Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

AI845-EA 3BSE023675R2

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Model:

AI845-EA 3BSE023675R2

Type:

Analog Input Module

Dimensions:

16 x 15.5 x 8 cm

Weight:

0.34 kg

Resolution:

12-bit

Input Impedance:

10 MΩ (voltage), 250 Ω (current)

Isolation:

Groupwise isolated from ground

Input Range Behavior:

0 / +15% (0–20 mA, 0–5 V), -12.5% / +15% (4–20 mA, 1–5 V)

Accuracy:

Max. 0.1%

Temperature Drift:

Max. 50 ppm/°C

Input Filter (Rise Time 0–90%):

290 ms

Update Cycle Time:

10 ms

Current Limiting:

Built-in transmitter power limiting

Max Field Cable Length:

600 m (656 yards)

Max Input Voltage (Non-destructive):

11 VDC

NMRR (50/60 Hz):

>40 dB

Rated Insulation Voltage:

50 V

Dielectric Test Voltage:

500 VAC

Power Dissipation:

3.5 W

Current Consumption (+5V Modulebus):

100 mA

Current Consumption (+24V Modulebus):

50 mA

Current Consumption (+24V External):

Max. 265 mA

Electrical Safety:

EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201

Hazardous Area Certification:

Class I Div 2, Zone 2 (cULus, ATEX)

Marine Certification:

BV, DNV, LR

Operating Temperature:

0°C to +55°C

Storage Temperature:

-40°C to +70°C

Pollution Degree:

Degree 2 (IEC 60664-1)

Corrosion Protection:

ISA-S71.04 G3

Relative Humidity:

5–95% (non-condensing)

Max Ambient Temperature:

55°C (40°C for vertical mounting in compact MTU)

Protection Class:

IP20 (IEC 60529)

Mechanical Conditions:

IEC/EN 61131-2

EMC:

EN 61000-6-4, EN 61000-6-2

Overvoltage Category:

IEC/EN 60664-1, EN 50178

Equipment Class:

Class I (IEC 61140)

Description

The AI845-EA 3BSE023675R2 Analog Input Module for single or redundant applications. The module has 8 channels. Each channel can be either a voltage or current input when MTU TU844 or TU845 is used, when other MTUs are used all channels become voltage or current inputs. The voltage and current input is able to withstand an overvoltage or undervoltage of at least 11 V d.c. The input resistance for voltage input is greater than 10 M ohm and the input resistance for current input is 250 ohm. The module distributes the external HART compatible transmitter supply to each channel. This adds a simple connection to distribute the supply to 2-wire or 3-wire transmitters. The transmitter power is supervised and current limited.

Applications

Petrochemical plants: HART data acquisition and redundant monitoring of reactor pressure and level transmitters.

Offshore oil production facilities (platforms): Safety monitoring of critical oil and gas pipelines in harsh environments.

Natural gas processing plants: Precision signal processing for gas booster stations and desulfurization processes.

Fine chemical production plants: High-value feedstock proportioning control and process safety instrumented systems (SIS).

Nuclear power plants: Redundant parameter acquisition and equipment status diagnostics for auxiliary systems.

Pharmaceutical distillation plants: HART smart instrument integration in high-purity extraction processes.

Features and benefits

8 channels for 0...20 mA, 4...20 mA, 0...5 V or 1...5 V d.c., single ended unipolar inputs

Single or redundant operation

1 group of 8 channels isolated from ground

12 Bit resolution

Current limited transmitter supply per channel

Advanced on-board diagnostics

HART pass-through communication

Diagnostics

1 Front LED’s : F(ault), R(un), W(arning)

2 Supervision:

Module error: analog read back, reference voltage, internal power supply, checksum, watchdog and memory error

Internal channel error: low pass filter´, multiplexer, test channel error

External channel error: external power supply low, transmitter power, external shunt error

3 Status indication of supervision :Module Error, Module Warning, Channel error

FAQ

Q: What is the AI845-EA 3BSE023675R2?
A: It is a Analog Input Module.

Q: What is the difference between AI845-EA and AI845?
A: AI845-EA (with the -EA suffix) is a version optimized for Essential Automation systems. It is functionally and performance-wise essentially the same as the standard AI845, but is better suited for specific system architectures or project configurations. In practice, they are often interchangeable, but confirmation is needed based on the system version and project configuration.

Q: Does AI845-EA 3BSE023675R2 support hot-swap?
A: Yes. As a member of the S800 I/O series, this module supports hot-swap functionality, allowing module replacement without power interruption. However, in non-redundant configurations, it is recommended to verify the system's safety status and interlocking conditions before operation to avoid impacting process control.

Q: How to Check Price and Availability for AI845-EA 3BSE023675R2?
A: Please contact John Yang for sales at +86-18150117685 or request a quote.

Get a Free Quote