety:

No

Mechanics:

S900

CE Mark:

Yes

Corrosive Atmosphere:

ISA-S71.04 G3

Climatic Operating Conditions:

Relative humidity max. 93 % ± 3 % at 40 °C

Maximum Ambient Temperature:

-20 °C to +60 °C

RoHS Compliance:

DIRECTIVE/2011/65/EU (EN 50581:2012)

WEEE Compliance:

DIRECTIVE/2012/19/EU

WEEE Category:

Small Equipment (No External Dimension More Than 50 cm)

Applications

Oil refineries: Intrinsically safe transmitter access in flammable and explosive pump areas and storage tank areas.

Offshore oil production plants: Signal acquisition in high-concentration oil and gas risk areas on oil production platforms.

Fine chemical plants: Instrument monitoring in explosion-proof areas such as around reactors and solvent storage facilities.

Natural gas compression plants: Pressure control at the junctions of compressor units and gas pipelines.

Pharmaceutical raw material plants: Process parameter feedback for centrifuges and filters in explosion-proof workshops.

Specialty gas plants: Pressure and temperature monitoring at high-purity flammable gas filling stations.

Features and benefits

Redundancy (Power and Communication)

Hot Configuration in Run

Hot Swap functionality

Extended Diagnostic

Excellent configuration and diagnostics via FDT/DTM

G3 – coating for all components

Simplified maintenance with auto-diagnostics

Power supply for 4...20 mA loop powered 2-wire transmitters

Short and break detection

Electrical isolation between input / bus and input / power

Common return for all inputs

4 channels

Maintenance

Hot Swap: Supports hot-swapping of modules during operation without interrupting the mains voltage or affecting communication with other modules.

Automatic Diagnostics: Built-in automatic diagnostic mechanism simplifies daily inspections and troubleshooting.

Hot Configuration in Run (HCIR): Supports modifying configuration parameters while the system is running (Hot Configuration in Run).

FAQ

Q: What is the AI910N 3KDE175513L9100?
A: It is a Analog Input Module.

Q: Does the AI910N 3KDE175513L9100 support HART?
A: No. The AI910N 3KDE175513L9100 does not support HART communication. If HART functionality is required, modules like the AI930 from the same series or other HART-compatible modules should be used.

Q: What is the difference between the AI910N and AI910S?
A: The AI910N (3KDE175513L9100) is designed for standard security zones, while the AI910S (3KDE175511L9100) is intrinsically safe (Ex certified) and suitable for use in hazardous Zone 1 areas.

Q: How to Check Price and Availability for AI910N 3KDE175513L9100?
A: Please contact John Yang for sales at +86-18150117685 or request a quote.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.